A data analysis method for isochronous mass spectrometry using two time-of-flight detectors at CSRe

被引:14
|
作者
Xu Xing [1 ,2 ,3 ,4 ]
Wang Meng [1 ,2 ]
Shuai Peng [5 ,6 ]
Chen Rui-Jiu [1 ,2 ]
Yan Xin-Liang [1 ,2 ]
Zhang Yu-Hu [1 ,2 ]
Yuan You-Jin [1 ,2 ]
Xu Hu-Shan [1 ,2 ]
Zhou Xiao-Hong [1 ,2 ]
Litvinov, Yuri A. [1 ,2 ,7 ]
Litvinov, Sergey [7 ]
Tu Xiao-Lin [1 ,2 ,7 ]
Chen Xiang-Cheng [1 ,2 ,3 ]
Fu Chao-Yi [1 ,2 ,3 ]
Ge Wen-Wen [1 ,2 ,3 ]
Ge Zhuang [1 ,2 ,3 ]
Hu Xue-Jing [1 ,2 ,3 ]
Huang Wen-Jia [1 ,2 ,3 ,4 ]
Liu Da-Wei [1 ,2 ,3 ]
Xing Yuan-Ming [1 ,2 ,3 ]
Zeng Qi [5 ,6 ]
Zhang Wei [1 ,2 ,3 ]
机构
[1] Chinese Acad Sci, Inst Modern Phys, Key Lab High Precis Nucl Spect, Lanzhou 730000, Peoples R China
[2] Chinese Acad Sci, Inst Modern Phys, Ctr Nucl Matter Sci, Lanzhou 730000, Peoples R China
[3] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
[4] Univ Paris 11, CSNSM CNRS IN2P3, F-91405 Orsay, France
[5] Natl Lab Heavy Ion Accelerator Facil Lanzhou, Res Ctr Hadron Phys, Hefei 230026, Peoples R China
[6] Univ Sci & Technol China, Hefei 230026, Peoples R China
[7] GSI Helmholtzzentrum Schwerionenforsch, D-64291 Darmstadt, Germany
关键词
isochronous mass spectrometry; exotic nuclei; two TOF detectors; cooler storage ring; simulation; EXPERIMENTAL STORAGE-RING; LIVED EXOTIC NUCLEI; FRS-ESR FACILITY; RICH NUCLEI; LANZHOU; GSI;
D O I
10.1088/1674-1137/39/10/106201
中图分类号
O57 [原子核物理学、高能物理学];
学科分类号
070202 ;
摘要
The concept of isochronous mass spectrometry (IMS) applying two time-of-flight (TOF) detectors originated many years ago at GSI. However, the corresponding method for data analysis has never been discussed in detail. Recently, two TOP detectors have been installed at CSRe and the new working mode of the ring is under test. In this paper, a data analysis method for this mode is introduced and tested with a series of simulations. The results show that the new IMS method can significantly improve mass resolving power via the additional velocity information of stored ions. This improvement is especially important for nuclides with Lorentz factor gamma-value far away from the transition point gamma t of the storage ring CSRe.
引用
收藏
页数:7
相关论文
共 25 条
  • [1] A data analysis method for isochronous mass spectrometry using two time-of-flight detectors at CSRe
    徐星
    王猛
    帅鹏
    陈瑞九
    颜鑫亮
    张玉虎
    原有进
    徐瑚珊
    周小红
    Yuri A.Litvinov
    Sergey Litvinov
    涂小林
    陈相成
    付超义
    葛文文
    葛壮
    胡雪静
    黄文嘉
    刘大委
    邢元明
    曾奇
    章卫
    Chinese Physics C, 2015, (10) : 107 - 113
  • [2] First isochronous mass measurements with two time-of-flight detectors at CSRe
    Xing, Y. M.
    Wang, M.
    Zhang, Y. H.
    Shuai, P.
    Xu, X.
    Chen, R. J.
    Yan, X. L.
    Tu, X. L.
    Zhang, W.
    Fu, C. Y.
    Xu, H. S.
    Litvinov, Yu A.
    Blaum, K.
    Chen, X. C.
    Ge, Z.
    Gao, B. S.
    Huang, W. J.
    Litvinov, S. A.
    Liu, D. W.
