Test-Retest Reliability of Portable Metabolic Monitoring After Disabling Stroke

被引:22
作者
Stookey, Alyssa D. [1 ]
McCusker, Michael G. [2 ]
Sorkin, John D. [1 ,2 ]
Katzel, Leslie I. [1 ,2 ]
Shaughnessy, Marianne [1 ,2 ]
Macko, Richard F. [1 ,2 ]
Ivey, Frederick M. [1 ,2 ]
机构
[1] Baltimore VA Med Ctr, Baltimore, MD USA
[2] Univ Maryland, Sch Med, Baltimore, MD 21201 USA
关键词
gait economy; oxygen consumption; hemiparesis; 6-MINUTE WALK; INDIVIDUALS; EXERCISE; FITNESS; GAIT; IMPAIRMENTS; DISTANCE; MILD;
D O I
10.1177/1545968313497103
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Purpose. Impaired economy of gait, prevalent in chronic stroke secondary to residual gait deficits, is associated with intolerance for performing activities of daily living. Gait economy/efficiency is traditionally assessed by determining the rate of oxygen consumption during submaximal treadmill walking. However, the mechanics and energetics of treadmill versus overground walking are very different in stroke survivors with ambulatory deficits. Clearly, overground cardiopulmonary measures are needed to accurately profile movement economy after stroke. An obstacle to obtaining such measures after stroke has been the absence of reliable portable metabolic monitoring equipment. The purpose of this study was to establish the test-retest reliability of a portable metabolic monitoring device during overground walking in hemiparetic stroke survivors. Methods. Twenty-three chronic hemiparetic stroke survivors underwent two 6-minute walk tests while wearing a COSMED K4b(2) portable metabolic measurement system. Intraclass correlations coefficients (ICC) were calculated for both cardiopulmonary parameters and distance covered to determine test-retest reliability. An ICC of 0.85 was considered reliable. Results. ICCs for relative Vo(2) (0.90), absolute Vo(2) (0.93), Vco(2) (0.93), and minute ventilation (0.95) demonstrated high reliability, but not for heart rate (0.76) or respiratory exchange ratio (0.64). There was no significant difference in the distance each participant walked between the first and second tests, eliminating distance as a potential confounder of our analyses (ICC = 0.99). Conclusions. Our results strongly support the reliability of the K4b(2) for quantifying overground gait efficiency after stroke. Use of this device may enable researchers to study how varying poststroke rehabilitation interventions affect this central measure of health and function.
引用
收藏
页码:872 / 877
页数:6
相关论文
共 50 条
  • [1] Test-retest reliability of a portable monitor to assess energy expenditure
    Brazeau, Anne-Sophie
    Karelis, Antony D.
    Mignault, Diane
    Lacroix, Marie-Josee
    Prud'homme, Denis
    Rabasa-Lhoret, Remi
    APPLIED PHYSIOLOGY NUTRITION AND METABOLISM-PHYSIOLOGIE APPLIQUEE NUTRITION ET METABOLISME, 2011, 36 (03): : 339 - 343
  • [2] Test-retest reliability of the GAITRite system in people with stroke undergoing rehabilitation
    Kuys, Suzanne S.
    Brauer, Sandra G.
    Ada, Louise
    DISABILITY AND REHABILITATION, 2011, 33 (19-20) : 1848 - 1853
  • [3] Validity and Test-Retest Reliability of a Thai Stroke Physical Activity Questionnaire
    Potchana, Kusuma
    Saengsuwan, Jittima
    Kittipanya-ngam, Pajeemas
    JOURNAL OF STROKE & CEREBROVASCULAR DISEASES, 2021, 30 (08)
  • [4] Reaching performance scale for stroke - Test-retest reliability, measurement error, concurrent and discriminant validity
    Subramanian, Sandeep K.
    Banina, Melanie C.
    Turolla, Andrea
    Levin, Mindy F.
    PM&R, 2022, 14 (03) : 337 - 347
  • [5] Test-retest reliability of isokinetic muscle strength of the lower extremities in patients with stroke
    Hsu, AL
    Tang, PF
    Jan, MH
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2002, 83 (08): : 1130 - 1137
  • [6] Test-Retest Reliability of the Neuromuscular Recovery Scale
    Behrman, Andrea L.
    Velozo, Craig
    Suter, Sarah
    Lorenz, Doug
    Basso, D. Michele
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2015, 96 (08): : 1375 - 1384
  • [7] Examination of the Test-Retest Reliability of a Computerized Neurocognitive Test Battery
    Nakayama, Yusuke
    Covassin, Tracey
    Schatz, Philip
    Nogle, Sally
    Kovan, Jeff
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2014, 42 (08) : 2000 - 2005
  • [8] Test-retest reliability and measurement error of the modified gait efficacy scale in individuals with stroke
    Avelino, Patrick R.
    Nascimento, Lucas R.
    Menezes, Kenia K. P.
    Alvarenga, Maria Tereza Mota
    Faria Fortini, Iza
    Teixeira-Salmela, Luci F.
    PHYSIOTHERAPY THEORY AND PRACTICE, 2022, 38 (13) : 2956 - 2961
  • [9] Concurrent Validity and Test-Retest Reliability of the 3-Meter Backward Walk Test in Stroke Survivors
    Kapan, Ali
    Ristic, Milos
    Yang, Lin
    Kranz, Gottfried
    Waldhoer, Thomas
    HEALTHCARE, 2023, 11 (23)
  • [10] Scapulohumeral control after stroke: A preliminary study of the test-retest reliability and discriminative validity of a clinical scapular protocol (ClinScaP)
    De Baets, Liesbet
    Jaspers, Ellen
    Van Deun, Sara
    NEUROREHABILITATION, 2016, 38 (04) : 359 - 370