A numerical study of pulsatile blood flow in an eccentric catheterized artery using a fast algorithm

被引:24
作者
Daripa, P [1 ]
Dash, RK [1 ]
机构
[1] Texas A&M Univ, Dept Math, College Stn, TX 77843 USA
关键词
Poisson solver; fast algorithm; pulsatile blood flow; eccentric catheterized artery;
D O I
10.1023/A:1014332225766
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The pulsatile blood flow in an eccentric catheterized artery is studied numerically by making use of an extended version of the fast algorithm of Borges and Daripa [J. Comp. Phys., 2001]. The mathematical model involves the usual assumptions that the arterial segment is straight, the arterial wall is rigid and impermeable, blood is an incompressible Newtonian fluid, and the flow is fully developed. The flow rate (flux) is considered as a periodic function of time (prescribed). The axial pressure gradient and velocity distribution in the eccentric catheterized artery are obtained as solutions of the problem. Through the computed results on axial pressure gradient, the increases in mean pressure gradient and frictional resistance in the artery due to catheterization are estimated. These estimates can be used to correct the error involved in the measured pressure gradients using catheters.
引用
收藏
页码:1 / 22
页数:22
相关论文
共 25 条
[1]   MEASUREMENT OF TRANSSTENOTIC PRESSURE-GRADIENT DURING PERCUTANEOUS TRANS-LUMINAL CORONARY ANGIOPLASTY [J].
ANDERSON, HV ;
ROUBIN, GS ;
LEIMGRUBER, PP ;
COX, WR ;
DOUGLAS, JS ;
KING, SB ;
GRUENTZIG, AR .
CIRCULATION, 1986, 73 (06) :1223-1230
[2]   ESTIMATED MEAN FLOW RESISTANCE INCREASE DURING CORONARY-ARTERY CATHETERIZATION [J].
BACK, LH .
JOURNAL OF BIOMECHANICS, 1994, 27 (02) :169-175
[3]   Flow rate pressure drop relation in coronary angioplasty: Catheter obstruction effect [J].
Back, LH ;
Kwack, EY ;
Back, MR .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1996, 118 (01) :83-89
[4]   Hemodynamic consequences of stenosis remodeling during coronary angioplasty [J].
Back, MR ;
White, RA ;
Kwack, EY ;
Back, LH .
ANGIOLOGY, 1997, 48 (02) :99-109
[5]   HYDRO- AND HEMODYNAMIC EFFECTS OF CATHETERIZATION OF VESSELS .1. EXPERIMENTAL-MODEL [J].
BJORNO, L ;
PETTERSSON, H .
ACTA RADIOLOGICA-DIAGNOSIS, 1976, 17 (04) :511-518
[6]   HYDRODYNAMIC AND HEMODYNAMIC EFFECTS OF CATHETERIZATION OF VESSELS .5. EXPERIMENTAL AND CLINICAL CATHETERIZATION OF STENOSES [J].
BJORNO, L ;
PETTERSSON, H .
ACTA RADIOLOGICA-DIAGNOSIS, 1977, 18 (02) :193-209
[7]   HYDRODYNAMIC AND HEMODYNAMIC EFFECTS OF CATHETERIZATION OF VESSELS .2. MODEL EXPERIMENTS COMPARING CIRCULAR AND ANNULAR LUMEN AREA REDUCTION [J].
BJORNO, L ;
PETTERSSON, H .
ACTA RADIOLOGICA-DIAGNOSIS, 1976, 17 (06) :749-762
[8]  
BJORNO L, 1977, ACTA RADIOL DIAGN, V18, P1
[9]   A fast parallel algorithm for the Poisson equation on a disk [J].
Borges, L ;
Daripa, P .
JOURNAL OF COMPUTATIONAL PHYSICS, 2001, 169 (01) :151-192
[10]   Singular integral transforms and fast numerical algorithms [J].
Daripa, P ;
Mashat, D .
NUMERICAL ALGORITHMS, 1998, 18 (02) :133-157