摘要
This study was designed to determine the magnitude and spatial distribution of temperature elevations when using 480 kHz RF and 2.45 GHz microwave energy in ex vivo liver models. A total of 60 heating cycles (20 s at 90 W) were performed in normal, RF-ablated, and microwave-ablated liver tissues (n = 10 RF and n = 10 microwave in each tissue type). Heating cycles were performed using a 480-kHz generator and 3-cm cooled-tip electrode (RF) or a 2.45-GHz generator and 14-gauge monopole (microwave) and were designed to isolate direct heating from each energy type. Tissue temperatures were measured by using fiberoptic thermosensors 5, 10, and 15 mm radially from the ablation applicator at the depth of maximal heating. Power delivered, sensor location, heating rates, and maximal temperatures were compared using mixed effects regression models. No significant differences were noted in mean power delivered or thermosensor locations between RF and microwave heating groups (P > 0.05). Microwaves produced significantly more rapid heating than RF at 5, 10, and 15 mm in normal tissue (3.0 vs. 0.73, 0.85 vs. 0.21, and 0.17 vs. 0.09 A degrees C/s; P < 0.05); and at 5 and 10 mm in ablated tissues (2.3 +/- A 1.4 vs. 0.7 +/- A 0.3, 0.5 +/- A 0.3 vs. 0.2 +/- A 0 A degrees C/s, P < 0.05). The radial depth of heating was similar to 5 mm greater for microwaves than RF. Direct heating obtained with 2.45-GHz microwave energy using a single needle-like applicator is faster and covers a larger volume of tissue than 480-kHz RF energy.
引用
收藏
页码:505 / 511
页数:7
相关论文
共 50 条
  • [41] Radiofrequency Ablation with an Internally Cooled Monopolar Directional Electrode: Ex Vivo and in Vivo Experimental Studies in the Liver
    Yu, Mi Hye
    Lee, Jae Young
    Jun, Su Ryoung
    Kim, Kyung Won
    Kim, Se Hyung
    Han, Joon Koo
    Choi, Byung Ihn
    RADIOLOGY, 2016, 278 (02) : 395 - 404
  • [42] Bipolar radiofrequency ablation with 2 x 2 electrodes as a building block for matrix radiofrequency ablation: Ex vivo liver experiments and finite element method modelling
    Mulier, Stefaan
    Jiang, Yansheng
    Jamart, Jacques
    Wang, Chong
    Feng, Yuanbo
    Marchal, Guy
    Michel, Luc
    Ni, Yicheng
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2015, 31 (06) : 649 - 665
  • [43] Comparative Study of Ablation Zone of EMPRINT HP Microwave Device with Contemporary 2.4 GHz Microwave Devices in an Ex Vivo Porcine Liver Model
    Hui, Terrence C. H.
    How, Guo Yuan
    Chim, Michelle S. M.
    Pua, Uei
    DIAGNOSTICS, 2023, 13 (16)
  • [44] Three-dimensional temperature map during microwave ablation of ex vivo porcine liver: theoretical prediction and experimental validation
    Schena, Emiliano
    Villani, Serena
    Massaroni, Carlo
    Fong, Yuman
    Saccomandi, Paola
    Diana, Michele
    Marescaux, Jacques
    2016 NANOTECHNOLOGY FOR INSTRUMENTATION AND MEASUREMENT (NANOFIM), 2016,
  • [45] Monitoring Thermal Ablation via Microwave Tomography: An Ex Vivo Experimental Assessment
    Scapaticci, Rosa
    Lopresto, Vanni
    Pinto, Rosanna
    Cavagnaro, Marta
    Crocco, Lorenzo
    DIAGNOSTICS, 2018, 8 (04):
  • [46] Influence of interapplicator distance on multibipolar radiofrequency ablation during physiological and interrupted liver perfusion in an in vivo porcine model
    Poch, F. G. M.
    Neizert, C. A.
    Geyer, B.
    Gemeinhardt, O.
    Bruder, L.
    Niehues, S. M.
    Vahldiek, J. L.
    Bressem, K. K.
    Kreis, M. E.
    Lehmann, K. S.
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [47] Stiffness distribution in the ablated zone after radiofrequency ablation for liver: An ex-vivo study with a tissue elastometer
    Guo, Le-Hang
    Wang, Dan
    Li, Xiao-Long
    Liu, Bo-Ji
    Chen, Shigao
    Li, Dan-Dan
    Xu, Hui-Xiong
    CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2019, 72 (02) : 151 - 160
  • [48] Radiofrequency ablation lesion detection using MR-based electrical conductivity imaging: A feasibility study of ex vivo liver experiments
    Chauhan, Munish
    Jeong, Woo Chul
    Kim, Hyung Joong
    Kwon, Oh In
    Woo, Eung Je
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2013, 29 (07) : 643 - 652
  • [49] Ultrasound-guided ablation of malignant liver tumors: Radiofrequency and microwave ablation
    Kasten P.
    Potthoff A.
    Der Gastroenterologe, 2018, 13 (4): : 284 - 291
  • [50] Evaluation method of ex vivo porcine liver reduced scattering coefficient during microwave ablation based on temperature
    Jin, Xiaofei
    Liu, Wenwen
    Li, Yiran
    Qian, Lu
    Zhu, Qiaoqiao
    Li, Weitao
    Qian, Zhiyu
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2022, 67 (06): : 491 - 501