Using the American College of Radiology Dose Index Registry to Evaluate Practice Patterns and Radiation Dose Estimates of Pediatric Body CT

被引:15
|
作者
Wildman-Tobriner, Benjamin [1 ]
Strauss, Keith J. [2 ]
Bhargavan-Chatfield, Mythreyi [3 ]
Kadom, Nadja [4 ]
Vock, Peter [5 ]
Applegate, Kimberly E. [6 ]
Frush, Donald P. [1 ]
机构
[1] Duke Univ, Dept Radiol, 2301 Erwin Rd, Durham, NC 27710 USA
[2] Cincinnati Childrens Hosp Med Ctr, Dept Radiol, Cincinnati, OH 45229 USA
[3] Amer Coll Radiol, Reston, VA USA
[4] Emory Univ, Sch Med, Dept Radiol & Imaging Sci, Atlanta, GA USA
[5] Univ Bern, Univ Hosp, Dept Radiol, Bern, Switzerland
[6] Univ Kentucky, Lexington, KY USA
关键词
children; CT; diagnostic reference level; dose index registry; pediatrics; COMPUTED-TOMOGRAPHY; IONIZING-RADIATION; UNITED-STATES; EXPOSURE; CANCER; POPULATION; CAMPAIGN; PROGRAM; RISK;
D O I
10.2214/AJR.17.18122
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. Imaging registries afford opportunities to study large, heterogeneous populations. The purpose of this study was to examine the American College of Radiology CT Dose Index Registry (DIR) for dose-related demographics and metrics of common pediatric body CT examinations. MATERIALS AND METHODS. Single-phase CT examinations of the abdomen and pelvis and chest submitted to the DIR over a 5-year period (July 2011-June 2016) were evaluated (head CT frequency was also collected). CT examinations were stratified into five age groups, and examination frequency was determined across age and sex. Standard dose indexes (volume CT dose index, dose-length product, and size-specific dose estimate) were categorized by body part and age. Contributions to the DIR were also categorized by region and practice type. RESULTS. Over the study period 411,655 single-phase pediatric examinations of the abdomen and pelvis, chest, and head, constituting 5.7% of the total (adult and pediatric) examinations, were submitted to the DIR. Head CT was the most common examination across all age groups. The majority of all scan types were performed for patients in the second decade of life. Dose increased for all scan types as age increased; the dose for abdominopelvic CT was the highest in each age group. Even though the DIR was queried for single-phase examinations only, as many as 32.4% of studies contained multiple irradiation events. When these additional scans were included, the volume CT dose index for each scan type increased. Among the studies in the DIR, 99.8% came from institutions within the United States. Community practices and those that specialize in pediatrics were nearly equally represented. CONCLUSION. The DIR provides valuable information about practice patterns and dose trends for pediatric CT and may assist in establishing diagnostic reference levels in the pediatric population.
引用
收藏
页码:641 / 647
页数:7
相关论文
共 50 条
  • [21] Comparison of effective radiation doses from X-ray, CT, and PET/CT in pediatric patients with neuroblastoma using a dose monitoring program
    Kim, Yeun Yoon
    Shin, Hyun Joo
    Kim, Myung-Joon
    Lee, Mi-Jung
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2016, 22 (04): : 390 - 394
  • [22] Pediatric CT Dose Reduction for Suspected Appendicitis: A Practice Quality Improvement Project Using Artificial Gaussian Noise-Part 2, Clinical Outcomes
    Callahan, Michael J.
    Anandalwar, Seema P.
    MacDougall, Robert D.
    Stamoulis, Catherine
    Kleinman, Patricia L.
    Rangel, Shawn J.
    Bachur, Richard G.
    Taylor, George A.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 204 (03) : 636 - 644
  • [23] Pediatric CT Dose Reduction for Suspected Appendicitis: A Practice Quality Improvement Project Using Artificial Gaussian Noise-Part I, Computer Simulations
    Callahan, Michael J.
    Kleinman, Patricia L.
    Strauss, Keith J.
