Jones matrix-based speckle-decorrelation angiography using polarization-sensitive optical coherence tomography

被引:14
作者
Gong, Peijun [1 ]
Li, Qingyun [1 ]
Wang, Qiang [1 ]
Karnowski, Karol [1 ,2 ]
Sampson, David D. [3 ,4 ]
机构
[1] Univ Western Australia, Dept Elect Elect & Comp Engn, Opt Biomed Engn Lab, Perth, WA, Australia
[2] Polish Acad Sci, Inst Phys Chem, Warsaw, Poland
[3] Univ Surrey, Surrey Biophoton Adv Technol Inst, Guildford, Surrey, England
[4] Univ Surrey, Sch Biosci & Med, Guildford, Surrey, England
关键词
angiography; Jones matrix; polarization-sensitive optical coherence tomography; skin microvasculature; speckle decorrelation; AXIS ORIENTATION; HUMAN SKIN; BIREFRINGENCE; SCATTERING;
D O I
10.1002/jbio.202000007
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We show that polarization-sensitive optical coherence tomography angiography (PS-OCTA) based on full Jones matrix assessment of speckle decorrelation offers improved contrast and depth of vessel imaging over conventional OCTA. We determine how best to combine the individual Jones matrix elements and compare the resulting image quality to that of a conventional OCT scanner by co-locating and imaging the same skin locations with closely matched scanning setups. Vessel projection images from finger and forearm skin demonstrate the benefits of Jones matrix-based PS-OCTA. Our study provides a promising starting point and a useful reference for future pre-clinical and clinical applications of Jones matrix-based PS-OCTA.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Melanin concentration and depolarization metrics measurement by polarization-sensitive optical coherence tomography
    Yamanari, Masahiro
    Mase, Mutsuki
    Obata, Ryo
    Matsuzaki, Mitsuhiro
    Minami, Takahiro
    Takagi, Seiji
    Yamamoto, Motoshi
    Miyamoto, Noriko
    Ueda, Koji
    Koide, Naoshi
    Maeda, Tadao
    Totani, Kota
    Aoki, Nobuyori
    Hirami, Yasuhiko
    Sugiyama, Satoshi
    Mandai, Michiko
    Aihara, Makoto
    Takahashi, Masayo
    Kato, Satoshi
    Kurimoto, Yasuo
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [32] Measurement of Multiple Optical Parameters of Birefrigent Sample Using Polarization-Sensitive Optical Coherence Tomography
    Liao, Chia-Chi
    Lo, Yu-Lung
    Yeh, Cheng-Yen
    JOURNAL OF LIGHTWAVE TECHNOLOGY, 2009, 27 (5-8) : 483 - 493
  • [33] In vivo analysis of human skin anisotropy by polarization-sensitive optical coherence tomography
    Sakai, Shingo
    Yamanari, Masahiro
    Lim, Yiheng
    Makita, Shuichi
    Nakagawa, Noriaki
    Yasuno, Yoshiaki
    PHOTONIC THERAPEUTICS AND DIAGNOSTICS VII, 2011, 7883
  • [34] Mapping local optical axis in birefringent samples using polarization-sensitive optical coherence tomography
    Fan, Chuanmao
    Yao, Gang
    JOURNAL OF BIOMEDICAL OPTICS, 2012, 17 (11)
  • [35] Endoscopic imaging of the human vocal cords using polarization-sensitive optical coherence tomography
    Pierce, MC
    Klein, A
    Burns, JA
    Shishkov, M
    Park, BH
    Tearney, GJ
    Bouma, BE
    Zeitels, SM
    de Boer, JF
    Photonic Therapeutics and Diagnostics, 2005, 5686 : 307 - 309
  • [36] Burn depth determination in human skin using polarization-sensitive optical coherence tomography
    Pierce, MC
    Sheridan, RL
    Park, BH
    Cense, B
    de Boer, JF
    COHERENCE DOMAIN OPTICAL METHODS AND OPTICAL COHERENCE TOMOGRAPHY IN BIOMEDICINE VII, 2003, 4956 : 263 - 270
  • [37] Correcting Optical-Axis Calculation in Polarization-Sensitive Optical Coherence Tomography
    Fan, Chuanmao
    Yao, Gang
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2010, 57 (10) : 2556 - 2559
  • [38] Cartilage disease diagnosis by conventional and polarization-sensitive optical coherence tomography
    Xie, TQ
    Guo, SG
    Rao, B
    Chen, ZP
    Peavy, GM
    Coherence Domain Optical Methods and Optical Coherence Tomography in Biomedicine IX, 2005, 5690 : 556 - 562
  • [39] Polarization-sensitive optical coherence tomography with de-correlated channels
    Zaatari, HN
    Kemp, NJ
    Akkin, T
    Rylander, HG
    Milner, TE
    COHERENCE DOMAIN OPTICAL METHODS AND OPTICAL COHERENCE TOMOGRAPHY IN BIOMEDICINE VIII, 2004, 5316 : 360 - 364
  • [40] Spectroscopic polarization-sensitive full-field optical coherence tomography
    Dubois, Arnaud
    OPTICS EXPRESS, 2012, 20 (09): : 9962 - 9977