Dual-energy Computed Tomography (DECT) in Renal Masses: Nonlinear versus Linear Blending

被引:33
作者
Ascenti, Giorgio [1 ]
Krauss, Bernhard [2 ]
Mazziotti, Silvio [1 ]
Mileto, Achille [1 ]
Settineri, Nicola [1 ]
Vinci, Sergio [1 ]
Donato, Rocco [1 ]
Gaeta, Michele [1 ]
机构
[1] Policlin G Martino, Dept Radiol Sci, I-98125 Messina, Italy
[2] Siemens AG, Healthcare Sect, Forchheim, Germany
关键词
Dual-energy CT; renal masses; linear blending; nonlinear blending; image quality; LOW-TUBE-VOLTAGE; HYPERVASCULAR LIVER-TUMORS; MULTIDETECTOR CT; IMAGE QUALITY; URIC-ACID; PHASE; DIFFERENTIATION; PHANTOM; REPAIR;
D O I
10.1016/j.acra.2012.05.010
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rational and Objectives: To investigate whether a nonlinear-blending algorithm improves tumor conspicuity and image quality in the evaluation of renal masses at dual-energy computed tomography (DECT) during nephrographic phase of enhancement. Materials and Methods: The Institutional Review Board approved this retrospective study from archival material from patients consenting to the use of medical records for research purposes. A retrospective review of contrast-enhanced abdominal DECT scans in 45 patients (mean age, 59.5 years; range, 24-84 years) was performed. DECT data were reconstructed using nonlinear and linear blending. A region of interest was located within tumors and adjacent normal parenchyma; attenuation differences and contrast-to-noise ratios (CNRs) were calculated for renal masses on nonlinear- and linear-blended images. The two datasets were subjectively compared in terms of tumor detection and image quality. An exact Wilcoxon's matched pairs signed rank and marginal homogeneity tests were used to test whether differences in attenuation, CNR, and subjective assessment were greater using nonlinear blending. Results: The mean difference in attenuation for renal masses and adjacent portion of renal parenchyma was 138.4 Hounsfield units +/- 28.9 SD using nonlinear blending, and 121.6 HU +/- 18.0 SD using linear blending (P < .001). Mean CNR was 12.6 +/- 2.5 SD using nonlinear blending, and 9.6 +/- 2.2 SD using 0.3 linear-blended (P < .001). No significant difference in tumor detection was observed between the two algorithms. Image quality was significantly better (P < .001) using nonlinear blending. Conclusion: Compared with standard linear blending, nonlinear-blending algorithm improves tumor conspicuity and image quality in renal masses at DECT evaluation during nephrographic phase of enhancement.
引用
收藏
页码:1186 / 1193
页数:8
相关论文
共 31 条
[1]   Pilot multi-reader study demonstrating potential for dose reduction in dual energy hepatic CT using non-linear blending of mixed kV image datasets [J].
Apel, Anja ;
Fletcher, Joel G. ;
Fidler, Jeff L. ;
Hough, David M. ;
Yu, Lifeng ;
Guimaraes, Luis S. ;
Bellemann, Matthias E. ;
McCollough, Cynthia H. ;
Holmes, David R., III ;
Eusemann, Christian D. .
EUROPEAN RADIOLOGY, 2011, 21 (03) :644-652
[2]   Dual-Source Dual-Energy CT Evaluation of Complex Cystic Renal Masses [J].
Ascenti, Giorgio ;
Mazziotti, Silvio ;
Mileto, Achille ;
Racchiusa, Sergio ;
Donato, Rocco ;
Settineri, Nicola ;
Gaeta, Michele .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (05) :1026-1034
[3]   Dual-Energy CT for Detection of Endoleaks After Endovascular Abdominal Aneurysm Repair: Usefulness of Colored Iodine Overlay [J].
Ascenti, Giorgio ;
Mazziotti, Silvio ;
Lamberto, Salvatore ;
Bottari, Antonio ;
Caloggero, Simona ;
Racchiusa, Sergio ;
Mileto, Achille ;
Scribano, Emanuele .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 196 (06) :1408-1414
[4]   Stone-Targeted Dual-Energy CT: A New Diagnostic Approach to Urinary Calculosis [J].
Ascenti, Giorgio ;
Siragusa, Carmelo ;
Racchiusa, Sergio ;
Ielo, Isidora ;
Privitera, Giambattista ;
Midili, Federica ;
Mazziotti, Silvio .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (04) :953-958
[5]   Renal Stone Assessment with Dual-Energy Multidetector CT and Advanced Postprocessing Techniques: Improved Characterization of Renal Stone Composition-Pilot Study [J].
Boll, Daniel T. ;
Patil, Neil A. ;
Paulson, Erik K. ;
Merkle, Elmar M. ;
Simmons, W. Neal ;
Pierre, Sean A. ;
Preminger, Glenn M. .
RADIOLOGY, 2009, 250 (03) :813-820
[6]   Abdominal Aorta: Evaluation with Dual-Source Dual-Energy Multidetector CT after Endovascular Repair of Aneurysms-Initial Observations [J].
Chandarana, Hersh ;
Godoy, Myrna C. B. ;
Vlahos, Ioannis ;
Graser, Anno ;
Babb, James ;
Leidecker, Christianne ;
Macari, Michael .
RADIOLOGY, 2008, 249 (02) :692-700
[7]   Iodine Quantification With Dual-Energy CT: Phantom Study and Preliminary Experience With Renal Masses [J].
Chandarana, Hersh ;
Megibow, Alec J. ;
Cohen, Benjamin A. ;
Srinivasan, Ramya ;
Kim, Danny ;
Leidecker, Christianne ;
Macari, Michael .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 196 (06) :W693-W700
[8]  
Eusemann C, 2008, DUAL ENERGY CT BEST
[9]   Dual-Energy and Dual-Source CT: Is There a Role in the Abdomen and Pelvis? [J].
Fletcher, Joel G. ;
Takahashi, Naoki ;
Hartman, Robert ;
Guimaraes, Luis ;
Huprich, James E. ;
Hough, David M. ;
Yu, Lifeng ;
McCollough, Cynthia H. .
RADIOLOGIC CLINICS OF NORTH AMERICA, 2009, 47 (01) :41-+
[10]   Identification of Intraarticular and Periarticular Uric Acid Crystals with Dual-Energy CT: Initial Evaluation [J].
Glazebrook, Katrina N. ;
Guimaraes, Luis S. ;
Murthy, Naveen S. ;
Black, David F. ;
Bongartz, Tim ;
Manek, Nisha J. ;
Leng, Shuai ;
Fletcher, Joel G. ;
McCollough, Cynthia H. .
RADIOLOGY, 2011, 261 (02) :516-524