Noncontact Distance and Amplitude-Independent Vibration Measurement Based on an Extended DACM Algorithm

被引:178
作者
Wang, Jingyu [1 ]
Wang, Xiang [2 ]
Chen, Lei [3 ]
Huangfu, Jiangtao [1 ]
Li, Changzhi [4 ]
Ran, Lixin [1 ]
机构
[1] Zhejiang Univ, Lab Appl Res Elect, Hangzhou 310027, Zhejiang, Peoples R China
[2] Zhejiang Univ, Sch Med, Hangzhou 310003, Zhejiang, Peoples R China
[3] China Aerosp Sci & Ind Acad Informat Technol, Beijing 100070, Peoples R China
[4] Texas Tech Univ, Dept Elect & Comp Engn, Lubbock, TX 79409 USA
基金
美国国家科学基金会;
关键词
Arctangent demodulation; differentiate and cross multiply (DACM); noncontact vibration measurement; nonlinear phase modulation; radar sensor; HEARTBEAT;
D O I
10.1109/TIM.2013.2277530
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Utilizing microwave continuous-wave Doppler radars to wirelessly detect mechanical vibrations have been attracting more and more interests in recent years. In this paper, aiming to solve the null point and nonlinear issues in small-angle approximation-based Doppler radar sensors and eliminate the codomain restriction in the arctangent demodulation approach, we propose and investigate an extended differentiate and cross-multiply (DACM) algorithm. With an additional accumulator, the noise performance of the original DACM algorithm is improved. Moreover, the amplitude information of the vibration can be directly retrieved from accumulation without involving any distance-dependent issue. Experimental validations show that the proposed algorithm can fully recover the vibration patterns with the measured noncalibrated amplitude agreeing well with the known precalibrated data. Application examples of mechanical fault detection and human vital sign detection are demonstrated, showing a wide range of potential applications of this algorithm.
引用
收藏
页码:145 / 153
页数:9
相关论文
共 20 条
  • [1] [Anonymous], 2011, AG ADV SERV AG 33210
  • [2] [Anonymous], 2011, PROC IEEE GLOBAL TEL
  • [3] A New Measurement Method Based on Music Algorithm for Through-the-Wall Detection of Life Signs
    Ascione, Marcello
    Buonanno, Aniello
    D'Urso, Michele
    Angrisani, Leopoldo
    Lo Moriello, Rosario Schiano
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2013, 62 (01) : 13 - 26
  • [4] Castellini P., 2009, An Introduction to Optoelectronic Sensors, P216
  • [5] Microwave life-detection systems for searching human subjects under earthquake rubble or behind barrier
    Chen, KM
    Huang, Y
    Zhang, JP
    Norman, A
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2000, 47 (01) : 105 - 114
  • [6] Range correlation and I/Q performance benefits in single-chip silicon Doppler radars for noncontact cardiopulmonary monitoring
    Droitcour, AD
    Boric-Lubecke, O
    Lubecke, VM
    Lin, JS
    Kovacs, GTA
    [J]. IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2004, 52 (03) : 838 - 848
  • [7] Eargle J., 2003, LOUDSPEAKER HDB
  • [8] Gao WH, 2007, IEEE WCNC, P2802
  • [9] Gu CZ, 2011, IEEE ENG MED BIO, P417, DOI 10.1109/IEMBS.2011.6090054
  • [10] Instrument-Based Noncontact Doppler Radar Vital Sign Detection System Using Heterodyne Digital Quadrature Demodulation Architecture
    Gu, Changzhan
    Li, Changzhi
    Lin, Jenshan
    Long, Jiang
    Huangfu, Jiangtao
    Ran, Lixin
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2010, 59 (06) : 1580 - 1588