In-situ X-ray tomography of wear - A feasibility study

被引:6
|
作者
Aleksejev, Jure [1 ]
Lim, Yijun [2 ]
Huber, John [1 ]
Hofmann, Felix [1 ]
Marrow, James [2 ]
机构
[1] Univ Oxford, Dept Engn Sci, Parks Rd, Oxford OX1 3PJ, England
[2] Univ Oxford, Dept Mat, Parks Rd, Oxford OX1 3PH, England
基金
欧洲研究理事会; 英国工程与自然科学研究理事会;
关键词
X-ray tomography; Wear; Debris bed; Real area of contact; FRETTING WEAR; FINITE-ELEMENT; CONTACT; SURFACE; DAMAGE; TEMPERATURE; SIMULATION; RESISTANCE; BEHAVIORS; EVOLUTION;
D O I
10.1016/j.triboint.2020.106355
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Wear experiments using annular contacts were carried out to investigate the possibility of imaging wear scars and wear debris beds in-situ. Samples made of 6082T6 aluminium alloy were subjected to unidirectional wear under different conditions with the sample elements then locked in contact to preserve the end-of-wear condition. Post-wear 3D morphology was successfully imaged in-situ using X-ray tomography, with total depth of the wear scar, surface primary-profile roughness and real area of contact also obtained. This study is a proof-of-concept, illustrating the utility of tomography for studying wear, without the need to disassemble the contact or disturb the debris bed and serves as a starting point for a new approach to the investigation of wear phenomena.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] In-situ X-ray absorption spectroscopy study of metal/water interfaces
    Wu, Chenghao
    Velasco-Velez, Juan J.
    Fang, Haitao
    Guo, Jinghua
    Salmeron, Miquel B.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2014, 248
  • [42] In-situ characterization of liquids at high pressure combining X-ray tomography, X-ray diffraction and X-ray absorption using the white-beam station of PSICHE
    Itie, J-P.
    Henry, L.
    Guignot, N.
    King, A.
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2022, 78 : E638 - E638
  • [43] Limited-angle x-ray luminescence tomography: methodology and feasibility study
    Carpenter, C. M.
    Pratx, G.
    Sun, C.
    Xing, L.
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (12): : 3487 - 3502
  • [44] Polymer gel dosimetry using x-ray computed tomography: a feasibility study
    Hilts, M
    Audet, C
    Duzenli, C
    Jirasek, A
    PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (09): : 2559 - 2571
  • [45] X-Ray Luminescence Computed Tomography via Selective Excitation: A Feasibility Study
    Pratx, Guillem
    Carpenter, Colin M.
    Sun, Conroy
    Xing, Lei
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2010, 29 (12) : 1992 - 1999
  • [46] Feasibility study of Compton cameras for x-ray fluorescence computed tomography with humans
    Vernekohl, Don
    Ahmad, Moiz
    Chinn, Garry
    Xing, Lei
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (24): : 8521 - 8540
  • [47] X-ray Elastography: A Feasibility Study
    Kim, Gyu W.
    Han, Byung H.
    Cho, Min H.
    Lee, Soo Y.
    2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 3513 - 3516
  • [48] Analysis of Crack Patterns in Drying Corn Starch by in-situ Radiography and X-ray Computer Tomography
    H.-A. Crostack
    J. Nellesen
    G. Fischer
    M. Hofmann
    H.-G. Rademacher
    W. Tillmann
    Experimental Mechanics, 2012, 52 : 917 - 932
  • [49] In-situ X-ray tomography on permeability evolution of C/SiC porous ceramic for hypersonic vehicles
    Zhang, Bo
    Huang, Haiming
    Wu, Shengchuan
    Li, Weijie
    Huang, Jie
    Lin, Andi
    Wu, Qian
    Liu, Yuexun
    Xiao, Tiqiao
    CERAMICS INTERNATIONAL, 2021, 47 (19) : 27770 - 27777
  • [50] Observation of microstructure change during freeze-drying by in-situ X-ray Computed Tomography
    Nakagawa, K.
    Tamiya, S.
    Sakamoto, S.
    Do, G.
    Kono, S.
    Ochiai, T.
    IDS'2018: 21ST INTERNATIONAL DRYING SYMPOSIUM, 2018, : 935 - 942