Comparison of the bioMerieux NucliSENS EasyQ HIV-1 v2.0-HIV-1 RNA quantification assay versus Abbott RealTime HIV-1 and Roche Cobas TaqMan HIV-1 v2.0 on current epidemic HIV-1 variants

被引:18
作者
Mourez, Thomas [1 ,2 ,3 ]
Delaugerre, Constance [4 ,5 ]
Vray, Muriel [6 ]
Lemee, Veronique [3 ]
Simon, Francois [4 ,5 ]
Plantier, Jean-Christophe [1 ,2 ,3 ]
机构
[1] Normandie Univ, Caen, France
[2] Univ Rouen, IRIB, Equipe Accueil 2656, F-76183 Rouen, France
[3] CHU Rouen, Lab Virol, Associe Ctr Natl Reference VIH, F-76031 Rouen, France
[4] Univ Paris 07, F-75010 Paris, France
[5] Hop St Louis, AP HP, Lab Virol, F-75010 Paris, France
[6] Inst Pasteur, Unite Epidemiol Malad Emergentes, F-75014 Paris, France
关键词
HIV-1; Quantification; Genetic diversity; HIV-O; Viral load; IMMUNODEFICIENCY-VIRUS TYPE-1; GROUP-O; AMPLICOR; DISCREPANCIES; DIVERSITY; SUBTYPES; VERSION; IMPACT;
D O I
10.1016/j.jcv.2015.08.007
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Background: An improved version of the bioMerieux NucliSENS (R) EasyQ (R) HIV-1 v2.0 has been introduced to overcome the underquantification observed with previous versions, especially with non-B HIV-1 subtypes. Objectives: Comparing bioMerieux NucliSENS (R) EasyQ (R) HIV-1 v2.0 versus Roche Cobas CA/CTM v2.0 and Abbott RealTime HIV-1 assays for HIV-1 group M and non-M (N, O, P) viral load measurement. Study design: The three assays were tested in parallel on 103HIV-1 group M plasma samples, and on non-group M HIV-1 culture supernatants. Results: Values obtained for the 103HIV-1 group M plasma samples tested with bioMerieux assay showed good overall correlation compared to the 2 others. The Roche Cobas assay gave higher values than the bioMerieux assay, while Abbott and bioMerieux both displayed similar results. However, analysis showed a wider dispersion in results when comparing the bioMerieux NucliSENS (R) EasyQ (R) HIV-1 v2.0 and the other 2 techniques. All data taken into account, we observed frequent discrepancies in quantification, of the plasma samples and major differences above 1 log in 10/72 (13.8%). The quantification of non-M HIV groups in culture supernatant has shown variable results, with better quantification of HIV-O and of HIV-N respectively with the Abbott assay and the bioMerieux assay. Conclusions: The bioMerieux NucliSENS (R) EasyQ (R) HIV-1 v2.0 showed improved sensitivity to non-B HIV-M subtypes compared to previous versions. Notwithstanding, we observed frequent discrepancies and a wide dispersion in results when comparing bioMerieux NucliSENS (R) EasyQ (R) HIV-1 v2.0 and the other 2 techniques. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:76 / 81
页数:6
相关论文
共 50 条
  • [31] Performance of the ViroSeq HIV-1 genotyping system v2.0 on HIV-1 strains circulating in Senegal
    Thiam, Moussa
    Diop-Ndiaye, Halimatou
    Kebe, Khady
    Vidal, Nicole
    Diakhate-Lo, Rokhaya
    Diouara, Abou Abdallah Malick
    Leye, Nafissatou
    Ndiaye, Ousseynou
    Sow, Amina
    Ngom-Gueye, Ndeye Fatou
    Mboup, Souleymane
    Toure-Kane, Coumba
    JOURNAL OF VIROLOGICAL METHODS, 2013, 188 (1-2) : 97 - 103
  • [32] Comparison of the Abbott RealTime Human Immunodeficiency Virus Type 1 (HIV-1) Assay to the Cobas AmpliPrep/Cobas TaqMan HIV-1 Test: Workflow, Reliability, and Direct Costs
    Sloma, Cari R.
    Germer, Jeffrey J.
    Gerads, Tara M.
    Mandrekar, Jayawant N.
