Effects of different inter-implant distances on the stress distribution around endosseous implants in posterior mandible: A 3D finite element analysis

被引:61
|
作者
Simsek, B
Erkmen, E
Yilmaz, D
Eser, A
机构
[1] Gazi Univ, Fac Dent, Dept Oral & Maxillofacial Surg, TR-06690 Ankara, Turkey
[2] Middle E Tech Univ, Dept Mech Engn, Ankara, Turkey
关键词
inter-implant distance; dental implant; peri-implant structure; stress distribution; 3D finite elements analysis;
D O I
10.1016/j.medengphy.2005.04.025
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose: The aim of this study was to evaluate the effects of different inter-implant distances on stress distribution in the bone around the endosseous titanium implants under vertical, oblique and horizontal loads in the posterior mandibular edentulousim by finite element analysis (3D FEA). Materials and methods: 3D FEA models representing mandible and ITI (R) implant (Straumann, Waldenburg, Switzerland) were simulated. The distances in-between the units were set at 0.5, 1.0 and 2.0 cm. Vertical (V) 70 degrees N, 60 degrees oblique (BL) 35 degrees N in buccolingual direction and horizontal (MD) 14 degrees N in mesiodistal direction loads were applied to each of these designs. The principal stresses (tensile and compressive stress) on each model were calculated using MSC MARC finite element analyze solver software. Results: The tensile stress (P-max) values have been evaluated that they rose at the cervical region of buccal side when the inter-implant distances increased under V and BL loads and they diminished while the inter-implant distances decreased. In short inter-implant distances the compressive stress (P-min) has been presented with increased values and found at the lingual surface of the cervical region. Discussion: The results of this study indicated that the magnitude of the stress was influenced by complex factors such as the direction of loads and the distance between adjacent fixtures. The stress occurring around fixtures differs significantly with various types of inter-implant distance. Conclusion: The evaluation of tensile and compressive stresses for cortical and cancellous bone under V,(MD)-M-1 and BL loading conditions in aspect of inter-implant distance shows; the 1.0 cm of inter-implant distance is the optimum distance for two fixture implantation. (c) 2005 IPEM. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:199 / 213
页数:15
相关论文
共 50 条
  • [31] Comparison of finite element results with photoelastic stress analysis around dental implants with different threads
    Geramizadeh, Maryam
    Katoozian, Hamidreza
    Amid, Reza
    Kadkhodazadeh, Mahdi
    DENTAL AND MEDICAL PROBLEMS, 2018, 55 (01) : 17 - 21
  • [32] Finite Element Analysis of the Stress Distribution Associated With Different Implant Designs for Different Bone Densities
    Kurtulus, Ikbal Leblebicioglu
    Kilic, Kerem
    Bal, Burak
    Kilavuz, Ahmet
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2022, 31 (07): : 614 - 622
  • [33] The effect of frontal trauma on the edentulous mandible with four different interforaminal implant-prosthodontic anchoring configurations. A 3D finite element analysis
    Stefan, Krennmair
    Michael, Malek
    Raphael, Stehrer
    Staehler, Philip
    Sven, Otto
    Lukas, Postl
    EUROPEAN JOURNAL OF MEDICAL RESEARCH, 2023, 28 (01)
  • [34] Biomechanical Effects of Different Load Cases with an Implant-Supported Full Bridge on Four Implants in an Edentulous Mandible: A Three-Dimensional Finite Element Analysis (3D-FEA)
    Szabo, arpad Laszlo
    Matusovits, Danica
    Slyteen, Haydar
    Lakatos, eva Ilona
    Barath, Zoltan
    Schmidlin, Patrick R.
    DENTISTRY JOURNAL, 2023, 11 (11)
  • [35] Influence of different implant-abutment connections on stress distribution in single tilted implants and peripheral bone: A three-dimensional finite element analysis
    Ozturk, Ozgur
    Kulunk, Tolga
    Kulunk, Safak
    BIO-MEDICAL MATERIALS AND ENGINEERING, 2018, 29 (04) : 513 - 526
  • [36] Stress distribution and microgap formation in angulated zirconia abutments with a titanium base in narrow diameter implants: A 3D finite element analysis
    Zhang, Yuqiang
    Yu, Ping
    Yu, Haiyang
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2022, 38 (07)
  • [37] Effect of Integration Patterns Around Implant Neck on Stress Distribution in Peri-Implant Bone: A Finite Element Analysis
    Han, Jingyun
    Sun, Yuchun
    Wang, Chao
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2017, 26 (06): : 549 - 558
  • [38] Effect of Offset Implant Placement on the Stress Distribution Around a Dental Implant: A Three-Dimensional Finite Element Analysis
    Siadat, Hakimeh
    Hashemzadeh, Shervin
    Geramy, Allahyar
    Bassir, Seyed Hossein
    Alikhasi, Marzieh
    JOURNAL OF ORAL IMPLANTOLOGY, 2015, 41 (06) : 646 - 651
  • [39] Variation in stress distribution modified by mandibular material property: a 3D finite element analysis
    Zheng, Fangjie
    Zhu, Yunfan
    Gong, Yanji
    Yin, Deqiang
    Liu, Yang
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2023, 229
  • [40] EFFECTS OF DENTAL IMPLANT LENGTH AND BONE QUALITY ON BIOMECHANICAL RESPONSES IN BONE AROUND IMPLANTS: A 3-D NON-LINEAR FINITE ELEMENT ANALYSIS
    Lin, Chun-Li
    Kuo, Yu-Chan
    Lin, Ting-Sheng
    BIOMEDICAL ENGINEERING-APPLICATIONS BASIS COMMUNICATIONS, 2005, 17 (01): : 44 - 49