Prefabricated epoxy-coated reinforcement is used increasingly in reinforced concrete construction in which high corrosion resistance is required. It is well established that epoxy coating reduces bond strength between reinforcement and concrete, and some tests have found that bond strength decreases as coating thickness increases. For prefabricated epoxy-coated reinforcement, it can be difficult to maintain coating thicknesses within required tolerances 175 to 300 fan. Beam-end tests were carried out on bars without coating, bars with green epoxy coating (203 fan coating thickness), and prefabricated (gray) epoxy coating (203 to 508 mu m coating thickness). Tests showed that epoxy coating reduces bond strength, with similar reductions for green and gray coatings. In some cases, bond strength decreased with increasing coating thickness; however, for the range of thicknesses investigated, the reduction factor of current building codes was found to be conservative.
机构:
Cent Res Inst Bldg & Construct Co Ltd, MCC Grp, Beijing 100088, Peoples R China
Tianjin Univ, Sch Civil Engn, Tianjin 300072, Peoples R China
Gansu Sci & Ind Construct Grp Co Ltd, Lanzhou 730200, Peoples R ChinaCent Res Inst Bldg & Construct Co Ltd, MCC Grp, Beijing 100088, Peoples R China
Ma, Zhangyong
Yue, Qingrui
论文数: 0引用数: 0
h-index: 0
机构:
Cent Res Inst Bldg & Construct Co Ltd, MCC Grp, Beijing 100088, Peoples R ChinaCent Res Inst Bldg & Construct Co Ltd, MCC Grp, Beijing 100088, Peoples R China
Yue, Qingrui
Chen, Zhihua
论文数: 0引用数: 0
h-index: 0
机构:
Tianjin Univ, Sch Civil Engn, Tianjin 300072, Peoples R ChinaCent Res Inst Bldg & Construct Co Ltd, MCC Grp, Beijing 100088, Peoples R China