A method for calibrating the CT-based attenuation correction of PET in human tissue

被引:20
作者
Watson, CC [1 ]
Rappoport, V
Faul, D
Townsend, DW
Carney, JP
机构
[1] Siemens Mol Imaging, Knoxville, TN 37932 USA
[2] Univ Tennessee, Med Ctr, Knoxville, TN 37920 USA
[3] Univ Pittsburgh, Med Ctr, Pittsburgh, PA 15213 USA
关键词
attenuation correction; human tissue; linear attenuation coefficient; PET; PET/CT;
D O I
10.1109/TNS.2005.862972
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The use of x-ray computed tomography (CT)-based attenuation correction for positron emission tomography (PET) in PET/CT systems requires the transformation of CT Hounsfield units (HU) to linear attenuation coefficients at 511 keV (LAC(511)). This cannot be done perfectly from a single peak kilovolt (kVp) CT scan due to variability in Compton and photoelectric composition and, thus, an approximate transformation must be employed. One difficulty in this lies in accurately determining the linear attenuation coefficients (LAC) in actual human tissue. Typically, phantoms consisting of synthetic materials thought to be approximate human tissue equivalents are employed instead. A potentially more accurate approach would be to use dual kVp CT scans to estimate LAC511 in actual human tissue and then base the single kVp transformation on these data. This approach would also permit an assessment of the dispersion of actual tissue values about the two-component trend lines typically used for the single kVp transformation. In this paper, we develop and assess this methodology.
引用
收藏
页码:102 / 107
页数:6
相关论文
共 16 条
  • [1] ENERGY-SELECTIVE RECONSTRUCTIONS IN X-RAY COMPUTERIZED TOMOGRAPHY
    ALVAREZ, RE
    MACOVSKI, A
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1976, 21 (05) : 733 - 744
  • [2] Antoch G, 2002, J NUCL MED, V43, P1339
  • [3] PET attenuation coefficients from CT images: experimental evaluation of the transformation of CT into PET 511-keV attenuation coefficients
    Burger, C
    Goerres, G
    Schoenes, S
    Buck, A
    Lonn, AHR
    von Schulthess, GK
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2002, 29 (07) : 922 - 927
  • [4] CARNEY JPJ, 2002, P IEEE NUC SCI S C M, V10
  • [5] Cohade C, 2003, J NUCL MED, V44, P412
  • [6] Artifacts at PET and PET/CT caused by metallic hip prosthetic material
    Goerres, GW
    Ziegler, SI
    Burger, C
    von Schulthess, TBGK
    Buck, A
    [J]. RADIOLOGY, 2003, 226 (02) : 577 - 584
  • [7] HAMILL JJ, 2004, P IEEE NUCL SCI S M, V9
  • [8] Impact of metallic dental implants on CT-based attenuation correction in a combined PET/CT scanner
    Kamel, EM
    Burger, C
    Buck, A
    von Schulthess, GK
    Goerres, GW
    [J]. EUROPEAN RADIOLOGY, 2003, 13 (04) : 724 - 728
  • [9] Attenuation correction for a combined 3D PET/CT scanner
    Kinahan, PE
    Townsend, DW
    Beyer, T
    Sashin, D
    [J]. MEDICAL PHYSICS, 1998, 25 (10) : 2046 - 2053
  • [10] KINAHAN PE, 2004, P IEEE NUCL SCI S M, V9