Test-Retest Reliability of Portable Metabolic Monitoring After Disabling Stroke

被引:22
作者
Stookey, Alyssa D. [1 ]
McCusker, Michael G. [2 ]
Sorkin, John D. [1 ,2 ]
Katzel, Leslie I. [1 ,2 ]
Shaughnessy, Marianne [1 ,2 ]
Macko, Richard F. [1 ,2 ]
Ivey, Frederick M. [1 ,2 ]
机构
[1] Baltimore VA Med Ctr, Baltimore, MD USA
[2] Univ Maryland, Sch Med, Baltimore, MD 21201 USA
关键词
gait economy; oxygen consumption; hemiparesis; 6-MINUTE WALK; INDIVIDUALS; EXERCISE; FITNESS; GAIT; IMPAIRMENTS; DISTANCE; MILD;
D O I
10.1177/1545968313497103
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Purpose. Impaired economy of gait, prevalent in chronic stroke secondary to residual gait deficits, is associated with intolerance for performing activities of daily living. Gait economy/efficiency is traditionally assessed by determining the rate of oxygen consumption during submaximal treadmill walking. However, the mechanics and energetics of treadmill versus overground walking are very different in stroke survivors with ambulatory deficits. Clearly, overground cardiopulmonary measures are needed to accurately profile movement economy after stroke. An obstacle to obtaining such measures after stroke has been the absence of reliable portable metabolic monitoring equipment. The purpose of this study was to establish the test-retest reliability of a portable metabolic monitoring device during overground walking in hemiparetic stroke survivors. Methods. Twenty-three chronic hemiparetic stroke survivors underwent two 6-minute walk tests while wearing a COSMED K4b(2) portable metabolic measurement system. Intraclass correlations coefficients (ICC) were calculated for both cardiopulmonary parameters and distance covered to determine test-retest reliability. An ICC of 0.85 was considered reliable. Results. ICCs for relative Vo(2) (0.90), absolute Vo(2) (0.93), Vco(2) (0.93), and minute ventilation (0.95) demonstrated high reliability, but not for heart rate (0.76) or respiratory exchange ratio (0.64). There was no significant difference in the distance each participant walked between the first and second tests, eliminating distance as a potential confounder of our analyses (ICC = 0.99). Conclusions. Our results strongly support the reliability of the K4b(2) for quantifying overground gait efficiency after stroke. Use of this device may enable researchers to study how varying poststroke rehabilitation interventions affect this central measure of health and function.
引用
收藏
页码:872 / 877
页数:6
相关论文
共 50 条
  • [41] The test-retest reliability and concurrent validity of 360° turn test in patients with knee osteoarthritis
    Yarar, Haci Ahmet
    Narin, Selnur
    Erduran, Mehmet
    Gurbanov, Iftikhar
    SOMATOSENSORY AND MOTOR RESEARCH, 2024, 41 (02) : 90 - 96
  • [42] Test-Retest Reliability of the 6-Minute Walk Test in Individuals With Down Syndrome
    Casey, Amanda F.
    Wang, Xu
    Osterling, Kristin
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2012, 93 (11): : 2068 - 2074
  • [43] Test-retest reliability and criterion validity of a new Taekwondo Anaerobic Intermittent Kick Test
    Tayech, Amel
    Mejri, Mohamed A.
    Chaabene, Helmi
    Chaouachi, Mehdi
    Behm, David G.
    Chaouachi, Anis
    JOURNAL OF SPORTS MEDICINE AND PHYSICAL FITNESS, 2019, 59 (02) : 230 - 237
  • [44] The test-retest reliability and limits of agreement of the balance evaluation systems test (BESTest) in young people with intellectual disability
    Bahiraei, Saeid
    Hosseini, Elham
    Lou, Rahman Amiri Jomi
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [45] Test-retest reliability of hand-held dynamometry and functional tests in systemic lupus erythematosus
    Stockton, K. A.
    Wrigley, T. V.
    Mengersen, K. A.
    Kandiah, D. A.
    Paratz, J. D.
    Bennell, K. L.
    LUPUS, 2011, 20 (02) : 144 - 150
  • [46] Accuracy, concurrent validity, and test-retest reliability of pressure-based insoles for gait measurement in chronic stroke patients
    Neumann, Saskia
    Bauer, Christoph M.
    Nastasi, Luca
    Laderach, Julia
    Thurlimann, Eva
    Schwarz, Anne
    Held, Jeremia P. O.
    Easthope, Chris A.
    FRONTIERS IN DIGITAL HEALTH, 2024, 6
  • [47] Test-retest reliability and four-week changes in cardiopulmonary fitness in stroke patients: evaluation using a robotics-assisted tilt table
    Saengsuwan, Jittima
    Berger, Lucia
    Schuster-Amft, Corina
    Nef, Tobias
    Hunt, Kenneth J.
    BMC NEUROLOGY, 2016, 16
  • [48] Inter-rater and test-retest reliability of the seated multidirectional reach test in wheelchair basketball players: A clinical field test
    Bogado, Diego J.
    Boscarol, Kevin A.
    Blajman, Jesica E.
    E-BALONMANO COM, 2025, 21 (01): : 65 - 76
  • [49] The test-retest reliability of physiological and perceptual responses during treadmill load carriage
    Vickery-Howe, Danielle M.
    Dascombe, Ben J.
    Clarke, Anthea C.
    Drain, Jace R.
    Huynh, Minh
    Middleton, Kane J.
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2024, 124 (07) : 2093 - 2100
  • [50] Test-Retest Reliability of the Tower of London Planning Task (TOL-F)
    Koestering, Lena
    Nitschke, Kai
    Schumacher, F. Konrad
    Weiller, Cornelius
    Kaller, Christoph P.
    PSYCHOLOGICAL ASSESSMENT, 2015, 27 (03) : 925 - 931