Intermittent gas-liquid two-phase flow in helically coiled tubes

被引:12
作者
Zhu, Guangyu [1 ]
Yang, Xingtuan [1 ]
Jiang, Shengyao [1 ]
Zhu, Hongye [1 ]
机构
[1] Tsinghua Univ, Key Lab Adv Reactor Engn & Safety, Collaborat Innovat Ctr Adv Nucl Energy Technol, Inst Nucl & New Energy Technol,Minist Educ, Beijing 100084, Peoples R China
基金
中国国家自然科学基金;
关键词
Intermittent flow; Helically coiled tube; Void fraction; Drift flux model; Slug frequency; VOID FRACTION CORRELATIONS; PRESSURE-DROP; SLUG FLOW; STATISTICAL PARAMETERS; PATTERNS;
D O I
10.1016/j.ijmultiphaseflow.2019.04.013
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
This paper experimentally investigated the air-water intermittent flow in four helically coiled tubes with inner diameter of 0.016m, coil diameters of 0.24, 0.43 and 0.80m, and inclination angles of 5 degrees and 15 degrees A double conductivity probe was used to measure the hydrodynamic parameters at 48 points in the outlet cross section. The results showed that centrifugal force and Dean Vortices were the major mechanisms that influenced the void fraction distribution, elongated bubble length, slug length and slug frequency. Because of centrifugal force, the void fraction profile rotated an angle which approached to 90 degrees as liquid superficial velocity increased and coil diameter decreased. Due to the Dean Vortices, the elongated bubble length and slug length decreased as the coil diameter decreased, leading to an increase of slug frequency. A dimensionless parameter Z representing the ratio of the centrifugal force to the gravity was presented, which provides a quantitative criterion to evaluate the influence of centrifugal force. In terms of Z, correlations predicting the deviation angle, elongated bubble length and slug frequency were built, which met the experimental data well when the coil diameter is between 0.24 and 0.80m and the inclination angle between 5 and 15. Moreover, a drift flux model for HCTs was presented. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页码:113 / 124
页数:12
相关论文
共 27 条
[21]   An experimental study of the statistical parameters of gas-liquid two-phase slug flow in horizontal pipeline [J].
Wang, Xin ;
Guo, Liejin ;
Zhang, Ximin .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2007, 50 (11-12) :2439-2443
[22]   Comparison of void fraction correlations for different flow patterns in horizontal and upward inclined pipes [J].
Woldesemayat, Melkamu A. ;
Ghajar, Afshin J. .
INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 2007, 33 (04) :347-370
[23]   Evaporation heat transfer and pressure drop of HFC-134a in a helically coiled concentric tube-in-tube heat exchanger [J].
Wongwises, S ;
Polsongkram, M .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2006, 49 (3-4) :658-670
[24]   Influence of Froude number on physical processes determining frequency of slugging in horizontal gas-liquid flows [J].
Woods, BD ;
Hanratty, TJ .
INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 1999, 25 (6-7) :1195-1223
[25]   An investigation and comparative study of the pressure drop in air-water two-phase flow in vertical helicoidal pipes [J].
Xin, RC ;
Awwad, A ;
Dong, ZF ;
Ebadian, MA ;
Soliman, HM .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1996, 39 (04) :735-743
[26]   Current status and technical description of Chinese 2 x 250 MWth HTR-PM demonstration plant [J].
Zhang, Zuoyi ;
Wu, Zongxin ;
Wang, Dazhong ;
Xu, Yuanhui ;
Sun, Yuliang ;
Li, Fu ;
Dong, Yujie .
NUCLEAR ENGINEERING AND DESIGN, 2009, 239 (07) :1212-1219
[27]   Flow regime identification for upward two-phase flow in helically coiled tubes [J].
Zhu, Hongye ;
Li, Zhaoxu ;
Yang, Xingtuan ;
Zhu, Guangyu ;
Tu, Jiyuan ;
Jiang, Shengyao .
CHEMICAL ENGINEERING JOURNAL, 2017, 308 :606-618