共 20 条
Direct MR arthrography of the shoulder under axial traction: Feasibility study to evaluate the superior labrum-biceps tendon complex and articular cartilage
被引:19
作者:
Becce, Fabio
[1
]
Richarme, Delphine
[1
]
Omoumi, Patrick
[2
]
Djahangiri, Ali
[3
]
Farron, Alain
[3
]
Meuli, Reto
[1
]
Theumann, Nicolas
[4
]
机构:
[1] Univ Lausanne, CHU Vaudois, Dept Diagnost & Intervent Radiol, CH-1011 Lausanne, Switzerland
[2] Catholic Univ Louvain, Clin Univ St Luc, Dept Radiol, B-1200 Brussels, Belgium
[3] Univ Lausanne, CHU Vaudois, Dept Orthopaed Surg & Traumatol, CH-1011 Lausanne, Switzerland
[4] Clin Hirslanden Bois Cerf, Dept Radiol, CH-1006 Lausanne, Switzerland
关键词:
shoulder;
glenoid labrum;
biceps tendon;
cartilage;
MR arthrography;
traction;
MAGNETIC-RESONANCE ARTHROGRAPHY;
GLENOHUMERAL JOINT;
EXTERNAL ROTATION;
CT ARTHROGRAPHY;
GLENOID LABRUM;
3-T MRI;
LESIONS;
D O I:
10.1002/jmri.23824
中图分类号:
R8 [特种医学];
R445 [影像诊断学];
学科分类号:
1002 ;
100207 ;
1009 ;
摘要:
Purpose: To assess the value of adding axial traction to direct MR arthrography of the shoulder, in terms of subacromial and glenohumeral joint space widths, and coverage of the superior labrum-biceps tendon complex and articular cartilage by contrast material. Materials and Methods: Twenty-one patients investigated by direct MR arthrography of the shoulder were prospectively included. Studies were performed with a 3 Tesla (T) unit and included a three-dimensional isotropic fat-suppressed T1-weighted gradient-recalled echo sequence, without and with axial traction (4 kg). Two radiologists independently measured the width of the subacromial, superior, and inferior glenohumeral joint spaces. They subsequently rated the amount of contrast material around the superior labrum-biceps tendon complex and between glenohumeral cartilage surfaces, using a three-point scale: 0 = no, 1 = partial, 2 = full. Results: Under traction, the subacromial ( = 2.0 mm, P = 0.0003), superior ( = 0.7 mm, P = 0.0001) and inferior ( = 1.4 mm, P = 0.0006) glenohumeral joint space widths were all significantly increased, and both readers noted significantly more contrast material around the superior labrum-biceps tendon complex (P = 0.014), and between the superior (P = 0.001) and inferior (P = 0.025) glenohumeral cartilage surfaces. Conclusion: Direct MR arthrography of the shoulder under axial traction increases subacromial and glenohumeral joint space widths, and prompts better coverage of the superior labrum-biceps tendon complex and articular cartilage by contrast material. J. Magn. Reson. Imaging 2013;37:12281233. (c) 2012 Wiley Periodicals, Inc.
引用
收藏
页码:1228 / 1233
页数:6
相关论文