A simulation study for the design of a prototype insert for whole-body PET scanners

被引:25
作者
Janecek, Martin [1 ]
Wu, Heyu [1 ]
Tai, Yuan-Chuan [1 ]
机构
[1] Washington Univ, Mallinckrodt Inst Radiol, St Louis, MO 63110 USA
基金
美国国家卫生研究院;
关键词
depth of interaction (DOI); head and neck imaging; high resolution imaging; Monte Carlo simulations; pseudo pinhole positron emission tomography (PET);
D O I
10.1109/TNS.2006.871899
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We are developing an insert device that will improve image resolution within a smaller field-of-view for clinical whole-body PET scanners. We modified SimSET (Simulation System for Emission Tomography) to simulate the insert and a PET scanner. The system consists of two detector rings. The inner ring represents an insert (r = 153 mm) with high-resolution detectors using 10 min thick LSO. The outer ring represents a PET scanner (R = 413 mm) with 25 mm thick LSO. Events were binned into three sets of sinograms assuming a 2.4 and 6.75 min crystal-pitch for the insert and the PET scanner, respectively. The detectors in the insert are modeled as 1, 2, or 4 layers with different offset configurations to evaluate the corresponding system resolution with the depth-of-interaction (DOI) effect. Results show that image resolution at I cm radial offset is improved from 5.6 min full-width-at-half-maximum (FWHM) of the original PET scanner to 2.0 min with the insert. At 12 cm offset, the resolution of the original system is 5.9 and 5.5 min for radial and tangential directions, respectively. With the insert, the radial resolution is 5.0 mm FWHM for a single-layer detector design, but improves to 2.7 and 2.2 mm for 2- and 4-layer DOI detectors, respectively. Different offsets for multi-layer detectors have negligible effect on resolution. Sensitivity of the device is, assuming the insert has a 2 cm axial extend, estimated to be 3.3%, including coincidence events from the insert-alone and insert-to-scanner sinograms. In contrast, if the insert is used as a stand-alone microPET scanner, its sensitivity is 1.3%.
引用
收藏
页码:1143 / 1149
页数:7
相关论文
共 19 条
[1]  
CLINTHORNE NH, IEEE NUCL SCI S C RE
[2]   maxPET: A dedicated mammary and axillary region PET imaging system for breast cancer [J].
Doshi, NK ;
Silverman, RW ;
Shao, Y ;
Cherry, SR .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (03) :811-815
[3]  
Freifelder R, 2002, IEEE NUCL SCI CONF R, P1241, DOI 10.1109/NSSMIC.2001.1008560
[4]  
HARRISON R, 2002, IEEE MED IM C NORF V
[5]   Development of the LBNL positron emission mammography camera [J].
Huber, JS ;
Choong, WS ;
Wang, J ;
Maltz, JS ;
Qi, J ;
Mandelli, E ;
Moses, WW .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2003, 50 (05) :1650-1653
[6]   Conceptual design of a compact positron tomograph for prostate imaging [J].
Huber, JS ;
Derenzo, SE ;
Qi, J ;
Moses, WW ;
Huesman, RH ;
Budinger, TF .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (04) :1506-1511
[7]  
LECOMTEFINIGER R, 2001, ATOLL RES B, V486, P1
[8]   Positron emission mammographic instrument: Initial results [J].
Murthy, K ;
Aznar, M ;
Bergman, AM ;
Thompson, CJ ;
Robar, JL ;
Lisbona, R ;
Loutfi, A ;
Gagnon, JH .
RADIOLOGY, 2000, 215 (01) :280-285
[9]  
PARK S, 2002, IEEE NUCL SCI S C RE
[10]   Lutetium oxyorthosilicate block detector readout by avalanche photodiode arrays for high resolution animal PET [J].
Pichler, BJ ;
Swann, BK ;
Rochelle, J ;
Nutt, RE ;
Cherry, SR ;
Siegel, SB .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (18) :4305-4319