Validation of 3-dimensional mathematical computation of feline bladder volume using orthogonal ultrasonographic bladder images

被引:0
|
作者
Yang, Chien Hsien Kitty [1 ]
Bateman, Shane W. [1 ]
Yiew, Xiu Ting [1 ]
Willms, Allan R. [2 ]
机构
[1] Univ Guelph, Dept Clin Studies, Ontario Vet Coll, 50 Stone Rd East, Guelph, ON N1G 2W1, Canada
[2] Univ Guelph, Dept Math & Stat, Coll Engn & Phys Sci, 50 Stone Rd East, Guelph, ON N1G 2W1, Canada
来源
CANADIAN JOURNAL OF VETERINARY RESEARCH-REVUE CANADIENNE DE RECHERCHE VETERINAIRE | 2022年 / 86卷 / 03期
关键词
ACCURACY; IMPACT; SHAPE; CATS; DOGS;
D O I
暂无
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Urine output measurement is critical for the management of hospitalized cats and their underlying conditions. Ultrasoundguided estimation of urinary bladder volume (UBV) is a non-invasive surrogate measurement that can provide important clinical information. The purpose of this study was to validate the accuracy of a novel 3D computation method in estimating UBV using 2D point-of- care ultrasonographic images. Bladder volume estimation was performed using coordinates from bladder circumference tracings on paired longitudinal and transverse ultrasonographic images (n = 359) aligned in 3D space for mathematical algorithmic computation. Ultrasonographic images were obtained by 2 different observers at 18 different time points on 10 healthy, purpose-bred male cats under general anesthesia in sternal recumbency. Actual urine volumes were measured via urinary catheterization and compared to UBV estimations using Lin's concordance correlation coefficient and Bland-Altman analysis. Estimation of UBV using the 3D computational bladder circumference tracing method showed moderate strength- of-agreement with actual bladder volume (p(c) = 0.94 to 0.95) with clinically insignificant bias (3D computation-derived minus actual volume) of 21.96 mL (IQR = 23.89 to 20.57 mL, P, 0.001) and 22.42 mL (IQR = 24.64 to 20.66 mL, P, 0.001) for the 2 observers, respectively. Our study demonstrated acceptable accuracy of 3D computation method for UBV estimation in healthy cats. This method may provide a bridging alternative until 3D ultrasound becomes more readily accessible.
引用
收藏
页码:209 / 217
页数:9
相关论文
共 50 条
  • [21] PRODUCTION OF 3-DIMENSIONAL IMAGES BY USING SELECTOGRAMS
    DENISYUK, YN
    OPTIKA I SPEKTROSKOPIYA, 1995, 78 (05): : 832 - 836
  • [22] THE COMPUTATION OF 3-DIMENSIONAL FLOWS USING UNSTRUCTURED GRIDS
    MORGAN, K
    PERAIRE, J
    PEIRO, J
    HASSAN, O
    COMPUTER METHODS IN APPLIED MECHANICS AND ENGINEERING, 1991, 87 (2-3) : 335 - 352
  • [23] In vivo three-dimensional sonographic measurement of organ volume: Validation in the urinary bladder
    Riccabona, M
    Nelson, TR
    Pretorius, DH
    Davidson, TE
    JOURNAL OF ULTRASOUND IN MEDICINE, 1996, 15 (09) : 627 - 632
  • [24] In vivo three-dimensional sonographic measurement of organ volume: Validation in the urinary bladder
    Department of Radiology, University of California, San Diego, San Diego, CA, United States
    不详
    J. ULTRASOUND MED., 9 (627-632):
  • [25] Reconstruction of 3-dimensional right ventricular shape and volume from 3 orthogonal planes
    Munoz, R
    Marcus, E
    Palacio, G
    Gauvreau, K
    Wessel, DL
    Colan, SD
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2000, 13 (03) : 177 - 185
  • [26] LUMINAL PLASMA MEMBRANE OF URINARY BLADDER .1. 3-DIMENSIONAL RECONSTRUCTION FROM FREEZE-ETCH IMAGES
    STAEHELIN, LA
    CHLAPOWSKI, FJ
    BONNEVILLE, MA
    JOURNAL OF CELL BIOLOGY, 1970, 47 (02): : A200 - +
  • [27] MEASUREMENT OF FELINE BLADDER PRESSURE AND VOLUME USING CATHETER-FREE WIRELESS INTRAVESICAL SENSOR
    Majerus, S.
    Deng, K.
    Hanzlicek, B.
    Panda, B.
    Mrowca, J.
    Bourbeau, D.
    Damaser, M.
    NEUROUROLOGY AND URODYNAMICS, 2020, 39 : S232 - S234
  • [28] MEASUREMENT OF FELINE BLADDER PRESSURE AND VOLUME USING CATHETER-FREE WIRELESS INTRAVESICAL SENSOR
    Damaser, Margot
    Majerus, Steve
    Bourbeau, Dennis
    Cabal, Dario
    Hanzlicek, Brett
    Elazab, Mohamed
    NEUROUROLOGY AND URODYNAMICS, 2023, 42 : S7 - S8
  • [29] Pelvic floor anatomy in classic bladder exstrophy using 3-dimensional computerized tomography: Initial insights
    Stec, AA
    Pannu, HK
    Tadros, YE
    Sponseller, PD
    Fishman, EK
    Gearhart, JP
    JOURNAL OF UROLOGY, 2001, 166 (04): : 1444 - 1449
  • [30] Functional genomics of phenotypic switching of bladder cancer cells in 3-dimensional culture
    Hurst, RE
    Kyker, KD
    Hemstreet, GP
    JOURNAL OF UROLOGY, 2002, 167 (04): : 117 - 117