Effects of different inter-implant distances on the stress distribution around endosseous implants in posterior mandible: A 3D finite element analysis

被引:61
|
作者
Simsek, B
Erkmen, E
Yilmaz, D
Eser, A
机构
[1] Gazi Univ, Fac Dent, Dept Oral & Maxillofacial Surg, TR-06690 Ankara, Turkey
[2] Middle E Tech Univ, Dept Mech Engn, Ankara, Turkey
关键词
inter-implant distance; dental implant; peri-implant structure; stress distribution; 3D finite elements analysis;
D O I
10.1016/j.medengphy.2005.04.025
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose: The aim of this study was to evaluate the effects of different inter-implant distances on stress distribution in the bone around the endosseous titanium implants under vertical, oblique and horizontal loads in the posterior mandibular edentulousim by finite element analysis (3D FEA). Materials and methods: 3D FEA models representing mandible and ITI (R) implant (Straumann, Waldenburg, Switzerland) were simulated. The distances in-between the units were set at 0.5, 1.0 and 2.0 cm. Vertical (V) 70 degrees N, 60 degrees oblique (BL) 35 degrees N in buccolingual direction and horizontal (MD) 14 degrees N in mesiodistal direction loads were applied to each of these designs. The principal stresses (tensile and compressive stress) on each model were calculated using MSC MARC finite element analyze solver software. Results: The tensile stress (P-max) values have been evaluated that they rose at the cervical region of buccal side when the inter-implant distances increased under V and BL loads and they diminished while the inter-implant distances decreased. In short inter-implant distances the compressive stress (P-min) has been presented with increased values and found at the lingual surface of the cervical region. Discussion: The results of this study indicated that the magnitude of the stress was influenced by complex factors such as the direction of loads and the distance between adjacent fixtures. The stress occurring around fixtures differs significantly with various types of inter-implant distance. Conclusion: The evaluation of tensile and compressive stresses for cortical and cancellous bone under V,(MD)-M-1 and BL loading conditions in aspect of inter-implant distance shows; the 1.0 cm of inter-implant distance is the optimum distance for two fixture implantation. (c) 2005 IPEM. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:199 / 213
页数:15
相关论文
共 50 条
  • [21] Comparison of stress distribution in dental crown with different cusp angles: 3D finite element analysis
    Kim, Han-Wool
    Choi, Byung-Ho
    Bae, Eun-Jeong
    Lim, Joong-Yeon
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2019, 22 (03) : 251 - 258
  • [22] Mechanical Influence of Edentulous Mandible Morphology on Peri-implant Bone in Implant Prosthetics: 3D Finite Element Analysis
    Hamada, Takumi
    Gonda, Tomoya
    Murase, Kohei
    Maeda, Yoshinobu
    Ikebe, Kazunori
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2024, 39 (06) : 931 - 937
  • [23] A 3D Finite Element Analysis Of Dental Implants With Varying Thread Angles
    NarendraKumar, U.
    Mathew, Arun Tom
    Iyer, Nikhil
    Rahman, Febin
    Manjubala, I.
    MATERIALS TODAY-PROCEEDINGS, 2018, 5 (05) : 11900 - 11905
  • [24] Splinting Effect on Posterior Implants Under Various Loading Modes: A 3D Finite Element Analysis
    Hauchard, Erwan
    Fournier, Benjamin Philippe
    Jacq, Romain
    Bouton, Antoine
    Pierrisnard, Laurent
    Naveau, Adrien
    EUROPEAN JOURNAL OF PROSTHODONTICS AND RESTORATIVE DENTISTRY, 2011, 19 (03): : 117 - 122
  • [25] Effect of angled abutments in the posterior maxillary region on tilted implants: a 3D finite element analysis
    Chen, Peng
    Zhang, Jianguo
    Yao, Juan
    Hu, Fengling
    Song, Liang
    Yu, Youcheng
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2024, 62 (08) : 2585 - 2597
  • [26] Investigation on Effects of Geometric Design Variable and Biomaterial Analysis on Stress Distribution for One-Piece Dental Implant - A 3D Finite Element Analysis
    Irudhayam, S. Jackson
    Venkatesan, Hariram
    ANNALES DE CHIMIE-SCIENCE DES MATERIAUX, 2024, 48 (03): : 359 - 367
  • [27] Influence of maxillary cortical bone thickness, implant design and implant diameter on stress around implants: A three-dimensional finite element analysis
    Okumura, Nobuaki
    Stegaroiu, Roxana
    Kitamura, Eriko
    Kurokawa, Kouichi
    Nomura, Shuichi
    JOURNAL OF PROSTHODONTIC RESEARCH, 2010, 54 (03) : 133 - 142
  • [28] Three dimensional finite element analysis of the stress distribution around the mandibular posterior implant during non-working movement according to the amount of cantilever
    Park, Ji-Man
    Kim, Hyun-Joo
    Park, Eun-Jin
    Kim, Myung-Rae
    Kim, Sun-Jong
    JOURNAL OF ADVANCED PROSTHODONTICS, 2014, 6 (05): : 361 - 371
  • [29] Comparison of stress distribution around all-on-four implants of different angulations and zygoma implants: a 7-model finite element analysis
    Tezerisener, Hueseyin Alican
    Ozalp, Oznur
    Altay, Mehmet Ali
    Sindel, Alper
    BMC ORAL HEALTH, 2024, 24 (01)
  • [30] Comparison of stress distribution around all-on-four implants of different angulations and zygoma implants: a 7-model finite element analysis
    Hüseyin Alican Tezerişener
    Öznur Özalp
    Mehmet Ali Altay
    Alper Sindel
    BMC Oral Health, 24