Spinal manipulation force and duration affect vertebral movement and neuromuscular responses

被引:66
作者
Colloca, CJ
Keller, TS
Harrison, DE
Moore, RJ
Gunzburg, R
Harrison, DD
机构
[1] Arizona State Univ, Biomechan Labs, Exercise & Sport Res Inst, Dept Kinesiol, Tempe, AZ USA
[2] Univ Vermont, Dept Mech Engn, Burlington, VT USA
[3] Univ Vermont, Dept Orthopaed & Rehabil, Burlington, VT USA
[4] Chiropract Biophys Non Profit Inc, Evanston, WY USA
[5] Adelaide Ctr Spinal Res, Inst Med & Vet Sci, Adelaide, SA, Australia
[6] Eeuwfeestklin Hosp, Dept Orthopaed Surg, Antwerp, Belgium
关键词
biomechanics; dynamic loading; electromyography; lumbar spine; spinal manipulation;
D O I
10.1016/j.clinbiomech.2005.10.006
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background. Previous study in human subjects has documented biomechanical and neurophysiological responses to impulsive spinal manipulative thrusts, but very little is known about the neuromechanical effects of varying thrust force-time profiles. Methods. Ten adolescent Merino sheep were anesthetized and posteroanterior mechanical thrusts were applied to the L3 spinous process using a computer-controlled, mechanical testing apparatus. Three variable pulse durations (10, 100, 200 ms, force = 80 N) and three variable force amplitudes (20, 40, 60 N, pulse duration = 100 ms) were examined for their effect on lumbar motion response (L3 displacement, L1, L2 acceleration) and normalized multifidus electromyographic response (L3, L4) using a repeated measures analysis of variance. Findings. Increasing L3 posteroanterior force amplitude resulted in a fourfold linear increase in L3 posteroanterior vertebral displacement (p < 0.001) and adjacent segment (L1, L2) posteroanterior acceleration response (p < 0.001). L3 displacement was linearly correlated (p < 0.001) to the acceleration response over the 20-80 N force range (100 ins). At constant force, 10 ms thrusts resulted in nearly fivefold lower L3 displacements and significantly increased segmental (L2) acceleration responses compared to the 100 ms (19%, p = 0.005) and 200 ms (16%, p = 0.023) thrusts. Normalized electromyographic responses increased linearly with increasing force amplitude at higher amplitudes and were appreciably affected by mechanical excitation pulse duration. Interpretation. Changes in the biomechanical and neuromuscular response of the ovine lumbar spine were observed in response to changes in the force-time characteristics of the spinal manipulative thrusts and may be an underlying mechanism in related clinical outcomes. (C) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:254 / 262
页数:9
相关论文
共 33 条
[1]  
Bronfort Gert, 2004, Spine J, V4, P335, DOI 10.1016/j.spinee.2003.06.002
[2]   Neurophysiologic response to intraoperative lumbosacral spinal manipulation [J].
Colloca, CJ ;
Keller, TS ;
Gunzburg, R ;
Vandeputte, K ;
Fuhr, AW .
JOURNAL OF MANIPULATIVE AND PHYSIOLOGICAL THERAPEUTICS, 2000, 23 (07) :447-457
[3]   Biomechanical and neurophysiological responses to spinal manipulation in patients with lumbar radiculopathy [J].
Colloca, CJ ;
Keller, TS ;
Gunzburg, R .
JOURNAL OF MANIPULATIVE AND PHYSIOLOGICAL THERAPEUTICS, 2004, 27 (01) :1-15
[4]   Neuromechanical characterization of in vivo lumbar spinal manipulation. Part II. Neurophysiological response [J].
Colloca, CJ ;
Keller, TS ;
Gunzburg, R .
JOURNAL OF MANIPULATIVE AND PHYSIOLOGICAL THERAPEUTICS, 2003, 26 (09) :579-591
[5]   Electromyographic reflex responses to mechanical force, manually assisted spinal manipulative therapy [J].
Colloca, CJ ;
Keller, TS .
SPINE, 2001, 26 (10) :1117-1124
[6]  
Gál J, 1997, J MANIP PHYSIOL THER, V20, P30
[7]   Measurements of vertebral translations using bone pins, surface markers and accelerometers [J].
Gal, J ;
Herzog, W ;
Kawchuk, G ;
Conway, P ;
Zhang, YT .
CLINICAL BIOMECHANICS, 1997, 12 (05) :337-340
[8]  
GAL JM, 1995, J MANIP PHYSIOL THER, V18, P4
[9]  
GEMMELL HA, 1995, J MANIP PHYSIOL THER, V18, P453
[10]   Electromyographic responses of back and limb muscles associated with spinal manipulative therapy [J].
Herzog, W ;
Scheele, D ;
Conway, PJ .
SPINE, 1999, 24 (02) :146-152