Preliminary characterisation of new glass reference materials (GSA-1G, GSC-1G, GSD-1G and GSE-1G) by laser ablation-inductively coupled plasma-mass spectrometry using 193 nm, 213 nm and 266 nm wavelengths

被引:175
作者
Guillong, M
Hametner, K
Reusser, E
Wilson, SA
Günther, D
机构
[1] Swiss Fed Inst Technol, Inorgan Chem Lab, CH-8093 Zurich, Switzerland
[2] ETH Zentrum, Inst Mineral & Petrog, CH-8092 Zurich, Switzerland
[3] US Geol Survey, Denver, CO 80225 USA
关键词
laser ablation-inductively coupled plasma-mass spectrometry electron microprobe; glass reference materials; NIST SRM 610; USGS BCR-2G;
D O I
10.1111/j.1751-908X.2005.tb00903.x
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
New glass reference materials GSA-1G, GSC-1G, GSD-1G and GSE-1G have been characterised using a prototype solid state laser ablation system capable of producing wavelengths of 193 rim, 213 nm and 266 nm. This system allowed comparison of the effects of different laser wavelengths under nearly identical ablation and ICP operating conditions. The wavelengths 213 nm and 266 nm were also used at higher energy densities to evaluate the influence of energy density on quantitative analysis. in addition, the glass reference materials were analysed using commercially available 266 nm Nd:YAG and 193 nm ArF excimer lasers. Laser ablation analysis was carried out using both single spot and scanning mode ablation. Using laser ablation ICP-MS, concentrations of fifty-eight elements were determined with external calibration to the NIST SRM 610 glass reference material. instead of applying the more common internal standardisation procedure, the total concentration of all element oxide concentrations was normalised to 100%. Major element concentrations were compared with those determined by electron microprobe. in addition to NIST SRM 610 for external calibration, USGS BCR-2G was used as a more closely matrix-matched reference material in order to compare the effect of matrix-matched and non matrix-matched calibration on quantitative analysis. The results show that the various laser wavelengths and energy densities applied produced similar results, with the exception of scanning mode ablation at 266 nm without matrix-matched calibration where deviations up to 60% from the average were found. However, results acquired using a scanning mode with a matrix-matched calibration agreed with results obtained by spot analysis. The increased abundance of large particles produced when using a scanning ablation mode with NIST SRM 610, is responsible for elemental fractionation effects caused by incomplete vaporisation of large particles in the ICP.
引用
收藏
页码:315 / 331
页数:17
相关论文
共 25 条
[1]   High-speed digital photographic study of an inductively coupled plasma during laser ablation: comparison of dried solution aerosols from a microconcentric nebulizer and solid particles from laser ablation [J].
Aeschliman, DB ;
Bajic, SJ ;
Baldwin, DP ;
Houk, RS .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2003, 18 (09) :1008-1014
[2]   Compositional heterogeneity in NIST SRM 610-617 glasses [J].
Eggins, SM ;
Shelley, JMG .
GEOSTANDARDS NEWSLETTER-THE JOURNAL OF GEOSTANDARDS AND GEOANALYSIS, 2002, 26 (03) :269-286
[3]   Determination of forty two major and trace elements in USGS and NIST SRM glasses by laser ablation-inductively coupled plasma-mass spectrometry [J].
Gao, S ;
Liu, XM ;
Yuan, HL ;
Hattendorf, B ;
Günther, D ;
Chen, L ;
Hu, SH .
GEOSTANDARDS NEWSLETTER-THE JOURNAL OF GEOSTANDARDS AND GEOANALYSIS, 2002, 26 (02) :181-196
[4]   Application of a particle separation device to reduce inductively coupled plasma-enhanced elemental fractionation in laser ablation-inductively coupled plasma-mass spectrometry [J].
Guillong, M ;
Kuhn, HR ;
Günther, D .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2003, 58 (02) :211-220
[5]   A comparison of 266 nm, 213 nm and 193 nm produced from a single solid state Nd:YAG laser for laser ablation ICP-MS [J].
Guillong, M ;
Horn, I ;
Günther, D .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2003, 18 (10) :1224-1230
[6]   Effect of particle size distribution on ICP-induced elemental fractionation in laser ablation-inductively coupled plasma-mass spectrometry [J].
Guillong, M ;
Günther, D .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (08) :831-837
[7]   Capabilities of a homogenized 266 nm Nd:YAG laser ablation system for LA-ICP-MS [J].
Guillong, M ;
Horn, I ;
Günther, D .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (01) :8-14
[8]  
HALLOCHER K, 1995, GEOSTANDARD NEWSLETT, V19, P27
[9]   NIST SRM 610, 611 and SRM 612, 613 multi-element glasses: Constraints from element abundance ratios measured by microprobe techniques [J].
Hinton, RW .
GEOSTANDARDS NEWSLETTER-THE JOURNAL OF GEOSTANDARDS AND GEOANALYSIS, 1999, 23 (02) :197-207
[10]   Evaluation and design of a solid-state 193 nm OPO-Nd:YAG laser ablation system [J].
Horn, I ;
Günther, D ;
Guillong, M .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2003, 58 (10) :1837-1846