Measurement of neutron ambient dose equivalent in passive carbon-ion and proton radiotherapies

被引:77
作者
Yonai, Shunsuke [1 ]
Matsufuji, Naruhiro [1 ]
Kanai, Tatsuaki [1 ]
Matsui, Yuki [2 ]
Matsushita, Kaoru [2 ]
Yamashita, Haruo [3 ]
Numano, Masumi [3 ]
Sakae, Takeji [4 ]
Terunuma, Toshiyuki [4 ]
Nishio, Teiji [5 ]
Kohno, Ryosuke [5 ]
Akagi, Takashi [6 ]
机构
[1] Natl Inst Radiol Sci, Inage Ku, Chiba 2638555, Japan
[2] Tokyo Inst Technol, Midori Ku, Yokohama, Kanagawa 2268503, Japan
[3] Shizuoka Canc Ctr, Nagaizumi, Shizuoka 4118777, Japan
[4] Univ Tsukuba, Proton Med Res Ctr, Tsukuba, Ibaraki 3050801, Japan
[5] Natl Canc Ctr Hosp E, Kashiwa, Chiba 2778577, Japan
[6] Hyogo Ion Beam Med Ctr, Tatsuno, Hyogo 6745165, Japan
关键词
secondary neutron; carbon-ion radiotherapy; proton radiotherapy;
D O I
10.1118/1.2989019
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Secondary neutron ambient dose equivalents per the treatment absorbed dose in passive carbon-ion and proton radiotherapies were measured using a rem meter, WENDI-II at two carbon-ion radiotherapy facilities and four proton radiotherapy facilities in Japan. Our measured results showed that (1) neutron ambient dose equivalent in carbon-ion radiotherapy is lower than that in proton radiotherapy, and (2) the difference to the measured neutron ambient dose equivalents among the facilities is within a factor of 3 depending on the operational beam setting used at the facility and the arrangement of the beam line, regardless of the method for making a laterally uniform irradiation field: the double scattering method or the single-ring wobbling method. The reoptimization of the beam line in passive particle radiotherapy is an effective way to reduce the risk of secondary cancer because installing an adjustable precollimator and designing the beam line devices with consideration of their material, thickness and location, etc., can significantly reduce the neutron exposure. It was also found that the neutron ambient dose equivalent in passive particle radiotherapy is equal to or less than that in the photon radiotherapy. This result means that not only scanning particle radiotherapy but also passive particle radiotherapy can provide reduced exposure to normal tissues around the target volume without an accompanied increase in total body dose. (C) 2008 American Association of Physicists in Medicine. [DOI: 10.1118/ 1.2989019]
引用
收藏
页码:4782 / 4792
页数:11
相关论文
共 30 条
  • [1] [Anonymous], JPN J MED PHYS
  • [2] [Anonymous], 38 NCRP
  • [3] The neutron fluence and H*(10) response of the new LB 6411 rem counter
    Burgkhardt, B
    Fieg, G
    Klett, A
    Plewnia, A
    Siebert, BRL
    [J]. RADIATION PROTECTION DOSIMETRY, 1997, 70 (1-4) : 361 - 364
  • [4] Cross-section evaluations to 150 MeV for accelerator-driven systems and implementation in MCNPX
    Chadwick, MB
    Young, PG
    Chiba, S
    Frankle, SC
    Hale, GM
    Hughes, HG
    Koning, AJ
    Little, RC
    MacFarlane, RE
    Prael, RE
    Waters, LS
    [J]. NUCLEAR SCIENCE AND ENGINEERING, 1999, 131 (03) : 293 - 328
  • [5] Fluence to dose equivalent conversion data and effective quality factors for high energy neutrons
    Ferrari, A
    Pelliccioni, M
    [J]. RADIATION PROTECTION DOSIMETRY, 1998, 76 (04) : 215 - 224
  • [6] GOTTSCHALK B, 2006, INT J RADIAT ONCOL, V65, P1
  • [7] Neutron dose in scattered and scanned proton beams:: In regard to Eric J!Hall (int j radiat oncol biol phys 2006;65:1-7)
    Gottschalk, Bernard
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (05): : 1594 - 1594
  • [8] Intensity-modulated radiation therapy, protons, and the risk of second cancers
    Hall, Eric J.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 65 (01): : 1 - 7
  • [9] Measurements of secondary neutron dose from 15 MV and 18 MV IMRT
    Howell, RM
    Ferenci, MS
    Hertel, NE
    Fullerton, GD
    Fox, T
    Davis, LW
    [J]. RADIATION PROTECTION DOSIMETRY, 2005, 115 (1-4) : 508 - 512
  • [10] Investigation of secondary neutron dose for 18 MV dynamic MLC IMRT delivery
    Howell, RM
    Ferenci, MS
    Hertel, NE
    Fullerton, GD
    [J]. MEDICAL PHYSICS, 2005, 32 (03) : 786 - 793