Test-Retest Reliability of Portable Metabolic Monitoring After Disabling Stroke

被引:22
作者
Stookey, Alyssa D. [1 ]
McCusker, Michael G. [2 ]
Sorkin, John D. [1 ,2 ]
Katzel, Leslie I. [1 ,2 ]
Shaughnessy, Marianne [1 ,2 ]
Macko, Richard F. [1 ,2 ]
Ivey, Frederick M. [1 ,2 ]
机构
[1] Baltimore VA Med Ctr, Baltimore, MD USA
[2] Univ Maryland, Sch Med, Baltimore, MD 21201 USA
关键词
gait economy; oxygen consumption; hemiparesis; 6-MINUTE WALK; INDIVIDUALS; EXERCISE; FITNESS; GAIT; IMPAIRMENTS; DISTANCE; MILD;
D O I
10.1177/1545968313497103
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Purpose. Impaired economy of gait, prevalent in chronic stroke secondary to residual gait deficits, is associated with intolerance for performing activities of daily living. Gait economy/efficiency is traditionally assessed by determining the rate of oxygen consumption during submaximal treadmill walking. However, the mechanics and energetics of treadmill versus overground walking are very different in stroke survivors with ambulatory deficits. Clearly, overground cardiopulmonary measures are needed to accurately profile movement economy after stroke. An obstacle to obtaining such measures after stroke has been the absence of reliable portable metabolic monitoring equipment. The purpose of this study was to establish the test-retest reliability of a portable metabolic monitoring device during overground walking in hemiparetic stroke survivors. Methods. Twenty-three chronic hemiparetic stroke survivors underwent two 6-minute walk tests while wearing a COSMED K4b(2) portable metabolic measurement system. Intraclass correlations coefficients (ICC) were calculated for both cardiopulmonary parameters and distance covered to determine test-retest reliability. An ICC of 0.85 was considered reliable. Results. ICCs for relative Vo(2) (0.90), absolute Vo(2) (0.93), Vco(2) (0.93), and minute ventilation (0.95) demonstrated high reliability, but not for heart rate (0.76) or respiratory exchange ratio (0.64). There was no significant difference in the distance each participant walked between the first and second tests, eliminating distance as a potential confounder of our analyses (ICC = 0.99). Conclusions. Our results strongly support the reliability of the K4b(2) for quantifying overground gait efficiency after stroke. Use of this device may enable researchers to study how varying poststroke rehabilitation interventions affect this central measure of health and function.
引用
收藏
页码:872 / 877
页数:6
相关论文
共 50 条
  • [21] Test-retest reliability, validity, and correlates of the 2-min walk test in outpatients with depression
    Vancampfort, Davy
    Basangwa, David
    Kimbowa, Samuel
    Firth, Joseph
    Schuch, Felipe
    Van Damme, Tine
    Mugisha, James
    PHYSIOTHERAPY RESEARCH INTERNATIONAL, 2020, 25 (02)
  • [22] Test-retest reliability of TRIMP in collegiate ice hockey players
    Ulmer, Jason G.
    Tomkinson, Grant R.
    Short, Sandra
    Short, Martin
    Fitzgerald, John S.
    BIOLOGY OF SPORT, 2019, 36 (02) : 191 - 194
  • [23] Test-retest reliability, feasibility and clinical correlates of the Eurofit test battery in people with bipolar disorder
    Vancampfort, Davy
    Sienaert, Pascal
    Wyckaert, Sabine
    De Hert, Marc
    Stubbs, Brendon
    Rosenbaum, Simon
    Buys, Roselien
    Probst, Michel
    PSYCHIATRY RESEARCH, 2015, 228 (03) : 620 - 625
  • [24] Test-retest reliability of the electromyographic fatigue threshold for cycle ergometry
    Mahmutovic, Selim
    Sprout, Erick Y.
    Fontaine, John C.
    Buskirk, Travis M.
    Galen, Sujay S.
    Malek, Moh H.
    MUSCLE & NERVE, 2016, 53 (05) : 803 - 807
  • [25] Test-retest Reliability of GPS derived Measurements in Patients with Claudication
    Gernigon, M.
    Fouasson-Chailloux, A.
    Colas-Ribas, C.
    Noury-Desvaux, B.
    Le Faucheur, A.
    Abraham, P.
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2015, 50 (05) : 623 - 629
  • [26] Test-retest reliability of the Brunel Lifestyle Physical Activity Questionnaire
    Vencato, Massimo M.
    Karageorghis, Costas I.
    Nevill, Alan M.
    Priest, David-Lee
    PSYCHOLOGY OF SPORT AND EXERCISE, 2017, 33 : 24 - 30
  • [27] Test-retest reliability of the Military Pre-training Questionnaire
    Robinson, M.
    Stokes, K.
    Bilzon, J.
    Standage, M.
    Brown, P.
    Thompson, D.
    OCCUPATIONAL MEDICINE-OXFORD, 2010, 60 (06): : 476 - 483
  • [28] Test-Retest Reliability and Construct Validity of the Tinetti Performance-Oriented Mobility Assessment in People With Stroke
    Canbek, Jennifer
    Fulk, George
    Nof, Leah
    Echternach, John
    JOURNAL OF NEUROLOGIC PHYSICAL THERAPY, 2013, 37 (01): : 14 - 19
  • [29] Intra-test and test-retest reliability of exercise oximetry in arterial claudication
    Henni, S.
    Sempore, Y. W.
    Le Meliner, T.
    Ouedraogo, N.
    Hamel, J. -F.
    Abraham, P.
    MICROVASCULAR RESEARCH, 2018, 117 : 44 - 49
  • [30] Test-retest reliability of the L-Test in patients with advanced knee osteoarthritis
    Nalbant, Abdurrahman
    Unver, Bayram
    Karatosun, Vasfi
    PHYSIOTHERAPY THEORY AND PRACTICE, 2022, 38 (13) : 2983 - 2987