Test-Retest Reliability of Portable Metabolic Monitoring After Disabling Stroke

被引:22
作者
Stookey, Alyssa D. [1 ]
McCusker, Michael G. [2 ]
Sorkin, John D. [1 ,2 ]
Katzel, Leslie I. [1 ,2 ]
Shaughnessy, Marianne [1 ,2 ]
Macko, Richard F. [1 ,2 ]
Ivey, Frederick M. [1 ,2 ]
机构
[1] Baltimore VA Med Ctr, Baltimore, MD USA
[2] Univ Maryland, Sch Med, Baltimore, MD 21201 USA
关键词
gait economy; oxygen consumption; hemiparesis; 6-MINUTE WALK; INDIVIDUALS; EXERCISE; FITNESS; GAIT; IMPAIRMENTS; DISTANCE; MILD;
D O I
10.1177/1545968313497103
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Purpose. Impaired economy of gait, prevalent in chronic stroke secondary to residual gait deficits, is associated with intolerance for performing activities of daily living. Gait economy/efficiency is traditionally assessed by determining the rate of oxygen consumption during submaximal treadmill walking. However, the mechanics and energetics of treadmill versus overground walking are very different in stroke survivors with ambulatory deficits. Clearly, overground cardiopulmonary measures are needed to accurately profile movement economy after stroke. An obstacle to obtaining such measures after stroke has been the absence of reliable portable metabolic monitoring equipment. The purpose of this study was to establish the test-retest reliability of a portable metabolic monitoring device during overground walking in hemiparetic stroke survivors. Methods. Twenty-three chronic hemiparetic stroke survivors underwent two 6-minute walk tests while wearing a COSMED K4b(2) portable metabolic measurement system. Intraclass correlations coefficients (ICC) were calculated for both cardiopulmonary parameters and distance covered to determine test-retest reliability. An ICC of 0.85 was considered reliable. Results. ICCs for relative Vo(2) (0.90), absolute Vo(2) (0.93), Vco(2) (0.93), and minute ventilation (0.95) demonstrated high reliability, but not for heart rate (0.76) or respiratory exchange ratio (0.64). There was no significant difference in the distance each participant walked between the first and second tests, eliminating distance as a potential confounder of our analyses (ICC = 0.99). Conclusions. Our results strongly support the reliability of the K4b(2) for quantifying overground gait efficiency after stroke. Use of this device may enable researchers to study how varying poststroke rehabilitation interventions affect this central measure of health and function.
引用
收藏
页码:872 / 877
页数:6
相关论文
共 50 条
  • [31] Test-Retest Reliability of the Mini-BESTest in People With Mild to Moderate Multiple Sclerosis
    Wallin, Andreas
    Kierkegaard, Marie
    Franzen, Erika
    Johansson, Sverker
    PHYSICAL THERAPY, 2021, 101 (05):
  • [32] Using wearable sensors to characterize gait after spinal cord injury: evaluation of test-retest reliability and construct validity
    Lemay, Jean-Francois
    Noamani, Alireza
    Unger, Janelle
    Houston, David J.
    Rouhani, Hossein
    Musselmann, Kristin E.
    SPINAL CORD, 2021, 59 (06) : 675 - 683
  • [33] Validity and test-retest reliability of the Stride Analyzer in people with knee osteoarthritis
    Beckwee, David
    Degelaen, Marc
    Eggermont, Matthias
    Gonzalez-Rodriguez, Miguel
    Lefeber, Nina
    Vaes, Peter
    Bautmans, Ivan
    Swinnen, Eva
    GAIT & POSTURE, 2016, 49 : 155 - 158
  • [34] Test-Retest Reliability of Respiratory Resistance Measured With the Airflow Perturbation Device
    Gallena, Sally K.
    Solomon, Nancy Pearl
    Johnson, Arthur T.
    Vossoughi, Jafar
    Tian, Wei
    JOURNAL OF SPEECH LANGUAGE AND HEARING RESEARCH, 2014, 57 (04): : 1323 - 1329
  • [35] Test-retest reliability of physical activity questionnaires in Parkinson’s disease
    Samuel Ånfors
    Ann-Sofi Kammerlind
    Maria H. Nilsson
    BMC Neurology, 21
  • [36] Test-Retest Reliability of Kinematic Assessments for Upper Limb Robotic Rehabilitation
    Koeppel, T.
    Pila, O.
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2020, 28 (09) : 2035 - 2042
  • [37] Test-retest reliability of the FitMáx©-questionnaire in a clinical and healthy population
    Meijer, Renske
    Schep, Goof
    Regis, Marta
    Papen-Botterhuis, Nicole E.
    Savelberg, Hans H. C. M.
    van Hooff, Martijn
    JOURNAL OF PATIENT-REPORTED OUTCOMES, 2024, 8 (01)
  • [38] Test-retest reliability of dynamic functional connectivity in resting state fMRI
    Zhang, Chao
    Baum, Stefi A.
    Adduru, Viraj R.
    Biswal, Bharat B.
    Michael, Andrew M.
    NEUROIMAGE, 2018, 183 : 907 - 918
  • [39] Test-retest reliability of the oxygen uptake efficiency slope in surgical patients
    Phypers, B. J.
    Robiony-Rogers, D.
    Pickering, R. M.
    Garden, A. L.
    ANAESTHESIA, 2011, 66 (08) : 659 - 666
  • [40] Test-retest agreement and reliability of the Six Spot Step Test in persons with multiple sclerosis
    Callesen, Jacob
    Richter, Christina
    Kristensen, Cecilie
    Sunesen, Inger
    Naesby, Marie
    Dalgas, Ulrik
    Skjerbaek, Anders Guldhammer