Investigation of Non-Enzymatic Glycosylation of Human Serum Albumin Using Ion Trap-Time of Flight Mass Spectrometry

被引:30
|
作者
Bai, Xue [2 ]
Wang, Zhangjie [1 ]
Huang, Chengcai [3 ]
Wang, Zhe [4 ]
Chi, Lianli [1 ,2 ]
机构
[1] Shandong Univ, State Key Lab Microbial Technol, Jinan 250100, Shandong, Peoples R China
[2] Shandong Univ, Natl Glycoengn Res Ctr, Jinan 250100, Shandong, Peoples R China
[3] Shimadzu Int Inc, Life Sci & Clin Dept, Beijing 100020, Peoples R China
[4] Shandong Univ, Prov Hosp, Div Endocrinol & Metab, Jinan 250100, Shandong, Peoples R China
关键词
glycation; human serum albumin; ion trap-time of flight; mass spectrometry; peptide fingerprinting; diabetes; incorporation ratio; PERFORMANCE LIQUID-CHROMATOGRAPHY; GLYCATED ALBUMIN; AFFINITY-CHROMATOGRAPHY; IDENTIFICATION; PROTEIN; SYSTEM; ELECTROPHORESIS; SITE;
D O I
10.3390/molecules17088782
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Non-enzymatic glycosylation or glycation involves covalent attachment of reducing sugar residues to proteins without enzyme participation. Glycation of glucose to human serum albumin in vivo is related to diabetes and many other diseases. We present an approach using liquid chromatography coupled to an electrospray ionization source of a hybrid ion trap-time of flight (IT-TOF-MS/MS) tandem mass spectrometer to identify the glycation sites on serum albumin from both a healthy person and a diabetic patient. The MetID software, which is commonly used for screening metabolites, is adapted for peptide fingerprinting based on both m/z values and isotopic distribution profiles. A total of 21 glycation sites from the healthy person and 16 glycation sites from the diabetic patient were identified successfully. We also demonstrate the use of matrix assisted laser desorption ionization-time of flight mass spectrometry to estimate the incorporation ratio of glucose to albumin during glycation. Results from this study show that the glycation in healthy person is more complicated than previously thought. Further analysis of incorporation ratio distribution may be necessary to accurately reflect the change of serum albumin glycation in diabetic patients.
引用
收藏
页码:8782 / 8794
页数:13
相关论文
共 50 条
  • [41] Profiling and biomarker identification in plasma from different Zucker rat strains via high mass accuracy multistage mass spectrometric analysis using liquid chromatography/mass spectrometry with a quadrupole ion trap-time of flight mass spectrometer
    Loftus, Neil
    Miseki, Kozo
    Iida, Junko
    Gika, Helen G.
    Theodoridis, Georgios
    Wilson, Ian D.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2008, 22 (16) : 2547 - 2554
  • [42] Procedures for Tandem Mass Spectrometry on an Ion Trap Storage/Reflectron Time-of-flight Mass Spectrometer
    Qian, M. G.
    Lubman, D. M.
    Rapid Communications in Mass Spectrometry, 10 (15):
  • [43] Procedures for tandem mass spectrometry on an ion trap storage/reflectron time-of-flight mass spectrometer
    Qian, MG
    Lubman, DM
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1996, 10 (15) : 1911 - 1920
  • [44] Online sample pretreatment for analysis of decomposition products in lithium ion battery by liquid chromatography hyphenated with ion trap-time of flight-mass spectrometry or inductively coupled plasma-sector field-mass spectrometry
    Koesters, Kristina
    Henschel, Jonas
    Winter, Martin
    Nowak, Sascha
    JOURNAL OF CHROMATOGRAPHY A, 2021, 1658
  • [45] Investigation of molecular surfaces with time-of-flight secondary ion mass spectrometry
    Aoyagi, Satoka
    Namekawa, Koki
    Yamamoto, Kenichiro
    Sakai, Kiyotaka
    Kato, Nobuhiko
    Kudo, Masahiro
    SURFACE AND INTERFACE ANALYSIS, 2010, 42 (10-11) : 1593 - 1597
  • [46] A new linear ion trap time-of-flight system with tandem mass spectrometry capabilities
    Campbell, JM
    Collings, BA
    Douglas, DJ
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1998, 12 (20) : 1463 - 1474
  • [47] Structural analysis of quazepam metabolites in bile by ion trap time-of-flight mass spectrometry
    Yamaguchi, Koji
    Goda, Takahiro
    Yamaki, Satoshi
    Ohno, Youkichi
    FORENSIC SCIENCE INTERNATIONAL, 2015, 256 : 7 - 16
  • [48] Characterisation of selected hypnotic drugs and their metabolites using electrospray ionisation with ion trap mass spectrometry and with quadrupole time-of-flight mass spectrometry and their determination by liquid chromatography-electrospray ionisation-ion trap mass spectrometry
    Smyth, WF
    Joyce, C
    Ramachandran, VN
    O' Kane, E
    Coulter, D
    ANALYTICA CHIMICA ACTA, 2004, 506 (02) : 203 - 214
  • [49] Imaging of aerosols using time of flight secondary ion mass spectrometry
    Palma, Carolina Font
    Evans, Greg J.
    Sodhi, Rana N. S.
    APPLIED SURFACE SCIENCE, 2007, 253 (14) : 5951 - 5956
  • [50] Simulation of ion beam and optimization of orthogonal tandem ion trap/reflector time-of-flight mass spectrometry
    Marinach, C
    Brunot, A
    Beaugrand, C
    Bolbach, G
    Tabet, JC
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2002, 213 (01) : 45 - 62