Association between Choroidal Thickness and Ocular Perfusion Pressure in Young, Healthy Subjects: Enhanced Depth Imaging Optical Coherence Tomography Study

被引:93
|
作者
Kim, Min [1 ]
Kim, Sung Soo [1 ]
Kwon, Hee Jung [1 ]
Koh, Hyoung Jun [2 ]
Lee, Sung Chul [1 ]
机构
[1] Yonsei Univ, Coll Med, Inst Vis Res, Dept Ophthalmol,Severance Eye & ENT Hosp, Seoul, South Korea
[2] Yonsei Univ, Coll Med, Dept Ophthalmol, Human Barrier Res Inst,Gangnam Severance Hosp, Seoul, South Korea
关键词
BLOOD-FLOW REGULATION; NERVE HEAD; AXIAL LENGTH; INTRAOCULAR-PRESSURE; MYOPIA; DEPENDENCE; GLAUCOMA; SCLERA;
D O I
10.1167/iovs.12-10464
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To investigate the correlation of choroidal thickness (CT) with ocular perfusion pressure (OPP) in young, healthy subjects using enhanced depth imaging optical coherence tomography (EDI-OCT). METHODS. A single horizontal section and a single vertical section of EDI-OCT scans in each eye of 69 young, healthy subjects were obtained at the macula. CT was measured at the fovea, and up to 3 mm, at intervals of 0.5 mm, away from the fovea in the superior, inferior, nasal, and temporal choroid. Univariable and multivariable analyses were performed to assess the association of CT with OPP while axial length (AL), refractive error (RE), sex, and/or body mass index (BMI), were taken into consideration. RESULTS. Mean subfoveal CT was 307.03 +/- 91.27 mu m (mean age, 22.3 +/- 3 years; mean axial length, 25.35 +/- 1.14 mm; mean refractive error, -3.89 +/- 2.02 diopters; mean OPP, 44.18 +/- 5.49 mm Hg). Multivariable regression analysis showed that in eyes with <6 diopters of myopia, subfoveal CT (325.92 +/- 88.46 mu m) changed most significantly in association with RE and mean OPP (beta = 25.941, P < 0.001; beta = -3.551, P = 0.042, respectively; adjusted R-2 = 0.249). In subjects with myopia of >6 diopters, subfoveal CT (225.17 +/- 49.37 mu m) was significantly thinner (P < 0.0001), and a significant correlation with OPP was not observed (P > 0.05). CONCLUSIONS. In vivo subfoveal CT as measured by EDI-OCT was significantly associated with OPP in young, healthy subjects when adjusted for RE, suggesting that subfoveal CT may be indirectly indicative of subfoveal ocular perfusion status. This association was not observed in subjects with high myopia. (Invest Ophthalmol Vis Sci. 2012;53:7710-7717) DOI: 10.1167/iovs.12-10464
引用
收藏
页码:7710 / 7717
页数:8
相关论文
共 50 条
  • [1] Lack of Association between Glaucoma and Macular Choroidal Thickness Measured with Enhanced Depth-Imaging Optical Coherence Tomography
    Mwanza, Jean-Claude
    Hochberg, Jessica T.
    Banitt, Michael R.
    Feuer, William J.
    Budenz, Donald L.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (06) : 3430 - 3435
  • [2] Analysis of choroidal thickness in ocular hypertensive patients using enhanced depth imaging optical coherence tomography
    Lin, Zhongjing
    Huang, Shouyue
    Huang, Ping
    Guo, Lei
    Bian, Hongjun
    Zhong, Yisheng
    LASERS IN MEDICAL SCIENCE, 2018, 33 (01) : 111 - 121
  • [3] Correlation between choroidal thickness and degree of myopia assessed with enhanced depth imaging optical coherence tomography
    El-Shazly, Amany A.
    Farweez, Yousra A.
    ElSebaay, Marwa E.
    El-Zawahry, Walid M. A.
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2017, 27 (05) : 577 - 584
  • [4] Repeatability of Manual Subfoveal Choroidal Thickness Measurements in Healthy Subjects Using the Technique of Enhanced Depth Imaging Optical Coherence Tomography
    Rahman, Waheeda
    Chen, Fred Kuanfu
    Yeoh, Jonathan
    Patel, Praveen
    Tufail, Adnan
    Da Cruz, Lyndon
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (05) : 2267 - 2271
  • [5] Measurement of Subfoveal Choroidal Thickness in Pseudoexfoliation Syndrome Using Enhanced Depth Imaging Optical Coherence Tomography
    Turan-Vural, Ece
    Yenerel, Nursal
    Okutucu, Murat
    Yildiz, Elvin
    Dikmen, Nejla
    OPHTHALMOLOGICA, 2015, 233 (3-4) : 204 - 208
  • [6] Choroidal Thickness in Myopic and Nonmyopic Children Assessed With Enhanced Depth Imaging Optical Coherence Tomography
    Read, Scott A.
    Collins, Michael J.
    Vincent, Stephen J.
    Alonso-Caneiro, David
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (12) : 7578 - 7586
  • [7] Choroidal Thickness Measurement in Myopic Eyes by Enhanced Depth Optical Coherence Tomography
    Ho, Mary
    Liu, David T. L.
    Chan, Vesta C. K.
    Lam, Dennis S. C.
    OPHTHALMOLOGY, 2013, 120 (09) : 1909 - 1914
  • [8] Enhanced Depth Imaging Optical Coherence Tomography: A New Way Measuring Choroidal Thickness in Pregnant Women
    Zhang, Jun
    Wang, Huiyun
    Yu, Qiubo
    Tong, Qihu
    Lu, Qinkang
    JOURNAL OF OPHTHALMOLOGY, 2017, 2017
  • [9] CHOROIDAL THICKNESS IN RELATION TO ETHNICITY MEASURED USING ENHANCED DEPTH IMAGING OPTICAL COHERENCE TOMOGRAPHY
    Karapetyan, Anushavan
    Ouyang, Pingbo
    Tang, Luo Sheng
    Gemilyan, Manik
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2016, 36 (01): : 82 - 90
  • [10] Relationship Between Retinal Perfusion and Retinal Thickness in Healthy Subjects: An Optical Coherence Tomography Angiography Study
    Yu, Jian
    Gu, Ruiping
    Zong, Yuan
    Xu, Huan
    Wang, Xiaolei
    Sun, Xinghuai
    Jiang, Chunhui
    Xie, Bing
    Jia, Yali
    Huang, David
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (09) : OCT204 - OCT210