Effects of different inter-implant distances on the stress distribution around endosseous implants in posterior mandible: A 3D finite element analysis

被引:61
|
作者
Simsek, B
Erkmen, E
Yilmaz, D
Eser, A
机构
[1] Gazi Univ, Fac Dent, Dept Oral & Maxillofacial Surg, TR-06690 Ankara, Turkey
[2] Middle E Tech Univ, Dept Mech Engn, Ankara, Turkey
关键词
inter-implant distance; dental implant; peri-implant structure; stress distribution; 3D finite elements analysis;
D O I
10.1016/j.medengphy.2005.04.025
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose: The aim of this study was to evaluate the effects of different inter-implant distances on stress distribution in the bone around the endosseous titanium implants under vertical, oblique and horizontal loads in the posterior mandibular edentulousim by finite element analysis (3D FEA). Materials and methods: 3D FEA models representing mandible and ITI (R) implant (Straumann, Waldenburg, Switzerland) were simulated. The distances in-between the units were set at 0.5, 1.0 and 2.0 cm. Vertical (V) 70 degrees N, 60 degrees oblique (BL) 35 degrees N in buccolingual direction and horizontal (MD) 14 degrees N in mesiodistal direction loads were applied to each of these designs. The principal stresses (tensile and compressive stress) on each model were calculated using MSC MARC finite element analyze solver software. Results: The tensile stress (P-max) values have been evaluated that they rose at the cervical region of buccal side when the inter-implant distances increased under V and BL loads and they diminished while the inter-implant distances decreased. In short inter-implant distances the compressive stress (P-min) has been presented with increased values and found at the lingual surface of the cervical region. Discussion: The results of this study indicated that the magnitude of the stress was influenced by complex factors such as the direction of loads and the distance between adjacent fixtures. The stress occurring around fixtures differs significantly with various types of inter-implant distance. Conclusion: The evaluation of tensile and compressive stresses for cortical and cancellous bone under V,(MD)-M-1 and BL loading conditions in aspect of inter-implant distance shows; the 1.0 cm of inter-implant distance is the optimum distance for two fixture implantation. (c) 2005 IPEM. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:199 / 213
页数:15
相关论文
共 50 条
  • [41] Experimental Evaluation and Finite Element Analysis of Stress Distribution in 3D-Printed Dental Implants to Validate the Optimal Thread Pitch
    Irudhayam, Jackson S.
    Venkatesan, Hariram
    REVUE DES COMPOSITES ET DES MATERIAUX AVANCES-JOURNAL OF COMPOSITE AND ADVANCED MATERIALS, 2024, 34 (02): : 257 - 267
  • [42] Transient Heat Transfer in Dental Implants for Thermal Necrosis-Aided Implant Removal: A 3D Finite Element Analysis
    Gungormus, Mustafa
    Erbasar, Guzin Neda Hasanoglu
    JOURNAL OF ORAL IMPLANTOLOGY, 2019, 45 (03) : 196 - 201
  • [43] Impact of implant diameter and length on stress distribution in osseointegrated implants: A 3D FEA study
    Eazhil, R.
    Swaminathan, Siva Vadivel
    Gunaseelan, Madhan
    Kannan, G. Vijay
    Alagesan, Chandrapandian
    JOURNAL OF INTERNATIONAL SOCIETY OF PREVENTIVE AND COMMUNITY DENTISTRY, 2016, 6 (06): : 590 - 596
  • [44] Bone Stress Analysis of Various Angulations of Mesiodistal Implants with Splinted Crowns in the Posterior Mandible: A Three-Dimensional Finite Element Study
    Lan, Ting-Hsun
    Pan, Chin-Yun
    Lee, Huey-Er
    Huang, Heng-Li
    Wang, Chau-Hsiang
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2010, 25 (04) : 763 - 770
  • [45] Effects of post materials and length on the stress distribution of endodontically treated maxillary central incisors: a 3D finite element analysis
    Hsu, M. -L.
    Chen, C. -S.
    Chen, B. -J.
    Huang, H. -H.
    Chang, C. -L.
    JOURNAL OF ORAL REHABILITATION, 2009, 36 (11) : 821 - 830
  • [46] Effect of attachment types and number of implants supporting mandibular overdentures on stress distribution: A computed tomography-based 3D finite element analysis
    Bilhan, Selda Arat
    Baykasoglu, Cengiz
    Bilhan, Hakan
    Kutay, Omer
    Mugan, Ata
    JOURNAL OF BIOMECHANICS, 2015, 48 (01) : 130 - 137
  • [47] Quantitative and qualitative 3D analysis of mandibular lingual concavities: Implications for dental implant planning in the posterior mandible
    Alqutaibi, Ahmed Yaseen
    Alghauli, Mohammed Ahmed
    Aboalrejal, Afaf
    Mulla, Abduljabbar K.
    Almohammadi, Anwar A.
    Aljayyar, Abdullah W.
    Alharbi, Shahad O.
    Almuzaini, Esam S.
    Alsaeedi, Ahmed K.
    Arabi, Lina F.
    Alhajj, Mohammed Nasser
    Halboub, Esam
    CLINICAL AND EXPERIMENTAL DENTAL RESEARCH, 2024, 10 (01):
  • [48] Comparative evaluation of peri-implant stress distribution in implant protected occlusion and cuspally loaded occlusion on a 3 unit implant supported fixed partial denture: A 3D finite element analysis study
    Acharya, Paramba Hitendrabhai
    Patel, Vilas Valjibhai
    Duseja, Sareen Subhash
    Chauhan, Vishal Rajendrabhai
    JOURNAL OF ADVANCED PROSTHODONTICS, 2021, 13 (02): : 79 - 88
  • [49] The effect of implant neck microthread design on stress distribution of peri-implant bone with different level: A finite element analysis
    Jin, Zhi-Heng
    Peng, Meng-Dong
    Li, Qing
    JOURNAL OF DENTAL SCIENCES, 2020, 15 (04) : 466 - 471
  • [50] The Effect of Implant Length and Diameter on Stress Distribution around Single Implant Placement in 3D Posterior Mandibular FE Model Directly Constructed Form In Vivo CT
    Shinya, Akikazu
    Ishida, Yoshiki
    Miura, Daisuke
    Shinya, Akiyoshi
    MATERIALS, 2021, 14 (23)