Thickness Profiles of Retinal Layers by Optical Coherence Tomography Image Segmentation

被引:142
作者
Bagci, Ahmet Murat [2 ]
Shahidi, Mahnaz [1 ]
Ansari, Rashid [2 ]
Blair, Michael [1 ]
Blair, Norman Paul [1 ]
Zelkha, Ruth [1 ]
机构
[1] Univ Illinois, Dept Ophthalmol & Visual Sci, Chicago, IL 60612 USA
[2] Univ Illinois, Dept Elect & Comp Engn, Chicago, IL 60612 USA
关键词
D O I
10.1016/j.ajo.2008.06.010
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To report an image segmentation algorithm that was developed to provide quantitative thickness measurement of six retinal layers in optical coherence tomography (OCT) images. DESIGN: Prospective cross-sectional study. METHODS: Imaging was performed with time- and spectral-domain OCT instruments in 15 and 10 normal healthy subjects, respectively. A dedicated software algorithm was developed for boundary detection based on a 2-dimensional edge detection scheme, enhancing edges along the retinal depth while suppressing speckle noise. Automated boundary detection and quantitative thickness measurements derived by the algorithm were compared with measurements obtained from boundaries manually marked by three observers. Thickness profiles for six retinal layers were generated in normal subjects. RESULTS: The algorithm identified seven boundaries and measured thickness of six retinal layers: nerve fiber layer, inner plexiform layer and ganglion cell layer, inner nuclear layer, outer plexiform, layer, outer nuclear layer and photoreceptor inner segments (ONL+PIS), and photoreceptor outer segments (POS). The root mean squared error between the manual and automatic boundary detection ranged between 4 and 9 [cm. The mean absolute values of differences between automated and manual thickness measurements were between 3 and 4 mu m, and comparable to interobserver differences. Inner retinal thickness profiles demonstrated minimum thickness at the fovea, corresponding to normal anatomy. The OPL and ONL+PIS thickness profiles respectively displayed a minimum and maximum thickness at the fovea. The POS thickness profile was relatively constant along the scan through the fovea. CONCLUSIONS: The application of this image segmentation technique is promising for investigating thickness changes of retinal layers attributable to disease progression and therapeutic intervention. (Am J Ophthalmol 2008;146:679-687. (C) 2008 by Elsevier Inc. All rights reserved.)
引用
收藏
页码:679 / 687
页数:9
相关论文
共 11 条
  • [1] BAGCI A, 2007, C P IEEE, P144
  • [2] BAGCI A, 2007, C P IEEE, P422
  • [3] Automatic recovery of the optic nervehead geometry in optical coherence tomography
    Boyer, KL
    Herzog, A
    Roberts, C
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2006, 25 (05) : 553 - 570
  • [5] Quantification of photoreceptor layer thickness in normal eyes using optical coherence tomography
    Chan, Annie
    Duker, Jay S.
    Ishikawa, Hiroshi
    Ko, Tony H.
    Schuman, Joel S.
    Fujimoto, James G.
    [J]. RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2006, 26 (06): : 655 - 660
  • [6] MAXIMUM LIKELIHOOD FROM INCOMPLETE DATA VIA EM ALGORITHM
    DEMPSTER, AP
    LAIRD, NM
    RUBIN, DB
    [J]. JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES B-METHODOLOGICAL, 1977, 39 (01): : 1 - 38
  • [7] Photoreceptor inner segments in monkey and human retina: Mitochondrial density, optics, and regional variation
    Hoang, QV
    Linsenmeier, RA
    Chung, CK
    Curcio, CA
    [J]. VISUAL NEUROSCIENCE, 2002, 19 (04) : 395 - 407
  • [8] Macular segmentation with optical coherence tomography
    Ishikawa, H
    Stein, DM
    Wollstein, G
    Beaton, S
    Fujimoto, JG
    Schuman, JS
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46 (06) : 2012 - 2017
  • [9] Retinal thickness measurements from optical coherence tomography using a Markov boundary model
    Koozekanani, D
    Boyer, K
    Roberts, C
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2001, 20 (09) : 900 - 916
  • [10] Retinal nerve fiber layer thickness map determined from optical coherence tomography images
    Mujat, M
    Chan, RC
    Cense, B
    Park, BH
    Joo, C
    Akkin, T
    Chen, TC
    de Boer, JF
    [J]. OPTICS EXPRESS, 2005, 13 (23): : 9480 - 9491