Percutaneous radiofrequency tissue ablation: Optimization of pulsed radiofrequency technique to increase coagulation necrosis

被引:247
作者
Goldberg, SN
Stein, MC
Gazelle, GS
Sheiman, RG
Kruskal, JB
Clouse, ME
机构
[1] Beth Israel Deaconess Med Ctr, Dept Radiol, Boston, MA 02215 USA
[2] Massachusetts Gen Hosp, Dept Radiol, Boston, MA 02114 USA
关键词
neoplasms; therapy; radiofrequency ablation;
D O I
10.1016/S1051-0443(99)70136-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To develop a computerized algorithm for pulsed, high-current percutaneous radiofrequency (RF) ablation, which maximally increases the extent of induced coagulation necrosis. MATERIALS AND METHODS: An automated, Programmable algorithm for pulsed-RF deposition was designed to permit high-current deposition by periodically reducing current for 5-30 seconds during RF application. Two strategies for pulsed-RF deposition were evaluated: (i) constant peak current (900-1,800 mA) of variable duration and (ii) variable peak current (1,200-2,000 mA) for a specified minimum duration. The extent of induced coagulation was compared to results obtained with continuous (lower current) RF application. Trials were performed in ex vivo calf liver (n = 115) and in vivo porcine liver (n = 30) and muscle (n = 18) with use of 2-4-cm tip, internally cooled electrodes. RESULTS: For 3-cm electrodes in ex vivo liver, applying pulsed-RF with constant peak current for 12 minutes produced 3.5 cm +/- 0.2 of necrosis, Greater necrosis was produced with use of the variable current strategy, in which 4.5 cm +/- 0.2 of coagulation was achieved with use of an initial current greater than or equal to 1,500 mA (minimum peak-RF duration of 10 sec, with 15 sec of reduced current to 100 mA between peaks; P < .01). This variable peak current algorithm also produced 3.7 cm +/- 0.6 of necrosis in in vivo liver, and 6.5 cm +/- 0.9 in in vivo muscle. Without pulsing, a maximum of 750 mA, 1,100 mA, and 1,500 mA could be applied in ex vivo liver, in vivo liver, and in vivo muscle, respectively, which resulted in 2.9 cm +/- 0.2, 2.4 cm +/- 0.2, and 5.1 cm +/- 0.4 of coagulation (P < .05, all comparisons). CONCLUSIONS: A variable peak current algorithm for pulsed-RF deposition can increase coagulation necrosis diameter over other ablation strategies. This innovation may ultimately enable the percutaneous treatment of larger tumors.
引用
收藏
页码:907 / 916
页数:10
相关论文
共 23 条
  • [21] Hepatic metastases: Percutaneous radio-frequency ablation with cooled-tip electrodes
    Solbiati, L
    Goldberg, SN
    Ierace, T
    Livraghi, T
    Meloni, F
    Dellanoce, M
    Sironi, S
    Gazelle, GS
    [J]. RADIOLOGY, 1997, 205 (02) : 367 - 373
  • [22] Solbiati L, 1997, RADIOLOGY, V205, P254
  • [23] Radiofrequency interstitial tumor ablation (RITA) is a possible new modality for treatment of renal cancer: Ex vivo and in vivo experience
    Zlotta, AR
    Wildschutz, T
    Raviv, G
    Peny, MO
    vanGansbeke, D
    Noel, JC
    Schulman, CC
    [J]. JOURNAL OF ENDOUROLOGY, 1997, 11 (04) : 251 - 258