    Mitchell, P. Shawn
    Yao, Joseph D. C.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2009, 47 (04) : 889 - 895
  • [33] Evaluation of NucliSens EasyQ™ HIV-1 assay for quantification of HIV-1 subtypes prevalent in south-east Asia
    Lam, H. Y.
    Chen, J. H. K.
    Wong, K. H.
    Chan, K.
    Li, P.
    Lee, M. P.
    Tsang, D. N.
    Yuen, K. Y.
    Yam, W. C.
    JOURNAL OF CLINICAL VIROLOGY, 2007, 38 (01) : 39 - 43
  • [34] Evaluation of the Aptima® HIV-1 Quant Dx Assay for HIV-1 RNA Viral Load Detection and Quantitation in Plasma of HIV-1-Infected Individuals: A Comparison With Abbott RealTime HIV-1 Assay
    Amendola, Alessandra
    Pisciotta, Maria
    Aleo, Loredana
    Ferraioli, Valeria
    Angeletti, Claudio
    Capobianchi, Maria Rosaria
    JOURNAL OF MEDICAL VIROLOGY, 2016, 88 (09) : 1535 - 1544
  • [35] Evaluation of the Abbott Investigational Use Only RealTime HIV-1 Assay and Comparison to the Roche Amplicor HIV-1 Monitor Test, Version 1.5
    Pyne, Michael T.
    Konnick, Eric Q.
    Phansalkar, Amit
    Hillyard, David R.
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2009, 11 (04) : 347 - 354
  • [36] Comparison of the COBAS TAQMAN™ HIV-1HPS with VERSANT HIV-1 RNA 3.0 assay (bDNA) for plasma RNA quantitation indifferent HIV-1 subtypes
    Gomes, Perpetua
    Palma, Ana Carolina
    Cabanas, Joaquim
    Abecasis, Ana
    Carvalho, Ana Patricia
    Ziermann, Rainer
    Diogo, Isabel
    Gonçcalves, Fatima
    Lobo, Ceu Sousa
    Camacho, Ricardo
    JOURNAL OF VIROLOGICAL METHODS, 2006, 135 (02) : 223 - 228
  • [37] Comparison of the Generic HIV Viral Load® assay with the Amplicor™ HIV-1 Monitor v1.5 and Nuclisens HIV-1 EasyQ® v1.2 techniques for plasma HIV-1 RNA quantitation of non-B subtypes: The Kesho Bora preparatory study
    Rouet, Francois
    Foulongne, Vincent
    Viljoen, Johannes
    Steegen, Kim
    Becquart, Pierre
    Valea, Diane
    Danaviah, Sivapragashini
    Segondy, Michel
    Verhofstede, Chris
    Van de Perre, Philippe
    JOURNAL OF VIROLOGICAL METHODS, 2010, 163 (02) : 253 - 257
  • [38] Comparison of the rate and size of HIV-1 viral load blips with Roche COBAS TaqMan HIV-1 versions 1.0 and 2.0 and implications for patient management
    Garrett, Nigel J.
    Apea, Vanessa
    Nori, Achyuta
    Ushiro-Lumb, Ines
    Oliver, Anthony R.
    Baily, Guy
    Clark, Duncan A.
    JOURNAL OF CLINICAL VIROLOGY, 2012, 53 (04) : 354 - 355
  • [39] Comparison of Roche Cobas AmpliPrep/Cobas TaqMan HIV-1 test version 2.0 (CAP/CTM v2.0) with other real-time PCR assays in HIV-1 monitoring and follow-up of low-level viral loads
    Wojewoda, Christina M.
    Spahlinger, Timothy
    Harmon, Marlene Louise
    Schnellinger, Brian
    Li, Qing
    Dejelo, Corazon
    Schmotzer, Christine
    Zhou, Lan
    JOURNAL OF VIROLOGICAL METHODS, 2013, 187 (01) : 1 - 5
  • [40] Evaluation of the Roche Cobas TaqMan and Abbott RealTime extraction-quantification systems for HIV-1 subtypes
    Gueudin, Marie
    Plantier, Jean Christophe
    Lemee, Veronique
    Schmitt, Marie Paule
    Chartier, Loic
    Bourlet, Thomas
    Ruffault, Annick
    Damond, Florence
    Vray, Muriel
    Simon, Francois
    JAIDS-JOURNAL OF ACQUIRED IMMUNE DEFICIENCY SYNDROMES, 2007, 44 (05) : 500 - 505