Heart Rate Variability and Extubation Readiness in Extremely Preterm Infants

被引:39
|
作者
Kaczmarek, Jennifer [1 ]
Chawla, Sanjay [3 ]
Marchica, Cinzia [2 ]
Dwaihy, Meghan [2 ]
Grundy, Linda [2 ]
Sant'Anna, Guilherme Mendes [1 ]
机构
[1] McGill Univ, Dept Pediat, Div Neonatol, Montreal, PQ H3A 2T5, Canada
[2] Univ Montreal, Sch Med, Montreal, PQ H3C 3J7, Canada
[3] Wayne State Univ, Dept Pediat, Div Neonatol, Detroit, MI 48202 USA
关键词
Heart rate variability; Extubation readiness; Extubation failure; Clinical predictors; BIRTH-WEIGHT INFANTS; SPECTRAL-ANALYSIS; VENTILATION; MORTALITY; SLEEP; CPAP;
D O I
10.1159/000347101
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Background: Mechanical ventilation (MV) is associated with changes in autonomic nervous system activity in preterm infants, which can be assessed by measurements of heart rate variability (HRV). Decreased HRV has been described in adults undergoing disconnection from MV; such information is not available in preterm infants. Objective: To compare differences in HRV between infants successfully extubated and those who failed, and to evaluate the accuracy of HRV as a predictor of extubation readiness. Methods: This is a prospective, observational study of infants with a birth weight <= 1,250 g undergoing their first extubation attempt. Heart rate was measured during a 60-min period immediately prior to extubation and HRV was calculated using the frequency domain analysis. Results: A total of 47 infants were studied; 36 were successfully extubated and 11 reintubated. There were no differences in patient demographics, ventilator settings, blood gases or postextubation management between the groups. All components of the HRV analysis were significantly decreased in infants who failed, generating high areas under the receiver operating characteristic curve. The specificity and positive predictive values were 100, but with limited sensitivity and negative predictive values. Conclusions: Infants considered 'ready to be extubated' but who subsequently failed their first extubation attempt had decreased HRV prior to extubation. Though promising, the value of HRV as a predictor of extubation readiness requires further evaluation. Copyright (c) 2013 S. Karger AG, Basel
引用
收藏
页码:42 / 48
页数:7
相关论文
共 50 条
  • [1] A predictive model for extubation readiness in extremely preterm infants
    Gupta, Dhruv
    Greenberg, Rachel G.
    Sharma, Amit
    Natarajan, Girija
    Cotten, Michael
    Thomas, Ronald
    Chawla, Sanjay
    JOURNAL OF PERINATOLOGY, 2019, 39 (12) : 1663 - 1669
  • [2] Prediction of Extubation readiness in extremely preterm infants by the automated analysis of cardiorespiratory behavior: study protocol
    Shalish, Wissam
    Kanbar, Lara J.
    Rao, Smita
    Robles-Rubio, Carlos A.
    Kovacs, Lajos
    Chawla, Sanjay
    Keszler, Martin
    Precup, Doina
    Brown, Karen
    Kearney, Robert E.
    Sant'Anna, Guilherme M.
    BMC PEDIATRICS, 2017, 17
  • [3] Automated Analysis of Respiratory Behavior in Extremely Preterm Infants and Extubation Readiness
    Robles-Rubio, C. A.
    Kaczmarek, J.
    Chawla, S.
    Kovacs, L.
    Brown, K. A.
    Kearney, R. E.
    Anna, G. M. Sant
    PEDIATRIC PULMONOLOGY, 2015, 50 (05) : 479 - 486
  • [4] Prediction of Extubation readiness in extremely preterm infants by the automated analysis of cardiorespiratory behavior: study protocol
    Wissam Shalish
    Lara J. Kanbar
    Smita Rao
    Carlos A. Robles-Rubio
    Lajos Kovacs
    Sanjay Chawla
    Martin Keszler
    Doina Precup
    Karen Brown
    Robert E. Kearney
    Guilherme M. Sant’Anna
    BMC Pediatrics, 17
  • [5] Heart Rate Variability in Extremely Preterm Infants Receiving Nasal CPAP and Non-Synchronized Noninvasive Ventilation Immediately After Extubation
    Latremouille, Samantha
    Al-Jabri, Ali
    Lamer, Philippe
    Kanbar, Lara
    Shalish, Wissam
    Kearney, Robert E.
    Sant'Anna, Guilherme M.
    RESPIRATORY CARE, 2018, 63 (01) : 62 - 69
  • [6] Does heart rate variability improve prediction of failed extubation in preterm infants?
    Fonseca Silva, Marciali Goncalves
    Gregorio, Michele Lima
    de Godoy, Moacir Fernandes
    JOURNAL OF PERINATAL MEDICINE, 2019, 47 (02) : 252 - 257
  • [7] The effect of massage on heart rate variability in preterm infants
    Smith, S. L.
    Lux, R.
    Haley, S.
    Slater, H.
    Beechy, J.
    Moyer-Mileur, L. J.
    JOURNAL OF PERINATOLOGY, 2013, 33 (01) : 59 - 64
  • [8] Markers of Successful Extubation in Extremely Preterm Infants, and Morbidity After Failed Extubation
    Chawla, Sanjay
    Natarajan, Girija
    Shankaran, Seetha
    Carper, Benjamin
    Brion, Luc P.
    Keszler, Martin
    Carlo, Waldemar A.
    Ambalavanan, Namasivayam
    Gantz, Marie G.
    Das, Abhik
    Finer, Neil
    Goldberg, Ronald N.
    Cotten, C. Michael
    Higgins, Rosemary D.
    JOURNAL OF PEDIATRICS, 2017, 189 : 113 - +
  • [9] The effects of nasal continuous positive airway pressure and high flow nasal cannula on heart rate variability in extremely preterm infants after extubation: A randomized crossover trial
    Latremouille, Samantha
    Shalish, Wissam
    Kanbar, Lara
    Lamer, Philippe
    Rao, Smita
    Kearney, Robert E.
    Sant'Anna, Guilherme M.
    PEDIATRIC PULMONOLOGY, 2019, 54 (06) : 788 - 796
  • [10] Prediction of Extubation Readiness in Extreme Preterm Infants Based on Measures of Cardiorespiratory Variability
    Precup, Doina
    Robles-Rubio, Carlos A.
    Brown, Karen A.
    Kanbar, L.
    Kaczmarek, J.
    Chawla, S.
    Sant'Anna, G. M.
    Kearney, Robert E.
    2012 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2012, : 5630 - 5633