inter-implant distance;
dental implant;
peri-implant structure;
stress distribution;
3D finite elements analysis;
D O I:
10.1016/j.medengphy.2005.04.025
中图分类号:
R318 [生物医学工程];
学科分类号:
0831 ;
摘要:
Purpose: The aim of this study was to evaluate the effects of different inter-implant distances on stress distribution in the bone around the endosseous titanium implants under vertical, oblique and horizontal loads in the posterior mandibular edentulousim by finite element analysis (3D FEA). Materials and methods: 3D FEA models representing mandible and ITI (R) implant (Straumann, Waldenburg, Switzerland) were simulated. The distances in-between the units were set at 0.5, 1.0 and 2.0 cm. Vertical (V) 70 degrees N, 60 degrees oblique (BL) 35 degrees N in buccolingual direction and horizontal (MD) 14 degrees N in mesiodistal direction loads were applied to each of these designs. The principal stresses (tensile and compressive stress) on each model were calculated using MSC MARC finite element analyze solver software. Results: The tensile stress (P-max) values have been evaluated that they rose at the cervical region of buccal side when the inter-implant distances increased under V and BL loads and they diminished while the inter-implant distances decreased. In short inter-implant distances the compressive stress (P-min) has been presented with increased values and found at the lingual surface of the cervical region. Discussion: The results of this study indicated that the magnitude of the stress was influenced by complex factors such as the direction of loads and the distance between adjacent fixtures. The stress occurring around fixtures differs significantly with various types of inter-implant distance. Conclusion: The evaluation of tensile and compressive stresses for cortical and cancellous bone under V,(MD)-M-1 and BL loading conditions in aspect of inter-implant distance shows; the 1.0 cm of inter-implant distance is the optimum distance for two fixture implantation. (c) 2005 IPEM. Published by Elsevier Ltd. All rights reserved.
机构:
Fourth Mil Med Univ, Sch Stomatol, Dept Orthodont, Xian 710032, Peoples R ChinaFourth Mil Med Univ, Sch Stomatol, Dept Orthodont, Xian 710032, Peoples R China
Li, Tao
Hu, Kaijin
论文数: 0引用数: 0
h-index: 0
机构:
Fourth Mil Med Univ, Sch Stomatol, Dept Oral & Maxillofacial Surg, Xian 710032, Peoples R ChinaFourth Mil Med Univ, Sch Stomatol, Dept Orthodont, Xian 710032, Peoples R China
Hu, Kaijin
Cheng, Libo
论文数: 0引用数: 0
h-index: 0
机构:
Xi An Jiao Tong Univ, Sch Energy & Power Engn, Dept Fluid Machinery & Engn, Xian 710049, Peoples R ChinaFourth Mil Med Univ, Sch Stomatol, Dept Orthodont, Xian 710032, Peoples R China
Cheng, Libo
Ding, Yin
论文数: 0引用数: 0
h-index: 0
机构:
Fourth Mil Med Univ, Sch Stomatol, Dept Orthodont, Xian 710032, Peoples R ChinaFourth Mil Med Univ, Sch Stomatol, Dept Orthodont, Xian 710032, Peoples R China
Ding, Yin
Ding, Yuxiang
论文数: 0引用数: 0
h-index: 0
机构:
Fourth Mil Med Univ, Sch Stomatol, Dept Oral & Maxillofacial Surg, Xian 710032, Peoples R ChinaFourth Mil Med Univ, Sch Stomatol, Dept Orthodont, Xian 710032, Peoples R China
Ding, Yuxiang
Shao, Jinling
论文数: 0引用数: 0
h-index: 0
机构:
Fourth Mil Med Univ, Sch Stomatol, Dept Orthodont, Xian 710032, Peoples R ChinaFourth Mil Med Univ, Sch Stomatol, Dept Orthodont, Xian 710032, Peoples R China
Shao, Jinling
Kong, Liang
论文数: 0引用数: 0
h-index: 0
机构:
Fourth Mil Med Univ, Sch Stomatol, Dept Oral & Maxillofacial Surg, Xian 710032, Peoples R ChinaFourth Mil Med Univ, Sch Stomatol, Dept Orthodont, Xian 710032, Peoples R China
机构:
Univ Mississippi, Med Ctr, Biomed Mat Sci, Jackson, MS 39216 USA
Univ Alabama, Coll Engn, Tuscaloosa, AL USAUniv Mississippi, Med Ctr, Biomed Mat Sci, Jackson, MS 39216 USA
Wilkirson, Elizabeth
Chandran, Ravi
论文数: 0引用数: 0
h-index: 0
机构:
Univ Mississippi, Med Ctr, Oral Maxillofacial Surg & Pathol, Jackson, MS 39216 USAUniv Mississippi, Med Ctr, Biomed Mat Sci, Jackson, MS 39216 USA
Chandran, Ravi
Duan, Yuanyuan
论文数: 0引用数: 0
h-index: 0
机构:
Univ Mississippi, Med Ctr, Biomed Mat Sci, Jackson, MS 39216 USAUniv Mississippi, Med Ctr, Biomed Mat Sci, Jackson, MS 39216 USA