Preoperative 123I/99mTc-Sestamibi Subtraction SPECT and SPECT/CT in Primary Hyperparathyroidism

被引:88
|
作者
Neumann, Donald R. [1 ]
Obuchowski, Nancy A. [2 ]
DiFilippo, Frank P. [1 ]
机构
[1] Cleveland Clin, Imaging Inst, Dept Nucl Med, Cleveland, OH 44195 USA
[2] Cleveland Clin, Imaging Inst, Dept Diagnost Radiol, Cleveland, OH 44195 USA
关键词
hyperparathyroidism; SPECT; SPECT/CT; hybrid imaging;
D O I
10.2967/jnumed.108.054858
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The trend toward focused surgical parathyroidectomy requires precise preoperative localization of parathyroid lesions in patients with hyperparathyroidism. The purpose of this study was to directly compare the diagnostic accuracy of (99m)Tc-sestamibi/(123)I subtraction SPECT with SPECT/CT for the localization of abnormal parathyroid glands in patients with primary hyperparathyroidism. Methods: A total of 61 consecutive surgical patients with primary hyperparathyroidism underwent both (123)I/99mTc-sestamibi subtraction SPECT and SPECT/CT scans preoperatively, using a hybrid SPECT/CT instrument that combined a dual-detector SPECT camera with a 6-slice multicletector spiral CT scanner. Four hours after being given (123)I-sodium iodide orally, each patient received (99m)Tc-sestamibi intravenously, followed immediately by a simultaneous, dual-isotope SPECT scan of the neck and upper chest. Then, without moving the patient, we performed a noncontrast-enhanced CT scan of the same body region. Normalization and subtraction of the (123)I SPECT images from the (99m)Tc SPECT images were performed. The subtraction SPECT and the coregistered fused SPECT/CT studies were interpreted separately, with images scored on a 5-point scale. Surgical and histopathologic findings were used as the standard of comparison. Results: Surgery was successful in 57 patients (solitary parathyroid adenoma in 48 patients, double parathyroid adenomas in 6 patients, and 10 hyperplastic parathyroid glands in 3 patients). The sensitivities of SPECT (50/70 = 71%) and SPECT/CT (49/70 = 70%) were similar (P = 0.779). The specificity of SPECT/CT (26/27 = 96%) was significantly greater than that of SPECT (13/27 = 48%; P = 0.006). The receiver-operating-characteristic area under the curve of SPECT/CT (0.833) was significantly greater than that of SPECT (0.632; P < 0.001). Conclusion: SPECT/CT is significantly more specific than dual-isotope subtraction SPECT for the preoperative identification of parathyroid lesions in patients with primary hyperparathyroidism.
引用
收藏
页码:2012 / 2017
页数:6
相关论文
共 50 条
  • [1] Comparison of 99mTc-sestamibi/123I subtraction SPECT/CT and combined planar pinhole image with 99mTc-sestamibi/123I subtraction SPECT/CT in hyperparathyroidism
    Seppanen, Marko
    Tunninen, Virpi
    Varjo, Pekka
    JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (03)
  • [2] Assessment of preoperative 123I/99mTc-SEstamibi subtraction planar scintigraphy, SPECT/CT and US in hyperparathyroidism
    Poullias, X.
    Guernou, M.
    Hapdey, S.
    Hitzel, A.
    Salles, A.
    Vera, P.
    Edet-Sanson, A.
    MEDECINE NUCLEAIRE-IMAGERIE FONCTIONNELLE ET METABOLIQUE, 2011, 35 (03): : 96 - 104
  • [3] Comparison of 99mTc-sestamibi/123I subtraction SPECT/CT and combined 99mTc-sestamibi/123I sub-traction SPECT/CT with planar pinhole image in hyperparathyroidism
    Tunninen, V.
    Varjo, P.
    Seppanen, M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 : S65 - S66
  • [4] Optimization of 99mTc-sestamibi/123I subtraction SPECT/CT protocol for parathyroid scintigraphy
    Tunninen, V.
    Kauppinen, T.
    Eskola, H.
    EMBEC & NBC 2017, 2018, 65 : 847 - 851
  • [5] Optimization of 99mTc-sestamibi/123I subtraction SPECT/CT protocol for parathyroid scintigraphy
    Tunninen, V.
    Kauppinen, T.
    Eskola, H.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2017, 44 : S826 - S827
  • [6] Value of 123I/99mTc-sestamibi parathyroid scintigraphy with subtraction SPECT/CT in primary hyperparathyroidism for directing minimally invasive parathyroidectomy
    Asseeva, Pauline
    Paladino, Nunzia Cinzia
    Guerin, Carole
    Castinetti, Frederic
    Vaillant-Lombard, Josiane
    Abdullah, Ahmad Esmaeel
    Farman-Ara, Bardia
    Loundou, Anderson
    Sebag, Frederic
    Taieb, David
    AMERICAN JOURNAL OF SURGERY, 2019, 217 (01): : 108 - 113
  • [7] 99mTc-sestamibi/123I subtraction SPECT-CT for parathyroid scintigraphy: 180° or 360°of SPECT acquisition?
    Tunninen, V.
    Varjo, P.
    Holm, A.
    Kauppinen, T.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2013, 40 : S173 - S173
  • [8] The Diagnostic Effectiveness of 99mTc-Sestamibi SPECT/CT in Primary Hyperparathyroidism
    Huang, J.
    Cheng, M.
    Tzen, K.
    Yen, R.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2012, 39 : S480 - S481
  • [9] Planar Scintigraphy with 123I/99mTc-Sestamibi, 99mTc-Sestamibi SPECT/CT, 11C-Methionine PET/CT, or Selective Venous Sampling Before Reoperation of Primary Hyperparathyroidism?
    Schalin-Jantti, Camilla
    Ryhanen, Eeva
    Heiskanen, Ilkka
    Seppanen, Marko
    Arola, Johanna
    Schildt, Jukka
    Vaisanen, Mika
    Nelimarkka, Lassi
    Lisinen, Irina
    Aalto, Ville
    Nuutila, Pirjo
    Valimaki, Matti J.
    JOURNAL OF NUCLEAR MEDICINE, 2013, 54 (05) : 739 - 747
  • [10] Does the digital CZT detector improve the results of 99mTc-sestamibi/123I subtraction SPECT/CT in parathyroid scintigraphy?
    Tunninen, V.
    Seppanen, M.
    Noponen, T.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2019, 46 (SUPPL 1) : S486 - S486