Development of a simple and sensitive HPLC-UV method for the simultaneous determination of cannabidiol and Δ9-tetrahydrocannabinol in rat plasma

被引:56
|
作者
Zgair, Atheer [1 ,2 ]
Wong, Jonathan C. M. [1 ]
Sabri, Akmal [1 ]
Fischer, Peter M. [1 ]
Barrett, David A. [1 ]
Constantinescu, Cris S. [3 ,4 ]
Gershkovich, Pavel [1 ]
机构
[1] Univ Nottingham, Sch Pharm, Nottingham NG7 2RD, England
[2] Univ Anbar, Coll Pharm, Anbar, Iraq
[3] Univ Nottingham, Div Clin Neurosci, Nottingham NG7 2RD, England
[4] Queens Med Ctr, Nottingham NG7 2UH, England
基金
英国惠康基金;
关键词
Cannabidiol; Delta(9)-Tetrahydrocannabinol; HPLC-UV; Rat plasma; Pharmacokinetics; PERFORMANCE LIQUID-CHROMATOGRAPHY; SOLID-PHASE EXTRACTION; IN-VITRO; MASS-SPECTROMETRY; ANIMAL-MODELS; HUMAN-BLOOD; DELTA-9-TETRAHYDROCANNABINOL; VIVO; 11-NOR-9-CARBOXY-THC; 11-HYDROXY-THC;
D O I
10.1016/j.jpba.2015.05.019
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
There has been increased interest in the medical use of cannabinoids in recent years, particularly in the predominant natural cannabinoids, cannabidiol (CBD) and Delta(9)-tetrahydrocannabinol (THC). The aim of the current study was to develop a sensitive and reliable method for the quantification of CBD and THC in rat plasma. A combination of protein precipitation using cold acetonitrile and liquid-liquid extraction using n-hexane was utilised to extract CBD and THC from rat plasma. Samples were then evaporated and reconstituted in acetonitrile and 30 mu L. was injected into an HPLC system. Separation was achieved using an ACE C18-PFP 150 mm x 4.6 mm, 3 mu m column at 55 C with isocratic elution using a mobile phase consisting of acetonitrile-water (62:38, v/v) at 1 mL/min for 20 min. Both cannabinoids, as well as the internal standard (4,4-dichlorodiphenyltrichloroethane, DDT) were detected at 220 nm. Our new method showed linearity in the range of 10-10,000 ng/mL and a lower limit of quantification (LLOQ) of 10 ng/mL for both cannabinoids, which is comparable to previously reported LC-MS/MS methods. Inter- and intra-day precision and accuracy were below 15% RSD and RE, respectively. To demonstrate the suitability of the method for in vivo studies in rats, the assay was applied to a preliminary pharmacokinetic study following IV bolus administration of 5 mg/kg CBD or THC. In conclusion, a simple, sensitive, and cost-efficient HPLC-UV method for the simultaneous determination of CBD and THC has been successfully developed, validated and applied to a pharmacokinetic study in rats. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:145 / 151
页数:7
相关论文
共 50 条
  • [1] Simple and sensitive HPLC-UV method for determination of bexarotene in rat plasma
    Lee, Jong Bong
    Zgair, Atheer
    Kim, Tae Hwan
    Kim, Min Gi
    Yoo, Sun Dong
    Fischer, Peter M.
    Gershkovich, Pavel
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2017, 1040 : 73 - 80
  • [2] A Simple and Sensitive HPLC-UV Method for the Determination of Swainsonine in Rat Plasma and its Application in a Pharmacokinetic Study
    Li, D. -L.
    Dong, C. -Y.
    Gao, Y.
    ARZNEIMITTELFORSCHUNG-DRUG RESEARCH, 2012, 62 (05): : 209 - 212
  • [3] A simple and sensitive HPLC-UV method for the determination of ponicidin in rat plasma and its application in a pharmacokinetic study
    Li, Xiaotian
    Hou, Wenjing
    Song, Jingjing
    Liu, Hongmin
    Song, Shumei
    Zhang, Lingchun
    Shi, Yingying
    BIOMEDICAL CHROMATOGRAPHY, 2011, 25 (03) : 362 - 366
  • [4] A Simple and Sensitive HPLC-UV Method for the Estimation of Ofloxacin in Plasma
    Hussain, Niaz
    Shah, Nisar Hussain
    Khurram Syed, Shahzada
    Rasool, Muhammad F.
    Nisar, Naveed
    Majeed, Abdul
    LATIN AMERICAN JOURNAL OF PHARMACY, 2021, 40 (11): : 2731 - 2734
  • [5] A Simple HPLC-UV Method for Ivosidenib Determination in Human Plasma
    Gando, Yoshito
    Yasu, Takeo
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2023, 62 (06) : 580 - 584
  • [6] A simple HPLC-UV method for the determination of lacosamide in human plasma
    Kestelyn, C.
    Lastelle, M.
    Higuet, N.
    Dell'Aiera, S.
    Staelens, L.
    Boulanger, P.
    Boekens, H.
    Smith, S.
    BIOANALYSIS, 2011, 3 (22) : 2515 - 2522
  • [7] A simple HPLC-UV method for the determination of ciprofloxacin in human plasma
    Vella, Janis
    Busuttil, Francesca
    Bartolo, Nicolette Sammut
    Sammut, Carmel
    Ferrito, Victor
    Serracino-Inglott, Anthony
    Azzopardi, Lilian M.
    LaFerla, Godfrey
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2015, 989 : 80 - 85
  • [8] Development of rapid and sensitive method for determination of mycophenolic acid in human plasma by HPLC-UV
    Pawinski, T.
    Szlaska, I
    Wakulicz, A.
    THERAPEUTIC DRUG MONITORING, 2011, 33 (04) : 545 - 545
  • [9] A Simple, Sensitive and Economical HPLC-UV Method for Determination of Favipiravir in Microsamples of Rat Plasma and its Application in a Pharmacokinetic Study
    Aguilar Carrasco, Jose Carlos
    Gutierrez-Lopez, Alberto
    Daniela Cruz-Cruz, Marisol
    Ignacio Aguilar-Carrasco, Jose
    Pantic, Ivan
    LATIN AMERICAN JOURNAL OF PHARMACY, 2021, 40 (10): : 2431 - 2438
  • [10] A simple and rapid HPLC-UV method for the determination of retigabine in human plasma
    Franco, Valentina
    Baruffi, Katia
    Gatti, Giuliana
    Marchiselli, Roberto
    Fattore, Cinzia
    Canevini, Maria Paola
    Crema, Francesca
    Perucca, Emilio
    BIOMEDICAL CHROMATOGRAPHY, 2018, 32 (05)