Effect of Thin Femtosecond LASIK Flaps on Corneal Sensitivity and Tear Function

被引:34
作者
Barequet, Irina S. [1 ,2 ]
Hirsh, Ami [2 ]
Levinger, Samuel [3 ]
机构
[1] Tel Aviv Univ, Chaim Sheba Med Ctr, Goldschleger Eye Inst, Sackler Fac Med, IL-52621 Tel Hashomer, Israel
[2] Enaim Refract Surg Ctr, Tel Aviv, Israel
[3] Enaim Refract Surg Ctr, Jerusalem, Israel
关键词
D O I
10.3928/1081597X-20081101-08
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To evaluate changes in corneal sensitivity and tear function following myopic LASIK with thin femtosecond flaps. METHODS: A retrospective study was performed to compare corneal sensitivity (filament), tear breakup time, and anesthetized Schirmer test preoperatively and at 1 week and 2 and 6 months postoperatively. RESULTS: Seventy-two eyes of 38 consecutive patients (20 women and 18 men) who underwent LASIK for myopia or myopic astigmatism with thin femtosecond flaps (IntraLase femtosecond laser system and Technolas 217 PlanoScan V2.9992 or wavefront-guided Zyoptix 3.1 excimer laser) were evaluated. Preoperative mean corneal sensitivity was 5.3 +/- 1.5 mm, which decreased to 4.6 +/- 1.7 mm at 1 week, increased to 5.0 +/- 1.3 mm at 2 months, and returned to baseline values at 6 months postoperatively. Mean Schirmer score was 13.7 +/- 5.7 mm preoperatively and 12.1 +/- 5.1, 13.1 +/- 4.8, and 13.0 +/- 5.1 mm at 1 week and 2 and 6 months postoperatively, respectively. Mean tear breakup time was 7.7 +/- 2.6 seconds preoperatively and 7.8 +/- 3.5, 9.2 +/- 4.6, and 8.8 +/- 4.5 seconds at week and 2 and 6 months postoperatively, respectively, No significant increase in fluorescein staining was observed throughout follow-up. CONCLUSIONS: Reductions in corneal sensitivity and tear function tests were minimal after myopic LASIK with thin femtosecond flaps. Despite the relatively narrow hinge, the thin, uniform femtosecond flap does not appear to have an adverse effect on corneal sensitivity and. dry eye signs at 6 months postoperatively, [J Refract Surg., 2008;24:897-902.]
引用
收藏
页码:897 / 902
页数:6
相关论文
共 27 条
[1]   Effect of laser in situ keratomileusis for hyperopia on tear film and ocular surface [J].
Albietz, JM ;
Lenton, LM ;
McLennan, SG .
JOURNAL OF REFRACTIVE SURGERY, 2002, 18 (02) :113-123
[2]   Effects of laser in situ keratomileusis on tear production, clearance, and the ocular surface [J].
Battat, L ;
Macri, A ;
Dursun, D ;
Pflugfelder, SC .
OPHTHALMOLOGY, 2001, 108 (07) :1230-1235
[3]   Decrease in tear secretion and corneal sensitivity after laser in situ keratomileusis [J].
Benitez-del-Castillo, JM ;
del Rio, T ;
Iradier, T ;
Hernández, JL ;
Castillo, A ;
Garcia-Sanchez, J .
CORNEA, 2001, 20 (01) :30-32
[4]   One thousand consecutive IntraLase laser in situ keratomileusis flaps [J].
Binder, Perry S. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (06) :962-969
[5]   Flap dimensions created with the IntraLase FS laser [J].
Binder, PS .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (01) :26-32
[6]   Corneal sensation after laser in situ keratomileusis [J].
Chuck, RS ;
Quiros, PA ;
Perez, AC ;
McDonnell, PJ .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2000, 26 (03) :337-339
[7]   The incidence and risk factors for developing dry eye after myopic LASIK [J].
De Paiva, CS ;
Chen, Z ;
Koch, DD ;
Hamill, MB ;
Manuel, FK ;
Hassan, SS ;
Wilhelmus, KR ;
Pflugfelder, SC .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2006, 141 (03) :438-445
[8]   The effect of hinge position on corneal sensation and dry eye after LASIK [J].
Donnenfeld, ED ;
Solomon, K ;
Perry, HD ;
Doshi, SJ ;
Ehrenhaus, M ;
Solomon, R ;
Biser, S .
OPHTHALMOLOGY, 2003, 110 (05) :1023-1029
[9]   Femtosecond laser versus mechanical keratome flaps in wavefront-guided laser in situ keratomileusis - Prospective contralateral eye study [J].
Durrie, DS ;
Kezirian, GA .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (01) :120-126
[10]   Comparison of corneal sensation following photorefractive keratectomy and laser in situ keratomileusis [J].
Kanellopoulos, AJ ;
Pallikaris, IG ;
Donnenfeld, ED ;
Detorakis, S ;
Koufala, K ;
Perry, HD .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1997, 23 (01) :34-38