Comparison of the bioMerieux NucliSENS EasyQ HIV-1 v2.0-HIV-1 RNA quantification assay versus Abbott RealTime HIV-1 and Roche Cobas TaqMan HIV-1 v2.0 on current epidemic HIV-1 variants

被引:18
|
作者
Mourez, Thomas [1 ,2 ,3 ]
Delaugerre, Constance [4 ,5 ]
Vray, Muriel [6 ]
Lemee, Veronique [3 ]
Simon, Francois [4 ,5 ]
Plantier, Jean-Christophe [1 ,2 ,3 ]
机构
[1] Normandie Univ, Caen, France
[2] Univ Rouen, IRIB, Equipe Accueil 2656, F-76183 Rouen, France
[3] CHU Rouen, Lab Virol, Associe Ctr Natl Reference VIH, F-76031 Rouen, France
[4] Univ Paris 07, F-75010 Paris, France
[5] Hop St Louis, AP HP, Lab Virol, F-75010 Paris, France
[6] Inst Pasteur, Unite Epidemiol Malad Emergentes, F-75014 Paris, France
关键词
HIV-1; Quantification; Genetic diversity; HIV-O; Viral load; IMMUNODEFICIENCY-VIRUS TYPE-1; GROUP-O; AMPLICOR; DISCREPANCIES; DIVERSITY; SUBTYPES; VERSION; IMPACT;
D O I
10.1016/j.jcv.2015.08.007
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Background: An improved version of the bioMerieux NucliSENS (R) EasyQ (R) HIV-1 v2.0 has been introduced to overcome the underquantification observed with previous versions, especially with non-B HIV-1 subtypes. Objectives: Comparing bioMerieux NucliSENS (R) EasyQ (R) HIV-1 v2.0 versus Roche Cobas CA/CTM v2.0 and Abbott RealTime HIV-1 assays for HIV-1 group M and non-M (N, O, P) viral load measurement. Study design: The three assays were tested in parallel on 103HIV-1 group M plasma samples, and on non-group M HIV-1 culture supernatants. Results: Values obtained for the 103HIV-1 group M plasma samples tested with bioMerieux assay showed good overall correlation compared to the 2 others. The Roche Cobas assay gave higher values than the bioMerieux assay, while Abbott and bioMerieux both displayed similar results. However, analysis showed a wider dispersion in results when comparing the bioMerieux NucliSENS (R) EasyQ (R) HIV-1 v2.0 and the other 2 techniques. All data taken into account, we observed frequent discrepancies in quantification, of the plasma samples and major differences above 1 log in 10/72 (13.8%). The quantification of non-M HIV groups in culture supernatant has shown variable results, with better quantification of HIV-O and of HIV-N respectively with the Abbott assay and the bioMerieux assay. Conclusions: The bioMerieux NucliSENS (R) EasyQ (R) HIV-1 v2.0 showed improved sensitivity to non-B HIV-M subtypes compared to previous versions. Notwithstanding, we observed frequent discrepancies and a wide dispersion in results when comparing bioMerieux NucliSENS (R) EasyQ (R) HIV-1 v2.0 and the other 2 techniques. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:76 / 81
页数:6
相关论文
共 50 条
  • [41] Performance of three commercial viral load assays, Versant human immunodeficiency virus type 1 (HIV-1) RNA bDNA v3.0, Cobas AmpliPrep/Cobas TaqMan HIV-1, and NucliSens HIV-1 EasyQ v1.2, testing HIV-1 non-B subtypes and recombinant variants
    Holguin, Africa
    Lopez, Marisa
    Molinero, Mar
    Soriano, Vincent
    JOURNAL OF CLINICAL MICROBIOLOGY, 2008, 46 (09) : 2918 - 2923
  • [42] Results of the Abbott RealTime HIV-1 Assay for Specimens Yielding "Target Not Detected" Results by the Cobas AmpliPrep/Cobas TaqMan HIV-1 Test
    Babady, N. Esther
    Germer, Jeffrey J.
