Balloon-Assisted Tracking: A Must-Know Technique to Overcome Difficult Anatomy During Transradial Approach

被引:65
作者
Patel, Tejas [1 ,2 ,3 ]
Shah, Sanjay [1 ,2 ,3 ]
Pancholy, Samir [4 ,5 ]
Rao, Sunil [6 ]
Bertrand, Olivier F. [7 ]
Kwan, Tak [8 ]
机构
[1] Apex Heart Inst, Ahmadabad 380054, Gujarat, India
[2] Sheth VS Gen Hosp, Dept Cardiol, Ahmadabad 380006, Gujarat, India
[3] Smt NHL Municipal Med Coll, Ahmadabad 380006, Gujarat, India
[4] Mercy Hosp, Dept Cardiol, Scranton, PA USA
[5] Community Med Ctr, Scranton, PA USA
[6] Duke Univ, Med Ctr, Durham, NC USA
[7] Quebec Heart Lung Inst, Quebec City, PQ, Canada
[8] NYU Sch Med, New York, NY USA
关键词
radial artery; balloon-assisted tracking; coronary angiography; coronary intervention; PERCUTANEOUS CORONARY INTERVENTION; FEASIBILITY;
D O I
10.1002/ccd.24959
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
ObjectiveTo examine the use and outcomes of balloon-assisted tracking (BAT) technique for dealing with complexities of arm and chest vasculature during transradial approach (TRA) at a single high volume radial center. BackgroundTRA has been used for coronary angiography and percutaneous coronary interventions (PCI) around the world. Different techniques have been described to address the anatomical issues and tortuosities for successful completion of coronary angiography and PCI. This study describes the use of BAT technique and associated outcomes during real world clinical practice. MethodsSubjects comprised 63 patients, (out of total 8,245 patients between January 2011 and December 2012) in whom we encountered significantly complex anatomical course in radial, brachial, or subclavian region, leading to difficult advancement of a diagnostic or a guide catheter despite trying all standard maneuvers. In all of them BAT technique was used and they were retrospectively analyzed for the purpose of this study. ResultsAbout 63 (0.76%) of 8,245 patients met the study criteria. Twenty-five (39.7%) patients had very small RA. Twenty-two (34.9%) had severe RA tortuosity. Four (6.3%) had complex RA loops. Six (9.5%) had severe RA spasm and six (9.5%) had severe subclavian tortuosity and/or stenosis. We encountered technical failure in three (4.8%) patients (two had very small RA and one had 360 degree RA loop). ConclusionBAT technique was useful to address the anatomical issues and tortuosities of radial, brachial, and subclavian vasculature during TRA. (c) 2013 Wiley Periodicals, Inc.
引用
收藏
页码:211 / 220
页数:10
相关论文
共 17 条
[1]   Transradial access for primary percutaneous coronary intervention: the next standard of care? [J].
Amoroso, Giovanni ;
Kiemeneij, Ferdinand .
HEART, 2010, 96 (17) :1341-1344
[2]   Radial loop and extreme vessel tortuosity in the transradial approach: advantage of hydrophilic-coated guidewires and catheters [J].
Barbeau, GR .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2003, 59 (04) :442-450
[3]  
Bazemore Elizabeth, 2005, J Invasive Cardiol, V17, P156
[4]   Mechanism and Predictors of Failed Transradial Approach for Percutaneous Coronary Interventions [J].
Dehghani, Payam ;
Mohammad, Atif ;
Bajaj, Ravi ;
Hong, Tony ;
Suen, Colin M. ;
Sharieff, Waseem ;
Chisholm, Robert J. ;
Kutryk, Michael J. B. ;
Fam, Neil P. ;
Cheema, Asim N. .
JACC-CARDIOVASCULAR INTERVENTIONS, 2009, 2 (11) :1057-1064
[5]  
Gilchrist IC, 2000, CATHETER CARDIO INTE, V49, P353
[6]  
Ho PC, 2008, J INVASIVE CARDIOL, V20, P222
[7]   Prevention of radial artery occlusion-patent hemostasis evaluation trial (PROPHET study): A randomized comparison of traditional versus patency documented hemostasis after transradial catheterization [J].
Pancholy, Samir ;
Coppola, John ;
Patel, Tejas ;
Roke-Thomas, Marie .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2008, 72 (03) :335-340
[8]  
Patel T, 2012, PATELS ATLAS TRANSRA
[9]   Balloon-assisted tracking of a guide catheter through difficult radial anatomy: A technical report [J].
Patel, Tejas ;
Shah, Sanjay ;
Pancholy, Samir .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2013, 81 (05) :E215-E218
[10]  