Bond strength of prefabricated epoxy-coated reinforcement

被引:1
|
作者
De Anda, Liliana [1 ]
Courtier, Camille
Moehle, Jack P.
机构
[1] Degenkolb Engineers, San Diego, CA USA
[2] Ecole Natl Ponts & Chaussees, Paris, France
[3] Univ Calif Berkeley, Pacific Earthquake Engn Res Ctr, Berkeley, CA USA
关键词
bars; bond; epoxy; reinforcement; testing;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Prefabricated epoxy-coated reinforcement is used increasingly in reinforced concrete construction in which high corrosion resistance is required. It is well established that epoxy coating reduces bond strength between reinforcement and concrete, and some tests have found that bond strength decreases as coating thickness increases. For prefabricated epoxy-coated reinforcement, it can be difficult to maintain coating thicknesses within required tolerances 175 to 300 fan. Beam-end tests were carried out on bars without coating, bars with green epoxy coating (203 fan coating thickness), and prefabricated (gray) epoxy coating (203 to 508 mu m coating thickness). Tests showed that epoxy coating reduces bond strength, with similar reductions for green and gray coatings. In some cases, bond strength decreased with increasing coating thickness; however, for the range of thicknesses investigated, the reduction factor of current building codes was found to be conservative.
引用
收藏
页码:226 / 234
页数:9
相关论文
共 50 条