INTEGRATED PHOSPHATE AND PH SENSING SYSTEM FOR WATER QUALITY MONITORING

被引:0
|
作者
Bowrothu, Renuka [1 ]
Schumann, Todd [1 ]
Kim, Haein [1 ]
Kim, Kyoung Tae [2 ]
Hwang, Sunghyun [1 ]
Lee, Yoonseok [1 ]
Yoon, Yong Kyu [1 ]
机构
[1] Univ Florida, Gainesville, FL 32611 USA
[2] Univ Washington, Bothell, WA USA
关键词
Antimony (Sb); Cobalt (Co); ion selective electrode (ISE); phosphate; pH; sensor; wireless module; Internet of Things (IoT);
D O I
10.1109/mems46641.2020.9056230
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Cobalt (Co) ion selective electrode (ISE) has been studied for selective phosphate detection. As the electromotive force (EMF) response of this electrode to phosphate is affected by surrounding pH conditions, it has not been readily utilized for in-situ monitoring. In this work, we present an integrated Co based phosphate and antimony (Sb) based pH sensing system, which enables us to monitor precise phosphorous concentration taking into account a local pH level in aqueous solution. Platinum is used as the reference electrode. An extremely broad sensing range of phosphate concentration with 9 orders of magnitude concentration ranging between 5x10(-3) to 5x10(-12) M is reported. The sensing sensitive of 5 pM is one of the best reported in this kind of sensors in literature. Also, simultaneous detection of pH and phosphate concentration is presented using integrated wireless Bluetooth module. The total area of the fabricated sensor is 4 cm(2).
引用
收藏
页码:713 / 716
页数:4
相关论文
共 50 条
  • [1] Integrated water quality monitoring system with pH, free chlorine, and temperature sensors
    Qin, Yiheng
    Alam, Arif U.
    Pan, Si
    Howlader, Matiar M. R.
    Ghosh, Raja
    Hu, Nan-Xing
    Jin, Hao
    Dong, Shurong
    Chen, Chih-Hung
    Deen, M. Jamal
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 255 : 781 - 790
  • [2] A portable sensing system for water quality monitoring
    Twomey, K.
    Stephens, M.
    Jasionek, G.
    Papkovsky, D.
    Ogurtsov, V.
    2011 IEEE SENSORS, 2011, : 1878 - 1880
  • [3] Water quality monitoring using a smart sensing system
    Charef, A
    Ghauch, A
    Baussand, P
    Martin-Bouyer, M
    MEASUREMENT, 2000, 28 (03) : 219 - 224
  • [4] An Integrated Optical Measurement System for Water Quality Monitoring
    Kellner, Karlheinz
    Posnicek, Thomas
    Brandl, Martin
    28TH EUROPEAN CONFERENCE ON SOLID-STATE TRANSDUCERS (EUROSENSORS 2014), 2014, 87 : 1306 - 1309
  • [5] Water quality monitoring by nanostructured films in a sensing unit system
    Cajuela, Kassia Barbosa
    Dauer, Paaron Guenka
    Rosa, Miria Camargo
    Cuba Teran, Francisco Javier
    Giacometti, Jose Alberto
    DESALINATION AND WATER TREATMENT, 2012, 40 (1-3) : 209 - 214
  • [6] Integrated intelligent system for water quality monitoring and theft detection
    Karthikeyan, V
    Visu, Y. Palin
    Raja, E.
    WATER PRACTICE AND TECHNOLOGY, 2023, 18 (12) : 3035 - 3047
  • [7] A high-performance pH-sensitive electrode integrated with a multi-sensing probe for online water quality monitoring
    Uppuluri, Kiranmai
    Szwagierczak, Dorota
    Fernandes, Llewellyn
    Zaraska, Krzysztof
    Lange, Ilja
    Synkiewicz-Musialska, Beata
    Manjakkal, Libu
    JOURNAL OF MATERIALS CHEMISTRY C, 2023, 11 (44) : 15512 - 15520
  • [8] TEMPSENSE: LoRa Enabled Integrated Sensing and Localization Solution for Water Quality Monitoring
    Baghel, Lalit Kumar
    Gautam, Sukriti
    Malav, Vikas Kumar
    Kumar, Suman
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2022, 71
  • [9] INTEGRATED SYSTEM FOR ESOPHAGEAL PH MONITORING
    LEE, RJ
    CONNOLLY, RJ
    RAMENOFSKY, ML
    LEAPE, LL
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1979, 26 (09) : 526 - 526
  • [10] Design of Optical Fiber SPR Sensing System for Water Quality Monitoring
    Jiang, Xuehua
    Meng, Qingmin
    PROCEEDINGS OF THE 2015 INTERNATIONAL CONFERENCE ON COMPUTATIONAL SCIENCE AND ENGINEERING, 2015, 17 : 123 - 127