Comparison of the bioMerieux NucliSENS EasyQ HIV-1 v2.0-HIV-1 RNA quantification assay versus Abbott RealTime HIV-1 and Roche Cobas TaqMan HIV-1 v2.0 on current epidemic HIV-1 variants

被引:19
作者
Mourez, Thomas [1 ,2 ,3 ]
Delaugerre, Constance [4 ,5 ]
Vray, Muriel [6 ]
Lemee, Veronique [3 ]
Simon, Francois [4 ,5 ]
Plantier, Jean-Christophe [1 ,2 ,3 ]
机构
[1] Normandie Univ, Caen, France
[2] Univ Rouen, IRIB, Equipe Accueil 2656, F-76183 Rouen, France
[3] CHU Rouen, Lab Virol, Associe Ctr Natl Reference VIH, F-76031 Rouen, France
[4] Univ Paris 07, F-75010 Paris, France
[5] Hop St Louis, AP HP, Lab Virol, F-75010 Paris, France
[6] Inst Pasteur, Unite Epidemiol Malad Emergentes, F-75014 Paris, France
关键词
HIV-1; Quantification; Genetic diversity; HIV-O; Viral load; IMMUNODEFICIENCY-VIRUS TYPE-1; GROUP-O; AMPLICOR; DISCREPANCIES; DIVERSITY; SUBTYPES; VERSION; IMPACT;
D O I
10.1016/j.jcv.2015.08.007
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Background: An improved version of the bioMerieux NucliSENS (R) EasyQ (R) HIV-1 v2.0 has been introduced to overcome the underquantification observed with previous versions, especially with non-B HIV-1 subtypes. Objectives: Comparing bioMerieux NucliSENS (R) EasyQ (R) HIV-1 v2.0 versus Roche Cobas CA/CTM v2.0 and Abbott RealTime HIV-1 assays for HIV-1 group M and non-M (N, O, P) viral load measurement. Study design: The three assays were tested in parallel on 103HIV-1 group M plasma samples, and on non-group M HIV-1 culture supernatants. Results: Values obtained for the 103HIV-1 group M plasma samples tested with bioMerieux assay showed good overall correlation compared to the 2 others. The Roche Cobas assay gave higher values than the bioMerieux assay, while Abbott and bioMerieux both displayed similar results. However, analysis showed a wider dispersion in results when comparing the bioMerieux NucliSENS (R) EasyQ (R) HIV-1 v2.0 and the other 2 techniques. All data taken into account, we observed frequent discrepancies in quantification, of the plasma samples and major differences above 1 log in 10/72 (13.8%). The quantification of non-M HIV groups in culture supernatant has shown variable results, with better quantification of HIV-O and of HIV-N respectively with the Abbott assay and the bioMerieux assay. Conclusions: The bioMerieux NucliSENS (R) EasyQ (R) HIV-1 v2.0 showed improved sensitivity to non-B HIV-M subtypes compared to previous versions. Notwithstanding, we observed frequent discrepancies and a wide dispersion in results when comparing bioMerieux NucliSENS (R) EasyQ (R) HIV-1 v2.0 and the other 2 techniques. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:76 / 81
页数:6
相关论文
共 22 条
[1]  
[Anonymous], 2010, Rapport 2010
[2]   HIV-1 Load Comparison Using Four Commercial Real-Time Assays [J].
Bourlet, Thomas ;
Signori-Schmuck, Anne ;
Roche, Laurent ;
Icard, Vinca ;
Saoudin, Henia ;
Trabaud, Mary-Anne ;
Tardy, Jean-Claude ;
Morand, Patrice ;
Pozzetto, Bruno ;
Ecochard, Rene ;
Andre, Patrice .
JOURNAL OF CLINICAL MICROBIOLOGY, 2011, 49 (01) :292-297
[3]   Human immunodeficiency virus type 1 (HIV-1) plasma load discrepancies between the Roche COBAS AMPLICOR HIV-1 MONITOR version 1.5 and the Roche COBAS AmpliPrep/COBAS TaqMan HIV-1 assays [J].
Damond, F. ;
Roquebert, B. ;
Benard, A. ;
Collin, G. ;
Miceli, A. ;
Yeni, P. ;
Brun-Vezinet, F. ;
Descamps, D. .
JOURNAL OF CLINICAL MICROBIOLOGY, 2007, 45 (10) :3436-3438
[4]   Evaluation of an Upgraded Version of the Roche Cobas AmpliPrep/Cobas TaqMan HIV-1 Test for HIV-1 Load Quantification [J].
Damond, F. ;
Avettand-Fenoel, V. ;
Collin, G. ;
Roquebert, B. ;
Plantier, J. C. ;
Ganon, A. ;
Sizmann, D. ;
Babiel, R. ;
Glaubitz, J. ;
Chaix, M. L. ;
Brun-Vezinet, F. ;
Descamps, D. ;
Rouzioux, C. .
JOURNAL OF CLINICAL MICROBIOLOGY, 2010, 48 (04) :1413-1416
[5]   Impact of Low-Level-Viremia on HIV-1 Drug-Resistance Evolution among Antiretroviral Treated-Patients [J].
Delaugerre, Constance ;
Gallien, Sebastien ;
Flandre, Philippe ;
Mathez, Dominique ;
Amarsy, Rishma ;
Ferret, Samuel ;
Timsit, Julie ;
Molina, Jean-Michel ;
de Truchis, Pierre .
PLOS ONE, 2012, 7 (05)
[6]   HIV-1 group N: travelling beyond Cameroon [J].
Delaugerre, Constance ;
De Oliveira, Fabienne ;
Lascoux-Combe, Caroline ;
Plantier, Jean-Christophe ;
Simon, Francois .
LANCET, 2011, 378 (9806) :1894-1894
[7]   Clinical and Resistance Consequences of Misquantification of Plasma and Cerebrospinal Fluid Human Immunodeficiency Virus Type 1 (HIV-1) RNA in Samples from an HIV-1 Subtype G-Infected Patient [J].
Delaugerre, Constance ;
Denis, Blandine ;
Peytavin, Gilles ;
Palmer, Pierre ;
Mourez, Thomas ;
Le Goff, Jerome ;
Molina, Jean-Michel ;
Simon, Francois .
JOURNAL OF CLINICAL MICROBIOLOGY, 2009, 47 (11) :3763-3764
[8]  
Gomes P., 2013, J VIROL METHODS
[9]  
Gueudin M., 2007, J ACQ IMMUN DEF SYND, V44, P500
[10]   A New Real-Time Quantitative PCR for Diagnosis and Monitoring of HIV-1 Group O Infection [J].
Gueudin, Marie ;
Leoz, Marie ;
Lemee, Veronique ;
De Oliveira, Fabienne ;
Vessiere, Aurelia ;
Kfutwah, Anfumbom ;
Plantier, Jean-Christophe .
JOURNAL OF CLINICAL MICROBIOLOGY, 2012, 50 (03) :831-836