Synthesis, characterization and analytical application of Zn(II)-imprinted polymer as an efficient solid-phase extraction technique for trace determination of zinc ions in food samples

被引:67
作者
Behbahani, Mohammad [1 ]
Salarian, Mani [2 ]
Bagheri, Akbar [1 ]
Tabani, Hadi [1 ]
Omidi, Fariborz [3 ]
Fakhari, Alireza [1 ]
机构
[1] Shahid Beheshti Univ, Dept Chem, GC, Tehran 1983963113, Iran
[2] Georgia State Univ, Dept Chem, Atlanta, GA 30303 USA
[3] Univ Tehran Med Sci, Sch Publ Hlth, Dept Occupat Hlth, Tehran, Iran
关键词
Ion imprinted polymer; Copolymerization; Zinc; Solid-phase extraction; Preconcentration; Food analysis; Food Composition; Flame atomic absorption spectrometry; Food safety; Metal contamination levels in food; FLOW-INJECTION PRECONCENTRATION; EXPERIMENTAL-DESIGN; IMPRINTED POLYMER; WATER SAMPLES; METAL-IONS; COPPER; OPTIMIZATION; SORBENT; CU(II); FISH;
D O I
10.1016/j.jfca.2013.10.003
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
Zinc imprinted polymer (Zn(II)-IIP) as a solid-phase extraction technique was applied for preconcentration and determination of zinc in environmental and food samples by FAAS. Zn(II)-IIP was synthesized by copolymerization of 2-vinylpyridine as the functional monomer, ethylene glycol dimethacrylate (EGDMA) as the cross-linker, 2,2-azobisisobutyronitrile as the initiator, Zn(NO3)(2) as the template ion, diphenylcarbazone as the ligand, and methanol/dichloromethane (50:50) as the solvent. The synthesized polymer particles were characterized by thermogravimetry analysis (TGA), differential thermal analysis (DTA), scanning electron microscopy (SEM), Fourier transform infrared spectrometry (FT-IR), and X-ray diffraction (XRD). The optimization process was carried out using the central composite design (CCD). With this design, the optimum conditions for the adsorption step were 6.6, 30 mg, and 23 min, for pH, mass of polymer and adsorption time respectively, and for desorption step the optimal conditions were 14 mL, 12% (v/v), and 23 min, for volume of eluent, concentration of eluent, and desorption time, respectively. Under the optimized conditions, the detection limit of the proposed method was found to be 0.15 mu g L-1, while the relative standard deviation (RSD) for 10 replicate measurements was calculated to be 2.8%. Therefore the introduced selective solid phase extraction method can be used as a reliable technique for selective and sensitive trace detection of zinc in different food matrixes, and the reliability of the proposed solid phase extraction technique was established by the analysis of standard reference materials. (C) 2013 Elsevier Inc. All rights reserved.
引用
收藏
页码:81 / 89
页数:9
相关论文
共 50 条
[21]   Selective Solid-Phase Extraction and Trace Monitoring of Lead Ions in Food and Water Samples Using New Lead-Imprinted Polymer Nanoparticles [J].
Mohammad Behbahani ;
Parmoon Ghareh Hassanlou ;
Mostafa M. Amini ;
Hamid Reza Moazami ;
Hamid Sadeghi Abandansari ;
Akbar Bagheri ;
Salman Hassan Zadeh .
Food Analytical Methods, 2015, 8 :558-568
[22]   Preparation and Application of Nanostructure Ion-Imprinted Polymer for Selective Solid-Phase Extraction of Pb Ions in Water, Hair, and Food Samples [J].
Soltani, Maryam Dehghani ;
Taher, Mohammad Ali ;
Behzadi, Mansoureh .
JOURNAL OF AOAC INTERNATIONAL, 2016, 99 (05) :1363-1369
[23]   Synthesis, characterization, and application of novel Zn(II)-ionic imprinted polymer for preconcentration of Zn(II) ions from aqueous solution [J].
Wirawan, T. ;
Supriyanto, G. ;
Soegianto, A. .
12TH JOINT CONFERENCE ON CHEMISTRY, 2018, 349
[24]   Application of SBA-15/Diphenyl Carbazon/SDS Nanocomposite as Solid-Phase Extractor for Simultaneous Determination of Cu(II) and Zn(II) Ions [J].
Mirabi, Ali ;
Rad, Ali Shokuhi ;
Divsalar, Faranak ;
Karimi-Maleh, Hassan .
ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2018, 43 (07) :3547-3556
[25]   Synthesis, characterization and application of a novel ion-imprinted polymer based voltammetric sensor for selective extraction and trace determination of cobalt (II) ions [J].
Torkashvand, M. ;
Gholivand, M. B. ;
Azizi, R. .
SENSORS AND ACTUATORS B-CHEMICAL, 2017, 243 :283-291
[26]   Selective solid-phase extraction using molecular imprinted polymer sorbent for the analysis of Florfenicol in food samples [J].
Sadeghi, Susan ;
Jahani, Moslem .
FOOD CHEMISTRY, 2013, 141 (02) :1242-1251
[27]   Synthesis and application of surface-imprinted activated carbon sorbent for solid-phase extraction and determination of copper (II) [J].
Li, Zhenhua ;
Li, Jingwen ;
Wang, Yanbin ;
Wei, Yajun .
SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2014, 117 :422-427
[28]   Synthesis and application of vinylpyridine containing ion-imprinted copolymer gel microbeads for Cu(II) solid-phase extraction [J].
Dakova, Ivanka ;
Karadjova, Irina ;
Georgieva, Ventsislava ;
Georgiev, George .
JOURNAL OF SEPARATION SCIENCE, 2012, 35 (20) :2805-2812
[29]   Selective Determination of Chloramphenicol in Milk Samples by the Solid-Phase Extraction Based on Dummy Molecularly Imprinted Polymer [J].
Zhao, Fengnian ;
She, Yongxin ;
Zhang, Chao ;
Wang, Shanshan ;
Du, Xinwei ;
Jin, Fen ;
Jin, Maojun ;
Shao, Hua ;
Zheng, Lufei ;
Wang, Jing .
FOOD ANALYTICAL METHODS, 2017, 10 (07) :2566-2575
[30]   Synthesis and application of an oxytetracycline imprinted polymer for the solid-phase extraction of tetracycline antibiotics [J].
Caro, E ;
Marcé, RM ;
Cormack, PAG ;
Sherrington, DC ;
Borrull, F .
ANALYTICA CHIMICA ACTA, 2005, 552 (1-2) :81-86