    Bandos, Andriy
    Taylor, George A.
    Tsai, Andy
    Kleinman, Paul K.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 204 (01) : W86 - W94
  • [24] Age- and gender-specific estimates of cumulative CT dose over 5 years using real radiation dose tracking data in children
    Eunsol Lee
    Hyun Woo Goo
    Jae-Yeong Lee
    Pediatric Radiology, 2015, 45 : 1282 - 1292
  • [25] Evaluation of pediatric malignancies using total-body PET/CT with half-dose [18F]-FDG
    Chen, Wanqi
    Liu, Lei
    Li, Yinghe
    Li, Shatong
    Li, Zhijian
    Zhang, Weiguang
    Zhang, Xu
    Wu, Runze
    Hu, Debin
    Sun, Hongyan
    Zhou, Yun
    Fan, Wei
    Zhao, Yumo
    Zhang, Yizhuo
    Hu, Yingying
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2022, 49 (12) : 4145 - 4155
  • [26] Comparison of radiation dose estimates, image noise, and scan duration in pediatric body imaging for volumetric and helical modes on 320-detector CT and helical mode on 64-detector CT
    Johnston, Jennifer H.
    Podberesky, Daniel J.
    Yoshizumi, Terry T.
    Angel, Erin
    Toncheva, Greta
    Larson, David B.
    Egelhoff, John C.
    Anderson-Evans, Colin
    Nguyen, Giao B.
    Barelli, Alessandra
    Alsip, Christopher
    Salisbury, Shelia R.
    Frush, Donald P.
    PEDIATRIC RADIOLOGY, 2013, 43 (09) : 1117 - 1127
  • [27] Validation of Adult Relative Radiation Levels Using the ACR Dose Index Registry: Report of the ACR . Appropriateness Criteria Radiation Exposure Subcommittee
    Jordan, David W.
    Becker, Murray D.
    Brady, Samuel
    Keenan, Mary Ann
    Rosen, Max P.
    Sengupta, Debapriya
    Strauss, Keith J.
    Cody, Dianna D.
    JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2019, 16 (02) : 236 - 239
  • [28] Is It Better to Enter a Volume CT Dose Index Value before or after Scan Range Adjustment for Radiation Dose Optimization of Pediatric Cardiothoracic CT with Tube Current Modulation?
    Goo, Hyun Woo
    KOREAN JOURNAL OF RADIOLOGY, 2018, 19 (04) : 692 - 703
  • [29] Reduction in radiation exposure in cardiovascular computed tomography imaging: results from the PROspective multicenter registry on radiaTion dose Estimates of cardiac CT angIOgraphy iNdaily practice in 2017 (PROTECTION VI)
    Stocker, Thomas J.
    Deseive, Simon
    Leipsic, Jonathon
    Hadamitzky, Martin
    Chen, Marcus Y.
    Rubinshtein, Ronen
    Heckner, Mathias
    Bax, Jeroen J.
    Fang, Xiang-Ming
    Grove, Erik
    Lesser, John
    Maurovich-Horvat, Pal
    Otton, James
    Shin, Sanghoon
    Pontone, Gianluca
    Marques, Hugo
    Chow, Benjamin
    Nomura, Cesar H.
    Tabbalat, Ramzi
    Schmermund, Axel
    Kang, Joon-Won
    Naoum, Christopher
    Atkins, Melany
    Martuscelli, Eugenio
    Massberg, Steffen
    Hausleiter, Joerg
    EUROPEAN HEART JOURNAL, 2018, 39 (41) : 3715 - 3723
  • [30] Estimating Effective Dose of Radiation From Pediatric Cardiac CT Angiography Using a 64-MDCT Scanner: New Conversion Factors Relating Dose-Length Product to Effective Dose
    Trattner, Sigal
    Chelliah, Anjali
    Prinsen, Peter
    Ruzal-Shapiro, Carrie B.
    Xu, Yanping
    Jambawalikar, Sachin
    Amurao, Maxwell
    Einstein, Andrew J.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2017, 208 (03) : 585 - 594