Evaluation of a Tube Voltage-Tailored Contrast Medium Injection Protocol for Coronary CT Angiography: Results From the Prospective VOLCANIC Study

被引:14
作者
Martin, Simon S. [1 ,2 ]
Giovagnoli, Dante A. [1 ]
Abadia, Andres F. [1 ]
Vingiani, Vincenzo [1 ]
Doeberitz, Philipp L. von Knebel [1 ,3 ]
Smith, Hubert E. [1 ]
Fischer, Andreas M. [1 ]
Varga-Szemes, Akos [1 ]
Vogl, Thomas J. [2 ]
De Cecco, Carlo N. [1 ,4 ]
Schoepf, U. Joseph [1 ,5 ]
机构
[1] Med Univ South Carolina, Div Cardiovasc Imaging, Dept Radiol & Radiol Sci, Charleston, SC 29425 USA
[2] Univ Hosp Frankfurt, Dept Diagnost & Intervent Radiol, Frankfurt, Germany
[3] Heidelberg Univ, Univ Med Ctr Mannheim, Med Fac Mannheim, Inst Clin Radiol & Nucl Med, Mannheim, Germany
[4] Emory Univ, Dept Radiol & Imaging Sci, Div Cardiothorac Imaging Nucl Med & Mol Imaging, Atlanta, GA 30322 USA
[5] Med Univ South Carolina, Heart & Vasc Ctr, Ashley River Tower,25 Courtenay Dr, Charleston, SC 29425 USA
关键词
contrast medium; CT angiography; individualized medicine; MDCT; radiation dosage; COMPUTED TOMOGRAPHIC ANGIOGRAPHY; DUAL-SOURCE CT; IMAGE-QUALITY; ITERATIVE RECONSTRUCTION; SELECTION;
D O I
10.2214/AJR.20.22777
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study was to prospectively evaluate, using software support, the feasibility and the quantitative and qualitative image quality parameters of a tube voltage-tailored contrast medium (CM) application protocol for patient-specific injection during coronary CT angiography (CCTA). SUBJECTS AND METHODS. In the Voltage-Based Contrast Media Adaptation in Coronary Computed Tomography Angiography (VOLCANIC-CTA) study, a single-center trial, 120 patients referred for CCTA were prospectively assigned to a tube voltage-tailored CM injection protocol. Automated tube voltage levels were selected in 10-kV intervals and ranged from 70 to 130 kV, and the iodine delivery rate (IDR) was adapted to the tube voltage level using dedicated software. The administered CM volume (370 mg I/mL) ranged from 33 mL at 70 kV (IDR, 0.7 g I/s) to 65 mL at 130 kV (IDR, 1.7 g I/s). Attenuation was measured in the aorta and coronary arteries to calculate quantitative signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR), and 5-point scales were used to evaluate overall image quality. Radiation metrics were also assessed and compared among the protocols. RESULTS. The mean age of the study patients was 62.5 +/- 11.9 (SD) years. Image quality was rated as diagnostic in all patients. Contrast attenuation peaked at 70 kV (p < 0.001), whereas SNR and CNR parameters showed no significant differences between tube voltage levels (p >= 0.085). Additionally, no significant differences in subjective image quality parameters were found among the different protocols (p >= 0.139). The lowest radiation dose values were observed in the group assigned to the 70-kV protocol, which had a median radiation effective dose of 2.0 mSv (p < 0.001). CONCLUSION. The proposed tube voltage-tailored injection protocol allows individualized scanning of patients undergoing CCTA and significantly reduces CM and radiation dose while maintaining a high diagnostic image quality.
引用
收藏
页码:1049 / 1056
页数:8
相关论文
共 27 条
  • [11] Optimization of contrast material administration for electrocardiogram-gated computed tomographic angiography of the chest
    Johnson, Thorsten R. C.
    Nikolaou, Konstantin
    Wintersperger, Bernd J.
    Fink, Christian
    Rist, Carsten
    Leber, Alexander W.
    Knez, Andreas
    Reiser, Maximilian F.
    Becker, Christoph R.
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2007, 31 (02) : 265 - 271
  • [12] Optimizing contrast media application in coronary CT angiography at lower tube voltage: Evaluation in a circulation phantom and sixty patients
    Kok, Madeleine
    Mihl, Casper
    Hendriks, Babs M. F.
