An Update on Three-Dimensional CT Angiography in Aneurysms: A Useful Modality for a Neurosurgeon

被引:7
|
作者
Kumar, Ashish [1 ]
Kato, Yoko [2 ]
Motoharu, Hayakawa [2 ]
Sifang, Chen [3 ]
Junpei, Oda [2 ]
Takeya, Watabe [2 ]
Shuei, Imizu [2 ]
Daikichi, Oguri [2 ]
Yuichi, Hirose [2 ]
机构
[1] Bombay Hosp Inst Med Sci, Dept Neurosurg, Bombay, Maharashtra, India
[2] Fujita Hlth Univ Hosp, Dept Neurosurg, Toyoake, Aichi, Japan
[3] Xiamen Univ, Dept Neurosurg, Affiliated Hosp 1, Xiamen, Peoples R China
关键词
Aneurysm; Subarachnoid hemorrhage; Computed tomography angiography; COMPUTED-TOMOGRAPHY ANGIOGRAPHY; SUBARACHNOID HEMORRHAGE;
D O I
10.5137/1019-5149.JTN.5958-12.0
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The role of three-dimensional computed tomography angiography (3D-CTA) in management of aneurysms has been fairly acknowledged in the past. There have been numerous articles in the literature regarding its potential threat to the conventional "gold standard", i.e. digital subtraction angiography (DSA). We study the technology used at a tertiary care hospital in Japan which performs,a large number of aneurysm surgeries a year and review the recent literature to gain an insight into the current role of 3D-CTA in detection of aneurysms and if it can be a front line modality of investigation from a neurosurgeon's point of view. At many centres including those in India, DSA is still treated as the first choice of investigation. Although 3D CTA has some limitations, it can provide an unmatched multi-directional view of the aneurysmal morphology and its surroundings including relations with the skull base and blood vessels. This may provide an invaluable help to a neurosurgeon who is usually concerned about many other associated factors involved in approaching an aneurysm.
引用
收藏
页码:304 / 311
页数:8
相关论文
共 50 条
  • [41] EXPERIENCE WITH THREE-DIMENSIONAL COMPUTED TOMOGRAPHIC ANGIOGRAPHY IN IBADAN, NIGERIA
    Ogbole, G. I.
    Ogunseyinde, A. O.
    Obajimi, M. O.
    Adeyinka, O.
    NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2010, 13 (02) : 187 - 194
  • [42] Reliability and accuracy assessment of morphometric measurements obtained with software for three-dimensional reconstruction of brain aneurysms relative to cerebral angiography measures
    Munarriz, Pablo M.
    Barcena, Eduardo
    Alen, Jose F.
    Castano-Leon, Ana M.
    Paredes, Igor
    Moreno-Gomez, Luis Miguel
    Garcia-Perez, Daniel
    Jimenez-Roldan, Luis
    Gomez, Pedro A.
    Lagares, Alfonso
    INTERVENTIONAL NEURORADIOLOGY, 2021, 27 (02) : 191 - 199
  • [43] Endovascular embolization of small ruptured intracranial aneurysms using a biplane angiographic system with three-dimensional rotational digital subtraction angiography
    Hai, Jian
    Deng, Dong-Feng
    Chen, Zuo-Quan
    Pan, Qing-Gang
    JOURNAL OF CLINICAL NEUROSCIENCE, 2009, 16 (08) : 1028 - 1033
  • [44] Three-dimensional computed tomography angiography and magnetic resonance angiography of carotid bifurcation stenosis
    Binaghi, S
    Maeder, P
    Uské, A
    Meuwly, JY
    Devuyst, G
    Meuli, RA
    EUROPEAN NEUROLOGY, 2001, 46 (01) : 25 - 34
  • [45] Maxillofacial trunk identified by three-dimensional computed tomography angiography
    Iwai, Toshinori
    Sugiyama, Satomi
    Koizumi, Toshiyuki
    Mitsudo, Kenji
    SURGICAL AND RADIOLOGIC ANATOMY, 2024, 47 (01)
  • [46] Celiac artery aneurysm: Diagnosis by color Doppler sonography and three-dimensional CT angiography
    Soudack, M
    Gaitini, D
    Ofer, A
    JOURNAL OF CLINICAL ULTRASOUND, 1999, 27 (01) : 49 - 51
  • [47] RAPID aneurysm accurately measures aneurysm size on CT angiography compared to three-dimensional digital subtraction angiography
    Snyder, Sarah J.
    Gauden, Andrew
    Copeland, Karen
    Spiotta, Alejandro M.
    Heit, Jeremy J.
    INTERVENTIONAL NEURORADIOLOGY, 2023,
  • [48] Intracranial aneurysms:: Detection with gadolinium-enhanced dynamic three-dimensional MR angiography -: Initial results
    Metens, T
    Rio, F
    Balériaux, D
    Roger, T
    David, P
    Rodesch, G
    RADIOLOGY, 2000, 216 (01) : 39 - 46
  • [49] Contrast-enhanced three-dimensional MR angiography with an elliptical centric view for the evaluation of intracranial aneurysms
    Isoda, Haruo
    Inagawa, Shoichi
    Ito, Tatsuhiko
    Takeda, Hiroyasu
    Takehara, Yasuo
    Nozaki, Atsushi
    Sakahara, Harumi
    EUROPEAN RADIOLOGY, 2007, 17 (05) : 1221 - 1225
  • [50] Three-dimensional renal CT angiography for guiding segmental renal artery clamping during laparoscopic partial nephrectomy
    Xu, Yi
    Shao, Pengfei
    Zhu, Xiaomei
    Lv, Qiang
    Liu, Wangyan
    Xu, Hai
    Zhu, Yinsu
    Yang, Guangyu
    Tang, Lijun
    Yin, Changjun
    CLINICAL RADIOLOGY, 2013, 68 (11) : E609 - E616