Using overlap volume histogram and IMRT plan data to guide and automate VMAT planning: A head-and-neck case study

被引:83
作者
Wu, Binbin [1 ]
Pang, Dalong [1 ]
Simari, Patricio [2 ]
Taylor, Russell [3 ]
Sanguineti, Giuseppe [4 ]
McNutt, Todd [4 ]
机构
[1] Georgetown Univ Hosp, Dept Radiat Med, Washington, DC 20007 USA
[2] Univ Maryland, Dept Comp Sci, College Pk, MD 20740 USA
[3] Johns Hopkins Univ, Whiting Sch Engn, Dept Comp Sci, Baltimore, MD 21218 USA
[4] Johns Hopkins Univ, Dept Radiat Oncol & Mol Radiat Sci, Baltimore, MD 21231 USA
关键词
VMAT; OVH; IMRT database; DVH; head-and-neck; MODULATED ARC THERAPY; RADIATION-THERAPY; CANCER; QUALITY; RADIOTHERAPY; IMPACT;
D O I
10.1118/1.4788671
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To investigate whether an overlap volume histogram (OVH)-driven planning application using an intensity-modulated radiation therapy (IMRT) database can guide and automate volumetric-modulated arc therapy (VMAT) planning for head-and-neck cancer. Methods: Based on comparable head-and-neck dosimetric results between planner-generated VMAT and IMRT plans, an inhouse developed, OVH-driven automated planning application containing a database of prior clinical head-and-neck IMRT plans is built into Pinnacle(3) SmartArc for VMAT planning. Double-arc VMAT plans of four oropharynx, four nasopharynx, and four larynx patients are generated and compared with corresponding clinical IMRT plans. Results: Each VMAT plan is automatically generated in two optimization rounds, while the average number of optimization rounds in generating a clinical IMRT plan is 43. In VMAT plans, statistical superiority (p < 0.01) in sparing of the cord+4 mm, brainstem, brachial plexus, larynx, and inner ear is observed with a slight degradation in low-dose-level planning target volume (PTV) coverage. On average, D-0.1 cc to the cord+4 mm, brainstem and brachial plexus is reduced by 3.7, 4.9, and 1.6 Gy, respectively; V(50 Gy) to the larynx is reduced by 5.3%; mean dose to the inner ear is reduced by 4.4 Gy; V-95 of low-dose-level PTV coverage is reduced by 0.3% with p = 0.25. Conclusions: IMRT-data-driven VMAT planning offers a potential method for generating VMAT plans that are comparable to IMRT plans in terms of dosimetric quality. (c) 2013 American Association of Physicists in Medicine. [http://dx.doi.org/10.1118/1.4788671]
引用
收藏
页数:7
相关论文
共 25 条
[1]   Single Arc Volumetric Modulated Arc Therapy of head and neck cancer [J].
Bertelsen, Anders ;
Hansen, Christian R. ;
Johansen, Jorgen ;
Brink, Carsten .
RADIOTHERAPY AND ONCOLOGY, 2010, 95 (02) :142-148
[2]   Development and evaluation of an efficient approach to volumetric arc therapy planning [J].
Bzdusek, Karl ;
Friberger, Henrik ;
Eriksson, Kjell ;
Hardemark, Bjorn ;
Robinson, David ;
Kaus, Michael .
MEDICAL PHYSICS, 2009, 36 (06) :2328-2339
[3]   Impact of leaf motion constraints on IMAT plan quality, deliver accuracy, and efficiency [J].
Chen, Fan ;
Rao, Min ;
Ye, Jin-song ;
Shepard, David M. ;
Cao, Daliang .
MEDICAL PHYSICS, 2011, 38 (11) :6106-6118
[4]   SMARTARC-BASED VOLUMETRIC MODULATED ARC THERAPY FOR OROPHARYNGEAL CANCER: A DOSIMETRIC COMPARISON WITH BOTH INTENSITY-MODULATED RADIATION THERAPY AND HELICAL TOMOTHERAPY [J].
Clemente, Stefania ;
Wu, BinBin ;
Sanguineti, Giuseppe ;
Fusco, Vincenzo ;
Ricchetti, Francesco ;
Wong, John ;
McNutt, Todd .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 80 (04) :1248-1255
[5]   Multicriteria VMAT optimization [J].
Craft, David ;
McQuaid, Dualta ;
Wala, Jeremiah ;
Chen, Wei ;
Salari, Ehsan ;
Bortfeld, Thomas .
MEDICAL PHYSICS, 2012, 39 (02) :686-696
[6]   Plan space: Representation of treatment plans in multidimensional space [J].
Gopal, R ;
Starkschall, G .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 53 (05) :1328-1336
[7]   Is a single arc sufficient in volumetric-modulated arc therapy (VMAT) for complex-shaped target volumes? [J].
Guckenberger, Matthias ;
Richter, Anne ;
Krieger, Thomas ;
Wilbert, Juergen ;
Baier, Kurt ;
Flentje, Michael .
RADIOTHERAPY AND ONCOLOGY, 2009, 93 (02) :259-265
[8]  
Hardemark B., 2003, Direct machine parameter optimization with RayMachine in Pinnacle
[9]   Geometric factors influencing dosimetric sparing of the parotid glands using IMRT [J].
Hunt, Margie A. ;
Jackson, Andrew ;
Narayana, Ashwatha ;
Lee, Nancy .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (01) :296-304
[10]   Treatment Planning and Delivery Evaluation of Volumetric Modulated Arc Therapy for Stereotactic Body Radiotherapy of Spinal Tumours: Impact of Arc Discretization in Planning System [J].
Marchand, E. L. ;
Sahgal, A. ;
Zhang, T. J. ;
Millar, B. A. ;
Sharpe, M. ;
Moseley, D. ;
Letourneau, D. .
TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2012, 11 (06) :599-606