Effects of different inter-implant distances on the stress distribution around endosseous implants in posterior mandible: A 3D finite element analysis

被引:61
|
作者
Simsek, B
Erkmen, E
Yilmaz, D
Eser, A
机构
[1] Gazi Univ, Fac Dent, Dept Oral & Maxillofacial Surg, TR-06690 Ankara, Turkey
[2] Middle E Tech Univ, Dept Mech Engn, Ankara, Turkey
关键词
inter-implant distance; dental implant; peri-implant structure; stress distribution; 3D finite elements analysis;
D O I
10.1016/j.medengphy.2005.04.025
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose: The aim of this study was to evaluate the effects of different inter-implant distances on stress distribution in the bone around the endosseous titanium implants under vertical, oblique and horizontal loads in the posterior mandibular edentulousim by finite element analysis (3D FEA). Materials and methods: 3D FEA models representing mandible and ITI (R) implant (Straumann, Waldenburg, Switzerland) were simulated. The distances in-between the units were set at 0.5, 1.0 and 2.0 cm. Vertical (V) 70 degrees N, 60 degrees oblique (BL) 35 degrees N in buccolingual direction and horizontal (MD) 14 degrees N in mesiodistal direction loads were applied to each of these designs. The principal stresses (tensile and compressive stress) on each model were calculated using MSC MARC finite element analyze solver software. Results: The tensile stress (P-max) values have been evaluated that they rose at the cervical region of buccal side when the inter-implant distances increased under V and BL loads and they diminished while the inter-implant distances decreased. In short inter-implant distances the compressive stress (P-min) has been presented with increased values and found at the lingual surface of the cervical region. Discussion: The results of this study indicated that the magnitude of the stress was influenced by complex factors such as the direction of loads and the distance between adjacent fixtures. The stress occurring around fixtures differs significantly with various types of inter-implant distance. Conclusion: The evaluation of tensile and compressive stresses for cortical and cancellous bone under V,(MD)-M-1 and BL loading conditions in aspect of inter-implant distance shows; the 1.0 cm of inter-implant distance is the optimum distance for two fixture implantation. (c) 2005 IPEM. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:199 / 213
页数:15
相关论文
共 50 条
  • [1] Effects of Implant-Abutment Connection Type and Inter-Implant Distance on Inter-Implant Bone Stress and Microgap: Three-Dimensional Finite Element Analysis
    Matsuoka, Takashi
    Nakano, Tamaki
    Yamaguchi, Satoshi
    Ono, Shinji
    Watanabe, Shota
    Sato, Takumi
    Yatani, Hirofumi
    MATERIALS, 2021, 14 (09)
  • [2] Effects of inter-implant distance and implant length on the response to frontal traumatic force of two anterior implants in an atrophic mandible: three-dimensional finite element analysis
    Kan, B.
    Coskunses, F. M.
    Mutlu, I.
    Ugur, L.
    Meral, D. G.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2015, 44 (07) : 908 - 913
  • [3] Comparison of the rehabilitation of posterior atrophic edentulous mandible with different interforaminal implant placement concepts: a 3D finite element analysis
    Akca, B. S.
    Kucukkurt, S.
    JOURNAL OF OSSEOINTEGRATION, 2023, 15 (03) : 155 - 164
  • [4] Effect of vertical bone loss on stress distribution at the bone-implant interface around implants of varying diameters-an in silico 3D finite element analysis
    Gupta, Shipra
    Chopra, Priyanka
    Goyal, Parveen
    Jain, Ashish
    MATERIALS TODAY-PROCEEDINGS, 2021, 45 : 4581 - 4586
  • [5] Effects of all-on-four implant designs in mandible on implants and the surrounding bone: A 3-D finite element analysis
    Deste, G.
    Durkan, R.
    NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2020, 23 (04) : 456 - 463
  • [6] Optimum selection of the dental implant diameter and length in the posterior mandible with poor bone quality - A 3D finite element analysis
    Li, Tao
    Hu, Kaijin
    Cheng, Libo
    Ding, Yin
    Ding, Yuxiang
    Shao, Jinling
    Kong, Liang
    APPLIED MATHEMATICAL MODELLING, 2011, 35 (01) : 446 - 456
  • [7] Finite Element Analysis and Experimental Investigations on Stress Distribution of Dental Implants around Implant-Bone Interface
    Dhatrak, Pankaj
    Shirsat, Uddhav
    Sumanth, S.
    Deshmukh, Vijay
    MATERIALS TODAY-PROCEEDINGS, 2018, 5 (02) : 5641 - 5648
  • [8] Rehabilitation of Atrophic Posterior Maxilla with Pterygoid Implants: A 3D Finite Element Analysis
    Wilkirson, Elizabeth
    Chandran, Ravi
    Duan, Yuanyuan
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2021, 36 (03) : E51 - E62
  • [9] A 3D Finite Element Study for Stress Analysis in Bone Tissue Around Single Implants with Different Materials and Various Bone Qualities
    Zia Shamami, Darush
    Karimi, Alireza
    Beigzadeh, Borhan
    Haghpanahi, Mohammad
    Navidbakhsh, Mandi
    JOURNAL OF BIOMATERIALS AND TISSUE ENGINEERING, 2014, 4 (08) : 632 - 637
  • [10] The effect of thread design on stress distribution in a solid screw implant: a 3D finite element analysis
    Oğuz Eraslan
    Özgür İnan
    Clinical Oral Investigations, 2010, 14 : 411 - 416