Soft tissue structures resisting anterior instability in a computational glenohumeral joint model

被引:5
作者
Elmore, Kevin A.
Wayne, Jennifer S. [1 ]
机构
[1] Virginia Commonwealth Univ, Orthopaed Res Lab, Dept Biomed Engn, Richmond, VA 23284 USA
关键词
musculoskeletal; computational model; shoulder; subluxation; dislocation; validation; FINITE-ELEMENT ANALYSIS; BIOMECHANICAL MODEL; SHOULDER JOINT; ROTATOR CUFF; MUSCULOSKELETAL MODEL; STABILIZING FUNCTION; ANATOMY; LIGAMENT; CADAVER; CAPSULE;
D O I
10.1080/10255842.2011.641120
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The glenohumeral joint is the most dislocated joint in the body due to the lack of bony constraints and the dependence on soft tissue for stability. The roles that various structures provide to joint function are important for understanding injury treatment and orthopaedic device design purposes. The goal of this study was to develop a computational model of the glenohumeral joint whereby joint behaviour was dictated by articular contact, ligamentous constraints, muscle loading and external perturbations. The bone structure of the computational model consisted of assembled computer tomographic images of the scapula, humerus and clavicle. The soft tissue elements were composed of forces and tension-only springs that represented muscles and ligaments. Validation of this model was achieved by comparing computational predictions to the results of a cadaveric experiment in which the relative contribution of muscles and ligaments to anterior joint stability was examined. The computational model predicted an anterior subluxation force that was similar to the cadaveric experimental results in humeral external rotation. The individual structure results showed the subscapularis to be critical to stabilisation in both neutral and external rotations, the biceps stabilised the joint in neutral but not in external rotation, and the inferior glenohumeral ligament resisted anterior displacement only in external rotation. The model's predictions were similar to the conclusions of the cadaveric experiment and the literature. Knowledge gained from this type of model could assist in further understanding the contribution of soft tissue stabilisers to joint function, pre-operative planning or the design of orthopaedic implants.
引用
收藏
页码:781 / 789
页数:9
相关论文
共 57 条
[1]  
Abboud JA, 2002, CLIN ORTHOP RELAT R, P48
[2]   A dynamic analysis of glenohumeral motion after simulated capsulolabral injury - A Cadaver model [J].
Apreleva, M ;
Hasselman, CT ;
Debski, RE ;
Fu, FH ;
Woo, SLY ;
Warner, JJPO .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1998, 80A (04) :474-480
[3]   Structural and mechanical properties of the glenohumeral joint posterior capsule [J].
Bey, MJ ;
Hunter, SA ;
Kilambi, N ;
Butler, DL ;
Lindenfeld, TN .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2005, 14 (02) :201-206
[4]  
Bhargav Divya, 2004, Aust Fam Physician, V33, P143
[5]  
Bigliani LU, 1996, CLIN ORTHOP RELAT R, P13
[6]   TENSILE PROPERTIES OF THE INFERIOR GLENOHUMERAL LIGAMENT [J].
BIGLIANI, LU ;
POLLOCK, RG ;
SOSLOWSKY, LJ ;
FLATOW, EL ;
PAWLUK, RJ ;
MOW, VC .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1992, 10 (02) :187-197
[7]  
Blasier R B, 1992, J Shoulder Elbow Surg, V1, P140, DOI 10.1016/1058-2746(92)90091-G
[8]   Posterior glenohumeral subluxation: Active and passive stabilization in a biomechanical model [J].
Blasier, RB ;
Soslowsky, LJ ;
Malicky, DM ;
Palmer, ML .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1997, 79A (03) :433-440
[9]  
Boardman N D, 1996, J Shoulder Elbow Surg, V5, P249, DOI 10.1016/S1058-2746(96)80050-4
[10]   A finite element model of the shoulder:: application to the comparison of normal and osteoarthritic joints [J].
Büchler, P ;
Ramaniraka, NA ;
Rakotomanana, LR ;
Iannotti, JP ;
Farron, A .
CLINICAL BIOMECHANICS, 2002, 17 (9-10) :630-639