    Yao, Joseph D. C.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2010, 48 (03) : 969 - 971
  • [43] RNA versus DNA (NucliSENS EasyQ HIV-1 v1.2 versus Amplicor HIV-1 DNA Test v1.5) for Early Diagnosis of HIV-1 Infection in Infants in Senegal
    Kebe, K.
    Ndiaye, O.
    Ndiaye, H. Diop
    Mengue, P. Mbakob
    Guindo, P. M. M.
    Diallo, S.
    Leye, N.
    Gueye, S. B.
    Diallo, A. Gaye
    Kane, C. Toure
    Mboup, S.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2011, 49 (07) : 2590 - 2593
  • [44] Method Comparison Between the VERSANT® HIV-1 RNA 1.0 Assay (kPCR) and the Abbott RealTime™ HIV-1 Assay
    Gonin, G. M.
    Yao, J. D.
    Wagner, C.
    Lin, C.
    Swiatkowski, P.
    Tam, S. M.
    Canchola, J.
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2008, 10 (06): : 587 - 587
  • [45] Comparison of the Roche COBAS® AmpliPrep/COBAS® TaqMan® HIV-1 and the Seimens Versant bDNA HIV-1 Version 3.0
    Dokus, B. J.
    Marchetti, A. L.
    Bentley, H. A.
    Bartels, C. L.
    Tsongalis, G. J.
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2009, 11 (06): : 639 - 639
  • [46] Evaluation of NucliSens EasyQ™ HIV-1 assay for quantification of HIV-1 subtypes prevalent in south-east Asia
    Lam, H. Y.
    Chen, J. H. K.
    Wong, K. H.
    Chan, K.
    Li, P.
    Lee, M. P.
    Tsang, D. N.
    Yuen, K. Y.
    Yam, W. C.
    JOURNAL OF CLINICAL VIROLOGY, 2007, 38 (01) : 39 - 43
  • [47] Comparative evaluation of the Abbott HIV-1 RealTime™ assay with the Standard Roche COBAS® Amplicor™ HIV-1 Monitor® Test, v1.5 for determining HIV-1 RNA levels in plasma specimens from Pune, India
    Khopkar, Priyanka
    Mallav, Vikas
    Chidrawar, Shweta
    Kulkarni, Smita
    JOURNAL OF VIROLOGICAL METHODS, 2013, 191 (01) : 82 - 87
  • [48] Comparison of the Abbott RealTime Human Immunodeficiency Virus Type 1 (HIV-1) Assay to the Cobas AmpliPrep/Cobas TaqMan HIV-1 Test: Workflow, Reliability, and Direct Costs
    Sloma, Cari R.
    Germer, Jeffrey J.
    Gerads, Tara M.
    Mandrekar, Jayawant N.
    Mitchell, P. Shawn
    Yao, Joseph D. C.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2009, 47 (04) : 889 - 895
  • [49] Performance of the Abbott Realtime HIV-1: An automated assay for quantification of HIV-1 viral load in plasma.
    Abravaya, K
    Tang, N
    Huang, S
    Cloherty, G
    Mak, W
    Salituro, J
    Robinson, J
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2005, 7 (05): : 670 - 670
  • [50] Performance evaluation of the Bioneer AccuPower® HIV-1 Quantitative RT-PCR kit: Comparison with the Roche COBAS® AmpliPrep/COBAS TaqMan® HIV-1 Test Ver.2.0 for quantification of HIV-1 viral load in Indonesia
    Kosasih, Agus Susanto
    Sugiarto, Christine
    Hayuanta, Hubertus Hosti
    Juhaendi, Runingsih
    Setiawan, Lyana
    ASIAN PACIFIC JOURNAL OF ALLERGY AND IMMUNOLOGY, 2018, 36 (02): : 120 - 125