Radiofrequency Thermal Ablation Heat Energy Transfer in an Ex-Vivo Model

被引:1
|
作者
Thakur, Shivani [1 ,2 ]
Lavito, Sandi [2 ]
Grobner, Elizabeth [3 ]
Grobner, Mark [2 ]
机构
[1] Harvard Univ, Cambridge, MA 02138 USA
[2] Calif State Univ Stanislaus, 1841 Trail Way, Turlock, CA 95382 USA
[3] Merced Jr Coll, Merced, CA USA
关键词
CHRONIC VENOUS DISEASE; TISSUE; NEUROPATHY; GAIT;
D O I
暂无
中图分类号
R61 [外科手术学];
学科分类号
摘要
Little work has been done to consider the temperature changes and energy transfer that occur in the tissue outside the vein with ultrasound-guided vein ablation therapy. In this experiment, a ex-vivo model of the human calf was used to analyze heat transfer and energy degradation in tissue surrounding the vein during endovascular radiofrequency ablation (RFA). A clinical vein ablation protocol was used to determine the tissue temperature distribution in 10 per cent agar gel. Heat energy from the radiofrequency catheter was measured for 140 seconds at fixed points by four thermometer probes placed equidistant radially at 0.0025, 0.005, and 0.01 m away from the RFA catheter. The temperature rose 1.5 degrees C at 0.0025 m, 0.6 degrees C at 0.005 m, and 0.0 degrees C at 0.01 m from the RFA catheter. There was a clinically insignificant heat transfer at the distances evaluated, 1.4 +/- 0.2 J/s at 0.0025 m, 0.7 +/- 0.3 J/s at 0.0050 m, and 0.3 +/- 0.0 J/s at 0.01 m. Heat degradation occurred rapidly: 4.5 +/- 0.5 J (at 0.0025 m), 4.0 +/- 1.6 J (at 0.0050 m), and 3.9 +/- 3.6 J (at 0.01 m). Tumescent anesthesia injected one centimeter around the vein would act as a heat sink to absorb the energy transferred outside the vein to minimize tissue and nerve damage and will help phlebologists strategize options for minimizing damage.
引用
收藏
页码:1373 / 1380
页数:8
相关论文
共 50 条
  • [21] Silicon Carbide-Enhanced Microwave Ablation in an Ex-Vivo Bovine Liver Model - Effects on Heat Distribution and Ablation Volume
    Isfort, P.
    Penzkofer, T.
    Bruners, P.
    Schmitz-Rode, T.
    Kuhl, C. K.
    Mahnken, A. H.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2012, 184 (06): : 542 - 547
  • [22] Mathematical and Ex Vivo Thermal Modeling for Renal Tumor Radiofrequency Ablation with Pyeloperfusion
    Glamore, Michael
    Masterson, Thomas
    Pease, Karli J.
    Lorber, Gideon
    Nella, Kevin
    Salas, Nelson
    Leveillee, Raymond J.
    JOURNAL OF ENDOUROLOGY, 2015, 29 (06) : 707 - 713
  • [23] EX VIVO LIVER TISSUE RADIOFREQUENCY THERMAL ABLATION: IR MEASUREMENTS AND SIMULATIONS
    Macchi, Edoardo Gino
    Braschi, Giovanni
    Gallati, Mario
    FRONTIERS IN HEAT AND MASS TRANSFER, 2014, 5
  • [24] Moving-Shot versus Fixed Electrode Techniques for Radiofrequency Ablation: Comparison in an Ex-Vivo Bovine Liver Tissue Model
    Ha, Eun Ju
    Baek, Jung Hwan
    Lee, Jeong Hyun
    KOREAN JOURNAL OF RADIOLOGY, 2014, 15 (06) : 836 - 843
  • [25] Unidirectional Ablation Electrode to Minimize Thermal Injury During Radiofrequency Ablation: An Experimental Study in an Ex Vivo Bovine Liver Model
    Na, Dong Gyu
    Lee, Jeong Hyun
    Kim, Sun Mi
    Lim, Hyun Kyung
    Baek, Jung Hwan
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2011, 22 (07) : 935 - 940
  • [26] Comparison of the tissue interaction between thermal ablation and cryotherapy as treatment for cervical precancerous lesions in an ex-vivo model
    de Fouw, M.
    Oosting, R. M.
    Eijkel, B. I. M.
    van Altena, P. F. J.
    Peters, A. A. W.
    Dankelman, J.
    Beltman, J. J.
    HEALTH AND TECHNOLOGY, 2020, 10 (05) : 1275 - 1281
  • [27] Novel balloon catheter-based endobiliary radiofrequency ablation system: Ex-vivo experimental study
    Inoue, Tadahisa
    Ito, Kiyoaki
    Yoneda, Masashi
    DIGESTIVE ENDOSCOPY, 2020, 32 (06) : 974 - 978
  • [28] The force stability of tissue contact and lesion size index during radiofrequency ablation: An ex-vivo study
    Parwani, Abdul S.
    Hohendanner, Felix
    Bode, David
    Kuhlmann, Stefan
    Blaschke, Florian
    Lacour, Philipp
    Heinzel, Frank R.
    Pieske, Burkert
    Boldt, Leif-Hendrik
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2020, 43 (03): : 327 - 331
  • [29] NOVEL BALLOON CATHETER-BASED ENDOBILIARY RADIOFREQUENCY ABLATION SYSTEM: AN EX-VIVO EXPERIMENTAL STUDY
    Inoue, Tadahisa
    Ito, Kiyoaki
    Yoneda, Masashi
    GASTROINTESTINAL ENDOSCOPY, 2020, 91 (06) : AB385 - AB385
  • [30] Stiffness distribution in the ablated zone after radiofrequency ablation for liver: An ex-vivo study with a tissue elastometer
    Guo, Le-Hang
    Wang, Dan
    Li, Xiao-Long
    Liu, Bo-Ji
    Chen, Shigao
    Li, Dan-Dan
    Xu, Hui-Xiong
    CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2019, 72 (02) : 151 - 160