Polymer-Based Chemicapacitor Sensor for 1-Octanol and Relative Humidity Detections at Different Temperatures and Frequencies

被引:6
|
作者
Emadi, Tahereh Arezoo [1 ]
Shafai, Cyrus [1 ]
Thomson, Douglas J. [1 ]
Freund, Michael S. [2 ]
White, Noel D. G. [3 ]
Jayas, Digvir S. [4 ]
机构
[1] Univ Manitoba, Dept Elect Engn, Winnipeg, MB R3T 6V6, Canada
[2] Univ Manitoba, Dept Chem, Winnipeg, MB R3N 2N2, Canada
[3] Agr & Agri Food Canada, Cereal Res Ctr, Winnipeg, MB R3T 2M9, Canada
[4] Univ Manitoba, Dept Biosyst Engn, Winnipeg, MB R3T 2N2, Canada
关键词
Chemicapacitor; heat transfer simulations; interdigitated electrodes; polymer-based sensor; sensitivity; temperature variation; GAS SENSOR; ELECTRONIC NOSE; DEPENDENCE; VOLATILES; GRAIN;
D O I
10.1109/JSEN.2012.2220760
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper, the temperature dependency of conventional polymer-based gas sensors is addressed and a novel polymer-based chemicapacitor sensor is presented for application in early detection of deterioration of grain in storage facilities. 3-D heat transfer simulations are used to investigate several heated platforms with the sensing area in millimeter range dimensions to enhance spoilage-induced analyte detection. A resistive heater is employed to heat and maintain the sensor at the desired operating temperature. The platform is optimized to achieve a uniform heat distribution throughout the sensing area with a temperature variation of Delta T <= 1 degrees C. Capacitive measurements are performed as a more sophisticated technique for analyte detection, where mechanisms other than swelling are involved. In this method, the need for conductive filler is eliminated, resulting in an improvement in sensor reproducibility and repeatability. 1-octanol and relative humidity measurements are performed, as they are the two key volatiles due to grain deterioration. The results verify functionality of the fabricated sensors at different temperatures, in ppm range for 1-octanol, and up to 75% RH. Responses at the elevated temperature of 40 degrees C, above the grain bins ambient temperature, are insensitive to ambient temperature fluctuations. Sensitivity measurements demonstrate that an array of detectors, each held at different temperatures and operating at different frequencies, can be utilized to further enhance the sensor sensitivity and selectivity to a desired analyte.
引用
收藏
页码:519 / 527
页数:9
相关论文
共 40 条
  • [31] FT-IR studies and excess thermodynamic properties of binary liquid mixtures 2-(2-butoxyethoxy) ethanol with 1-hexanol, 1-octanol and 1-decanol at different temperatures
    Kaur, Prabjot
    Dubey, Gyan Prakash
    JOURNAL OF CHEMICAL THERMODYNAMICS, 2018, 126 : 74 - 81
  • [32] Effect of hygroscopic polymer-coatings on the performance of relative humidity sensor based on macro-bend single-mode fiber
    Al-Hayali, Sarah Kadhim
    Salman, Ansam M.
    Al-Janabi, Abdul Hadi
    OPTICAL FIBER TECHNOLOGY, 2021, 62 (62)
  • [33] Conversion of relative humidity in SF6 gas-insulated equipment at different temperatures based on the Polanyi adsorption potential theory
    Lu Chao
    Hu Xiaoguang
    2006 IEEE INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE PROCEEDINGS, VOLS 1-5, 2006, : 638 - +
  • [34] Anode state observation of polymer electrolyte membrane fuel cell based on unscented Kalman filter and relative humidity sensor before flooding
    Xu, Liangfei
    Hu, Zunyan
    Fang, Chuan
    Li, Jianqiu
    Hong, Po
    Jiang, Hongliang
    Guo, Di
    Ouyang, Minggao
    RENEWABLE ENERGY, 2021, 168 : 1294 - 1307
  • [35] RELATIVE HUMIDITY QCM SENSOR BASED ON PEDOT-PSS [POLY(3,4-ETHYLENDIOXYTHIOPHENE)-POLY(STYRENESULFONATE)] POLYMER FILMS
    Neri, G.
    Micali, G.
    Rizzo, G.
    Bonavita, A.
    PROCEEDINGS OF THE 13TH ITALIAN CONFERENCE ON SENSORS AND MICROSYSTEMS, 2009, : 119 - +
  • [36] Polymer-based colorimetric and "turn off" fluorescence sensor incorporating benzo[2,1,3]thiadiazole moiety for Hg2+Detection
    Ma, Xiao
    Song, Fengyan
    Wang, Lu
    Cheng, Yixiang
    Zhu, Chengjian
    JOURNAL OF POLYMER SCIENCE PART A-POLYMER CHEMISTRY, 2012, 50 (03) : 517 - 522
  • [37] Polymer-based fluorescent sensor incorporating 2,2′-bipyridyl and benzo[2,1,3]thiadiazole moieties for Cu2+ detection
    Dong, Yu
    Koken, Biyhaliy
    Ma, Xiao
    Wang, Lu
    Cheng, Yixiang
    Zhu, Chengjian
    INORGANIC CHEMISTRY COMMUNICATIONS, 2011, 14 (11) : 1719 - 1722
  • [38] Poly(ethylene-co-tetrafluoroethylene) (ETFE)-based graft-type polymer electrolyte membranes with different ion exchange capacities: Relative humidity dependence for fuel cell applications
    Tap Tran Duy
    Sawada, Shin-ichi
    Hasegawa, Shin
    Katsumura, Yosuke
    Maekawa, Yasunari
    JOURNAL OF MEMBRANE SCIENCE, 2013, 447 : 19 - 25
  • [39] A promising ultra-sensitive CO2 sensor at varying concentrations and temperatures based on Fano resonance phenomenon in different 1D phononic crystal designs
    Abdulkarem H. M. Almawgani
    Hamza Makhlouf Fathy
    Hussein A. Elsayed
    Yahya Ali Abdelrahman Ali
    Ahmed Mehaney
    Scientific Reports, 13
  • [40] A promising ultra-sensitive CO2 sensor at varying concentrations and temperatures based on Fano resonance phenomenon in different 1D phononic crystal designs
    Almawgani, Abdulkarem H. M.
    Fathy, Hamza Makhlouf
    Elsayed, Hussein A.
    Ali, Yahya Ali Abdelrahman
    Mehaney, Ahmed
    SCIENTIFIC REPORTS, 2023, 13 (01)