Polymer-Based Chemicapacitor Sensor for 1-Octanol and Relative Humidity Detections at Different Temperatures and Frequencies

被引:6
|
作者
Emadi, Tahereh Arezoo [1 ]
Shafai, Cyrus [1 ]
Thomson, Douglas J. [1 ]
Freund, Michael S. [2 ]
White, Noel D. G. [3 ]
Jayas, Digvir S. [4 ]
机构
[1] Univ Manitoba, Dept Elect Engn, Winnipeg, MB R3T 6V6, Canada
[2] Univ Manitoba, Dept Chem, Winnipeg, MB R3N 2N2, Canada
[3] Agr & Agri Food Canada, Cereal Res Ctr, Winnipeg, MB R3T 2M9, Canada
[4] Univ Manitoba, Dept Biosyst Engn, Winnipeg, MB R3T 2N2, Canada
关键词
Chemicapacitor; heat transfer simulations; interdigitated electrodes; polymer-based sensor; sensitivity; temperature variation; GAS SENSOR; ELECTRONIC NOSE; DEPENDENCE; VOLATILES; GRAIN;
D O I
10.1109/JSEN.2012.2220760
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper, the temperature dependency of conventional polymer-based gas sensors is addressed and a novel polymer-based chemicapacitor sensor is presented for application in early detection of deterioration of grain in storage facilities. 3-D heat transfer simulations are used to investigate several heated platforms with the sensing area in millimeter range dimensions to enhance spoilage-induced analyte detection. A resistive heater is employed to heat and maintain the sensor at the desired operating temperature. The platform is optimized to achieve a uniform heat distribution throughout the sensing area with a temperature variation of Delta T <= 1 degrees C. Capacitive measurements are performed as a more sophisticated technique for analyte detection, where mechanisms other than swelling are involved. In this method, the need for conductive filler is eliminated, resulting in an improvement in sensor reproducibility and repeatability. 1-octanol and relative humidity measurements are performed, as they are the two key volatiles due to grain deterioration. The results verify functionality of the fabricated sensors at different temperatures, in ppm range for 1-octanol, and up to 75% RH. Responses at the elevated temperature of 40 degrees C, above the grain bins ambient temperature, are insensitive to ambient temperature fluctuations. Sensitivity measurements demonstrate that an array of detectors, each held at different temperatures and operating at different frequencies, can be utilized to further enhance the sensor sensitivity and selectivity to a desired analyte.
引用
收藏
页码:519 / 527
页数:9
相关论文
共 40 条
  • [1] Uncertainty analysis of polymer-based capacitive relative humidity sensor at negative temperatures and low humidity levels
    Kapic, Amar
    Tsirou, Andromachi
    Verdini, Piero Giorgio
    Carrara, Sandro
    MEASUREMENT, 2023, 209
  • [2] Polymer-based Micromachined Chemicapacitor Gas Sensor on a Temperature Controlled Platform
    Emadi, T. A.
    Shafai, C.
    Thomson, D. J.
    Freund, M. S.
    White, N. D. G.
    Jayas, D. S.
    2011 IEEE SENSORS, 2011, : 1024 - 1027
  • [3] Temperature and humidity dependence of a polymer-based gas sensor
    Buehler, MG
    Ryan, MA
    ELECTRO-OPTICAL TECHNOLOGY FOR REMOTE CHEMICAL DETECTION AND IDENTIFICATION II, 1997, 3082 : 40 - 48
  • [4] Flexible and Transparent Polymer-Based Optical Humidity Sensor
    Lazarova, Katerina
    Bozhilova, Silvia
    Ivanova, Sijka
    Christova, Darinka
    Babeva, Tsvetanka
    SENSORS, 2021, 21 (11)
  • [5] Radiation effect on the polymer-based capacitive relative humidity sensors
    Shchemerov, I., V
    Legotin, S. A.
    Lagov, P. B.
    Pavlov, Y. S.
    Tapero, K., I
    Petrov, A. S.
    Sidelev, A., V
    Stolbunov, V. S.
    Kulevoy, T., V
    Letovaltseva, M. E.
    Murashev, V. N.
    Konovalov, M. P.
    Kirilov, V. N.
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2022, 54 (08) : 2871 - 2876
  • [6] POLYMER-BASED CAPACITIVE HUMIDITY SENSOR - CHARACTERISTICS AND EXPERIMENTAL RESULTS
    DELAPIERRE, G
    GRANGE, H
    CHAMBAZ, B
    DESTANNES, L
    SENSORS AND ACTUATORS, 1983, 4 (01): : 97 - 104
  • [7] Polymer-based humidity sensor with fast response and multiple functions
    Li, Yalong
    Lan, Jian
    Hu, Jiahao
    Hu, Shouyuan
    Wang, Junbo
    Zhou, Feng
    Li, Pei
    Jiang, Jie
    Chen, Liang
    MATERIALS SCIENCE IN SEMICONDUCTOR PROCESSING, 2025, 190
  • [8] Nonlinear parameter (B/A) measurements in methanol, 1-butanol and 1-octanol for different pressures and temperatures
    Plantier, F
    Daridon, JL
    Lagourette, B
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2002, 35 (10) : 1063 - 1067
  • [9] Humidity Monitoring Using a Flexible Polymer-based Microwave Sensor and Machine Learning
    Ngoune, Bernard Bobby
    Hallil, Hamida
    George, Julien
    Dejous, Corinne
    Cloutet, Eric
    Bondu, Benoit
    Bila, Stephane
    Baillargeat, Dominique
    2022 IEEE SENSORS, 2022,
  • [10] Densities, Viscosities, and Refractive Indices of Dimethyl Carbonate+1-Hexanol/1-Octanol Binary Mixtures at Different Temperatures
    Moosavi, Mehrdad
    Motahari, Ahmad
    Vahid, Amir
    Akbar, Vahideh
    Rostami, Abbas Ali
    Omrani, Abdollah
    JOURNAL OF CHEMICAL AND ENGINEERING DATA, 2016, 61 (06): : 1981 - 1991