Results of a Hydroxyapatite-Coated Modular Femoral Stem in Primary Total Hip Arthroplasty. A Minimum 5-Year Follow-Up

被引:10
|
作者
Garcia-Rey, Eduardo [1 ]
Munoz, Teresa [1 ]
Montejo, Jorge [1 ]
Martinez, Javier [1 ]
机构
[1] Fdn Hosp Alcorcon, Madrid, Spain
关键词
primary total hip arthroplasty; femoral stein; hydroxyapatite;
D O I
10.1016/j.arth.2007.10.012
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The use of a modular metaphyseal-diaphyseal femoral stem in primary total hip arthroplasty is infrequent. We analyze 94 ESOP (Fournitures Hospitalieres, Heinisbrunn, France) cementless 2-piece modular steins after a minimum 5 years of follow-up. There were 2 aseptic femoral stem loosenings and no cases with thigh pain. Mean femoral canal filling was 90%. Radiographic ingrowth was obtained in 83 (P < .001). At 7 years, the survival rate for femoral aseptic loosening was 97.8% and no stern was at risk for revision (95% confidence interval, 94.8%-100%). This prosthesis provides good clinical results with absence of pain and excellent. radiographic results. It is an option in femora with good bone quality. Femoral osteopenia and cortical widening were infrequent, and the modular metaphyseal-diaphyseal junction was not a problem in vivo.
引用
收藏
页码:1132 / 1139
页数:8
相关论文
共 50 条
  • [1] High Failure at a Minimum 5-Year Follow-Up in Primary Total Hip Arthroplasty Using a Modular Femoral Trunnion
    Nahhas, Cindy R.
    Yi, Paul H.
    Moric, Mario
    Puri, Rajeev
    Jacobs, Joshua J.
    Sporer, Scott M.
    JOURNAL OF ARTHROPLASTY, 2019, 34 (07) : 1395 - 1399
  • [2] A Randomized Trial of Hydroxyapatite-Coated Femoral Stems in Total Hip Arthroplasty A 13-Year Follow-Up
    Camazzola, Dan
    Hammond, Terry
    Gandhi, Rajiv
    Davey, J. Roderick
    JOURNAL OF ARTHROPLASTY, 2009, 24 (01) : 33 - 37
  • [3] Seven-year Results of a Tapered, Titanium, Hydroxyapatite-Coated Cementless Femoral Stem in Primary Total Hip Arthroplasty
    Cho, Jin-Ho
    Garino, Jonathan P.
    Choo, Suk-Kyu
    Han, Kye-Young
    Kim, Jung-Hoon
    Oh, Hyoung-Keun
    CLINICS IN ORTHOPEDIC SURGERY, 2010, 2 (04) : 214 - 220
  • [4] Simultaneous Bilateral Total Hip Arthroplasty With Hydroxyapatite-Coated Implants: A 20-Year Follow-Up
    Schwarzkopf, Ran
    Olivieri, Patrick
    Jaffe, William L.
    JOURNAL OF ARTHROPLASTY, 2012, 27 (07) : 1364 - 1369
  • [5] Comparison of Hydroxyapatite-Coated Stems in Total Hip Arthroplasty after a Minimum 10-Years Follow-up
    Gallo, J.
    Landor, I.
    Cechova, I.
    Jahoda, D.
    ACTA CHIRURGIAE ORTHOPAEDICAE ET TRAUMATOLOGIAE CECHOSLOVACA, 2008, 75 (05) : 339 - 346
  • [6] The use of a hydroxyapatite-coated primary stem in revision total hip arthroplasty
    Kelly, SJ
    Incavo, SJ
    Beynnon, B
    JOURNAL OF ARTHROPLASTY, 2006, 21 (01) : 64 - 71
  • [7] Revision of total hip arthroplasty by long locking stem with fully hydroxyapatite-coated modular metaphysis (Reef™): A continuous series of 78 cases at a minimum 2-year follow-up
    de Leissegues, Tristan
    Viste, Anthony
    Fessy, Michel-Henri
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2024, 110 (02)
  • [8] Hydroxyapatite-coated tapered cementless femoral components in total hip arthroplasty
    Chambers, Bryan
    St Clair, Selvon F.
    Froimson, Mark I.
    JOURNAL OF ARTHROPLASTY, 2007, 22 (04) : 71 - 74
  • [9] Grit-blasted and hydroxyapatite-coated total hip arthroplasty: an 11-to 14-year follow-up study
    Miyakawa, S
    Kawamura, H
    Mishima, H
    Yasumoto, J
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2004, 9 (05) : 462 - 467
  • [10] Hydroxyapatite-Coated Femoral Stems in Primary Total Hip Arthroplasty: An Updated Meta-Analysis
    Kim, William T.
    Woodruff, Robert
    Kalore, Niraj V.
    Vallem, Madan M.
    Cyrus, John W.
    Krumme, John W.
    Patel, Nirav K.
    Golladay, Gregory J.
    JOURNAL OF ARTHROPLASTY, 2024, 39 (03) : 846 - 850.e2