Determination of venlafaxine in human plasma by high-performance liquid chromatography using cloud-point extraction and spectrofluorimetric detection

被引:76
作者
Qin, Xiang Yang [1 ]
Meng, Jin [2 ]
Li, Xiao Ye [1 ]
Zhou, Jun [1 ]
Sun, Xiao Li [1 ]
Wen, Ai Dong [3 ]
机构
[1] Fourth Mil Med Univ, Sch Pharm, Dept Chem, Xian 710032, Shanxi, Peoples R China
[2] Peoples Liberat Army Gen Hosp, Dept Pharm, Beijing 100853, Peoples R China
[3] Fourth Mil Med Univ, Xijing Hosp, Dept Pharm, Xian 710032, Shanxi, Peoples R China
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2008年 / 872卷 / 1-2期
关键词
venlafaxine; cloud-point extraction; high-performance liquid chromatography; Triton X-114; pharmacokinetics;
D O I
10.1016/j.jchromb.2008.06.052
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A new straightforward method based on cloud-point extraction (CPE) has been developed, optimized and validated for the determination of venlafaxine in human plasma by reversed-phase high-performance liquid chromatography with fluorescence detection. The non-ionic surfactant Triton X-114 (polyethylene glycol tert-octylphenyl ether) Was chosen as the extract solvent. Separation was obtained using a reversed-phase Diamonsil column (C-18, 250 mm x 4.6 mm I.D., 5 mu m) and a mobile phase composed of acetonitrile-phosphate buffer solution (pH 3.0)-triethylamine (33.5:66.5:0.4). Fluorescence detection was used (lambda(ex) 276 nm, lambda(em) 598 nm). Maprotiline was used as the internal standard. Under the optimum conditions, the linear range of venlafaxine in human plasma was 10-800 ng mL(-1) (r(2) = 0.9995). The limit of detection (LOD) was less than 2 ng mL(-1) (S/N = 3) and the limit of quantification (LOQ) was less than 10 ng mL(-1) (S/N = 10). The method Was Successfully applied for the evaluation of pharmacokinetic profiles of venlafaxine capsules in nine healthy volunteers. (c) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:38 / 42
页数:5
相关论文
共 36 条
[1]   Liquid chromatography-tandem mass spectrometry (LC-MS-MS) method for simultaneous determination of venlafaxine and its active metabolite O-desmethyl venlafaxine in human plasma [J].
Bhatt, J ;
Jangid, A ;
Venkatesh, G ;
Subbaiah, G ;
Singh, S .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 829 (1-2) :75-81
[2]   Surfactant cloud point extraction and preconcentration of organic compounds prior to chromatography and capillary electrophoresis [J].
Carabias-Martínez, R ;
Rodríguez-Gonzalo, E ;
Moreno-Cordero, B ;
Pérez-Pavón, JL ;
García-Pinto, C ;
Laespada, EF .
JOURNAL OF CHROMATOGRAPHY A, 2000, 902 (01) :251-265
[3]   An acid-induced phase cloud point separation approach using anionic surfactants for the extraction and preconcentration of organic compounds [J].
Casero, I ;
Sicilia, D ;
Rubio, S ;
Pérez-Bendito, D .
ANALYTICAL CHEMISTRY, 1999, 71 (20) :4519-4526
[4]   Simultaneous measurement of venlafaxine and its major metabolite, oxydesmethylvenlafaxine, in human plasma by high-performance liquid chromatography with coulometric detection and utilisation of solid-phase extraction [J].
Clement, EM ;
Odontiadis, J ;
Franklin, M .
JOURNAL OF CHROMATOGRAPHY B, 1998, 705 (02) :303-308
[5]   Nonionic surfactant mixtures:: a new cloud-point extraction approach for the determination of PAHs in seawater using HPLC with fluorimetric detection [J].
Delgado, B ;
Pino, V ;
Ayala, JH ;
González, V ;
Afonso, AM .
ANALYTICA CHIMICA ACTA, 2004, 518 (1-2) :165-172
[6]   Simultaneous determination of 3-nitro tyrosine, o-, m-, and p-tyrosine in urine samples by liquid chromatography-ultraviolet absorbance detection with pre-column cloud point extraction [J].
Du, M ;
Wu, W ;
Ercal, N ;
Ma, YF .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 803 (02) :321-329
[7]   A high-performance liquid chromatography method with photodiode-array UV detection for therapeutic drug monitoring of the nontricyclic antidepressant drugs [J].
Duverneuil, C ;
de la Grandmaison, GL ;
de Mazancourt, P ;
Alvarez, JC .
THERAPEUTIC DRUG MONITORING, 2003, 25 (05) :565-573
[8]   The use of micellar systems in the extraction and pre-concentration of organic pollutants in environmental samples [J].
Ferrera, ZS ;
Sanz, CP ;
Santana, CM ;
Rodríguez, JJS .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2004, 23 (07) :469-479
[9]   EVALUATION AND OPTIMIZATION OF THE FACTORS AFFECTING NONIONIC SURFACTANT-MEDIATED PHASE SEPARATIONS [J].
FRANKEWICH, RP ;
HINZE, WL .
ANALYTICAL CHEMISTRY, 1994, 66 (07) :944-954
[10]  
Garcia-Pinto C., 1994, ANAL CHEM, V66, P874