    Altintas, Sibel
    Kietselaer, Bas L. J. H.
    Wildberger, Joachim E.
    Das, Marco
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2016, 85 (06) : 1068 - 1074
  • [13] Monoenergetic Dual-energy Computed Tomographic Imaging Cardiothoracic Applications
    Lenga, Lukas
    Albrecht, Moritz H.
    Othman, Ahmed E.
    Martin, Simon S.
    Leithner, Doris
    D'Angelo, Tommaso
    Arendt, Christophe
    Scholtz, Jan-Erik
    De Cecco, Carlo N.
    Schoepf, U. Joseph
    Vogl, Thomas J.
    Wichmann, Julian L.
    [J]. JOURNAL OF THORACIC IMAGING, 2017, 32 (03) : 151 - 158
  • [14] Diagnostic accuracy of coronary CT angiography using 3rd-generation dual-source CT and automated tube voltage selection: Clinical application in a non-obese and obese patient population
    Mangold, Stefanie
    Wichmann, Julian L.
    Schoepf, U. Joseph
    Caruso, Damiano
    Tesche, Christian
    Steinberg, Daniel H.
    Varga-Szemes, Akos
    Stubenrauch, Andrew C.
    Bayer, Richard R., II
    Biancalana, Matthew
    Nikolaou, Konstantin
    De Cecco, Carlo N.
    [J]. EUROPEAN RADIOLOGY, 2017, 27 (06) : 2298 - 2308
  • [15] Impact of an advanced image-based monoenergetic reconstruction algorithm on coronary stent visualization using third generation dual-source dual-energy CT: a phantom study
    Mangold, Stefanie
    Cannao, Paola M.
    Schoepf, U. Joseph
    Wichmann, Julian L.
    Canstein, Christian
    Fuller, Stephen R.
    Muscogiuri, Giuseppe
    Varga-Szemes, Akos
    Nikolaou, Konstantin
    De Cecco, Carlo N.
    [J]. EUROPEAN RADIOLOGY, 2016, 26 (06) : 1871 - 1878
  • [16] Effect of automated tube voltage selection, integrated circuit detector and advanced iterative reconstruction on radiation dose and image quality of 3rd generation dual-source aortic CT angiography: An intra-individual comparison
    Mangold, Stefanie
    De Cecco, Carlo N.
    Wichmann, Julian L.
    Canstein, Christian
    Varga-Szemes, Akos
    Caruso, Damiano
    Fuller, Stephen R.
    Bamberg, Fabian
    Nikolaou, Konstantin
    Schoepf, U. Joseph
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2016, 85 (05) : 972 - 978
  • [17] Low-Tube-Voltage, High-Tube-Current Multidetector Abdominal CT: Improved Image Quality and Decreased Radiation Dose with Adaptive Statistical Iterative Reconstruction Algorithm-Initial Clinical Experience
    Marin, Daniele
    Nelson, Rendon C.
    Schindera, Sebastian T.
    Richard, Samuel
    Youngblood, Richard S.
    Yoshizumi, Terry T.
    Samei, Ehsan
    [J]. RADIOLOGY, 2010, 254 (01) : 145 - 153
  • [18] Closing in on the K Edge: Coronary CT Angiography at 100, 80, and 70 kV-Initial Comparison of a Second-versus a Third-Generation Dual-Source CT System
    Meyer, Mathias
    Haubenreisser, Holger
    Schoepf, U. Joseph
    Vliegenthart, Rozemarijn
    Leidecker, Christianne
    Allmendinger, Thomas
    Lehmann, Ralf
    Sudarski, Sonja
    Borggrefe, Martin
    Schoenberg, Stefan O.
    Henzler, Thomas
    [J]. RADIOLOGY, 2014, 273 (02) : 373 - 382
  • [19] Evaluation of individually body weight adapted contrast media injection in coronary CT-angiography
    Mihl, Casper
    Kok, Madeleine
    Altintas, Sibel
    Kietselaer, Bas L. J. H.
    Turek, Jakub
    Wildberger, Joachim E.
    Das, Marco
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2016, 85 (04) : 830 - 836
  • [20] Renker M, 2013, EXPERT REV CARDIOVAS, V11, P403, DOI [10.1586/erc.12.178, 10.1586/ERC.12.178]