    Ma, X. W.
    Mao, R. S.
    Xiao, G. Q.
    Yang, J. C.
    Yuan, Y. J.
    Zeng, Q.
    Zhou, X. H.
    PHYSICA SCRIPTA, 2015, T166
  • [3] Time-of-flight detectors with improved timing performance for isochronous mass measurements at the CSRe
    Zhang, W.
    Tu, X. L.
    Wang, M.
    Zhang, Y. H.
    Xu, H. S.
    Litvinov, Yu. A.
    Blaum, K.
    Chen, R. J.
    Chen, X. C.
    Fu, C. Y.
    Ge, Z.
    Gao, B. S.
    Hu, Z. G.
    Huang, W. J.
    Litvinov, S. A.
    Liu, D. W.
    Ma, X. W.
    Mao, R. S.
    Mei, B.
    Shuai, P.
    Sun, B. H.
    Xia, J. W.
    Xiao, G. Q.
    Xing, Y. M.
    Xu, X.
    Yamaguchi, T.
    Yan, X. L.
    Yang, J. C.
    Yuan, Y. J.
    Zeng, Q.
    Zhang, X. Y.
    Zhao, H. W.
    Zhao, T. C.
    Zhou, X. H.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2014, 756 : 1 - 5
  • [4] An improvement of isochronous mass spectrometry: Velocity measurements using two time-of-flight detectors
    Shuai, P.
    Xu, X.
    Zhang, Y. H.
    Xu, H. S.
    Litvinov, Yu. A.
    Wang, M.
    Tu, X. L.
    Blaum, K.
    Zhou, X. H.
    Yuan, Y. J.
    Yan, X. L.
    Chen, X. C.
    Chen, R. J.
    Fu, C. Y.
    Ge, Z.
    Huang, W. J.
    Xing, Y. M.
    Zeng, Q.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2016, 376 : 311 - 315
  • [5] A high performance Time-of-Flight detector applied to isochronous mass measurement at CSRe
    Mei, Bo
    Tu, Xiaolin
    Wang, Meng
    Xu, Hushan
    Mao, Ruishi
    Hu, Zhengguo
    Ma, Xinwen
    Yuan, Youjin
    Zhang, Xueying
    Geng, Peng
    Peng Shuai
    Zang, Yongdong
    Tang, Shuwen
    Ma, Peng
    Lu, Wan
    Yan, Xinshuai
    Xia, Jiawen
    Xiao, Guoqing
    Guo, Zhongyan
    Zhang, Hongbin
    Yue, Ke
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 624 (01) : 109 - 113
  • [6] Identification of Time-of-Flight spectra for Isochronous Mass Measurements
    Sun Bao-Hua
    Geissel, H.
    Hausmann, M.
    Kozhuharov, C.
    Knoebel, R.
    Litvinov, Yu A.
    Meng Jie
    Patyk, Z.
    Radon, T.
    Scheidenberger, C.
    CHINESE PHYSICS C, 2009, 33 : 161 - 163
  • [7] Design of a new time-of-flight detector for isochronous mass spectrometry in the collector ring at FAIR
    Diwisch, M.
    Plass, W. R.
    Geissel, H.
    Knoebel, R.
    Kuzminchuk-Feuerstein, N.
    San Andres, S. Ayet
    Dickel, T.
    Scheidenberger, C.
    Weick, H.
    PHYSICA SCRIPTA, 2015, T166
  • [8] Identification of Time-of-Flight spectra for Isochronous Mass Measurements
    孙保华
    H. Geissel
    M. Hausmann
    C. Kozhuharov
    R. Knbel
    Yu.A. Litvinov
    孟杰
    Z. Patyk
    T. Radon
    C. Scheidenberger
    中国物理C, 2009, (S1) : 161 - 163
  • [9] Multiple-reflection time-of-flight mass spectrometry
    Plass, Wolfgang R.
    Dickel, Timo
    Scheidenberger, Christoph
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2013, 349 : 134 - 144
  • [10] Time-of-flight secondary ion mass spectrometry in the helium ion microscope
    Klingner, N.
    Heller, R.
    Hlawacek, G.
    Facsko, S.
    von Borany, J.
    ULTRAMICROSCOPY, 2019, 198 : 10 - 17