Adhesive Strength of Fibrinogen-Coated Collagen Patch or Liquid Fibrin Sealant in an Experimental Liver Resection Model in Pigs

被引:30
作者
Erdogan, D. [1 ]
de Graaf, W. [1 ]
van Gulik, T. M. [1 ]
机构
[1] Univ Amsterdam, Acad Med Ctr, Dept Surg, Surg Lab, NL-1105 AZ Amsterdam, Netherlands
关键词
Fibrinogen-coated collagen patch; Fibrin glue; Liver resection; Adhesive strength;
D O I
10.1159/000155879
中图分类号
R61 [外科手术学];
学科分类号
摘要
Aim: The aim of this study was to assess the efficacy of sealing bile ducts by determining the adhesive strength of 2 different sealing agents, i.e. a fibrinogen-coated collagen patch (TachoSil (R)) and a liquid fibrin sealant (Tissucol (R)), in an experimental partial liver resection model in pigs. Methods: Pigs underwent laparotomy and partial resection of the left medial liver lobe. A 16-Ch silicon catheter was introduced into the common bile duct. Pigs were randomly assigned to 2 groups (n = 4 each). In group 1, TachoSil was applied on the resection surface, and in group 2 Tissucol was applied. After 2 h, pressure in the intrabiliary system was gradually increased. Results: No significant differences in the hemostasis times between TachoSil and Tissucol were observed (210.0 +/- 12.9 vs. 208.8 +/- 14.2 s; p = 0.9506). The pressure that could be resisted with Tissucol was significantly lower compared to TachoSil (77.0 +/- 8.6 vs. 131.8 +/- 16.3 mm Hg; p = 0.0405). Conclusions: The application of TachoSil on the resection surface is equally effective in obtaining hemostasis and in sealing of biliary ducts as Tissucol. The adhesive strength of TachoSil on the resection surface, however, is superior to Tissucol. Copyright (C) 2008 S. Karger AG, Basel
引用
收藏
页码:298 / 302
页数:5
相关论文
共 11 条
[1]   Seven hundred forty-seven hepatectomies in the 1990s: An update to evaluate the actual risk of liver resection [J].
Belghiti, J ;
Hiramatsu, K ;
Benoist, S ;
Massault, PP ;
Sauvanet, A ;
Farges, O .
JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 2000, 191 (01) :38-46
[2]   Evaluating the in vitro adhesive strength of biomaterials. Biosimulator for selective leak closure [J].
Carbon, RT ;
Baar, S ;
Kriegelstein, S ;
Huemmer, HP ;
Baar, K ;
Simon, SI .
BIOMATERIALS, 2003, 24 (08) :1469-1475
[3]  
COUTO J, 1987, SURGERY, V101, P354
[4]   Structural and mechanical remodelling of the common bile duct after obstruction [J].
Duch, BU ;
Andersen, HL ;
Smith, J ;
Kassab, GS ;
Gregersen, H .
NEUROGASTROENTEROLOGY AND MOTILITY, 2002, 14 (02) :111-122
[5]   Incidence and management of bile leakage after partial liver resection [J].
Erdogan, D. ;
Busch, O. R. C. ;
Van Delden, O. M. ;
Rauws, E. A. J. ;
Gouma, D. J. ;
Van Gulik, T. M. .
DIGESTIVE SURGERY, 2008, 25 (01) :60-66
[6]   Prevention of biliary leakage after partial liver resection using topical hemostatic agents [J].
Erdogan, Deha ;
Busch, Olivier R. C. ;
Gouma, Dirk J. ;
van Gulik, Thomas M. .
DIGESTIVE SURGERY, 2007, 24 (04) :294-299
[7]   Effectiveness of a new carrier-bound fibrin sealant versus argon beamer as haemostatic agent during liver resection:: a randomised prospective trial [J].
Frilling, A ;
Stavrou, GA ;
Mischinger, HJ ;
de Hemptinne, B ;
Rokkjaer, M ;
Klempnauer, J ;
Thörne, A ;
Gloor, B ;
Beckebaum, S ;
Ghaffar, MFA ;
Broelsch, CE .
LANGENBECKS ARCHIVES OF SURGERY, 2005, 390 (02) :114-120
[8]  
JONES DB, 1995, SURG ENDOSC-ULTRAS, V9, P1020
[9]  
KRAM HB, 1985, ARCH SURG-CHICAGO, V120, P1250
[10]  
Sierra D H, 1993, J Biomater Appl, V7, P309, DOI 10.1177/088532829300700402